bioRxiv ScienceSearch

SEARCH · bioRxiv Science

Results for “Bioengineering”

Search indexed bioRxiv preprints in genomics, neuroscience, cell biology and bioinformatics. Read source abstracts and check manuscript versions; preprints are not peer reviewed.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Single-cell integrative analysis of CAR-T cell activation reveals a predominantly TH1/TH2 mixed response independent of differentiation

We present the first comprehensive portrait of single-cell level transcriptional and cytokine signatures of anti-CD19 4-1BB/CD28/CD3{zeta} CAR-T cells upon antigen-specific stimulation. Both CD4+ helper and CD8+ cytotoxic CAR-T cells are equally effective in directly killing target tumor cells and their cytotoxic activity is associated with the elevation of a range of TH1 and TH2 signature cytokines (e.g., IFN{gamma}, TNF, IL5, and IL13), as confirmed by the expression of master transcription factors TBX21 (T-bet) and GATA3. However, rather than conforming to stringent TH1 or TH2 subtypes, single-cell analysis reveals that the predominant response is a highly mixed TH1/TH2 function in the same cell and the regulatory T cell (Treg) activity, although observed in a small fraction of activated cells, emerges from this hybrid TH1/TH2 population. GM-CSF is produced from the majority of cells regardless of the polarization states, further contrasting CAR-T to classic T cells. Surprisingly, the cytokine response is minimally associated with differentiation status although all major differentiation subsets such as naive, central memory, effector memory and effector are detected. All these suggest that the activation of CAR-engineered T cells is a canonical process that leads to a highly mixed response combining both type 1 and type 2 cytokines together with GMCSF, supporting the notion that polyfunctional CAR-T cells correlate with objective response of patients in clinical trials. This work provides new insights to the mechanism of CAR activation and implies the necessity for cellular function assays to characterize the quality of CAR-T infusion products and monitor therapeutic responses in patients.

bioengineering

Novel diamond shuttle to deliver flexible bioelectronics with reduced tissue compression

The ability to deliver flexible biosensors through the toughest membranes of the central and peripheral nervous system is an important challenge in neuroscience and neural engineering. Bioelectronic devices implanted through dura mater and thick epineurium would ideally create minimal compression and acute damage as they reach the neurons of interest. We demonstrate that a three-dimensional diamond shuttle can be easily made with a vertical support to deliver ultra-compliant polymer microelectrodes (4.5 m thick) in-vivo through dura mater and thick epineurium. The diamond shuttle has 54% less cross-sectional area than an equivalently stiff silicon shuttle, which we simulated will result in a 37% reduction in blood vessel damage. We also discovered that higher frequency oscillation of the shuttle (200 Hz) significantly reduced tissue compression regardless of the insertion speed, while slow speeds also independently reduced tissue compression. Insertion and recording performance are demonstrated in rat and feline models, but the large design space of these tools are suitable for research in a variety of animal models and nervous system targets.

bioengineering

Soleus muscle weakness in Cerebral Palsy: muscle architecture revealed with Diffusion Tensor Imaging

Cerebral palsy (CP) is associated with movement disorders and reduced muscle size. This latter phenomenon has been observed by computing muscle volumes from conventional MRI, with most studies reporting significantly reduced volumes in leg muscles. This indicates impaired muscle growth, but without knowing muscle fiber orientation, it is not clear whether muscle growth in CP is impaired in the along-fiber direction (indicating shortened muscles and limited range of motion) or the cross-fiber direction (indicating weak muscles and impaired strength). Using Diffusion Tensor Imaging (DTI) we can determine muscle fiber orientation and construct 3D muscle architectures to examine along-fiber length and cross-sectional area separately. Such an approach has not been undertaken in CP. Here, we use advanced DTI sequences with fast imaging times to capture fiber orientations in the soleus muscle of children with CP and age-matched, able-bodied controls. Physiological cross sectional areas (PCSA) were reduced (37 {+/-} 11%) in children with CP compared to controls, indicating impaired muscle strength. Along-fiber muscle lengths were not different between groups, but we observed large variance in length within CP group. This study is the first to demonstrate functional strength deficits using DTI and implicates impaired cross-sectional muscle growth in children with cerebral palsy.

bioengineering

Open channel droplet-based microfluidics

Droplet-based microfluidics enables compartmentalization and controlled manipulation of small volumes. Open microfluidics provides increased accessibility, adaptability, and ease of manufacturing compared to closed microfluidic platforms. Here, we begin to build a toolbox for the emerging field of open channel droplet-based microfluidics, combining the ease of use associated with open microfluidic platforms with the benefits of compartmentalization afforded by droplet-based microfluidics. We develop fundamental microfluidic features to control droplets flowing in an immiscible carrier fluid within open microfluidic systems. Our systems use capillary flow to move droplets and carrier fluid through open channels and are easily fabricated through 3D printing, micromilling, or injection molding; further, droplet generation can be accomplished by simply pipetting into the open channel. We demonstrate droplet incubation and transport for downstream experimentation and tunable droplet splitting in open channels driven by capillary flow. Potential applications of our toolbox for droplet manipulation in open channels include cell culture and analysis, on-chip microscale reactions, and reagent delivery.

bioengineering

OrgaQuant: Intestinal Organoid Localization and Quantification Using Deep Convolutional Neural Networks

Organoid cultures are proving to be powerful in vitro models that closely mimic the cellular constituents of their native tissue. The organoids are typically expanded and cultured in a 3D environment using either naturally derived or synthetic extracellular matrices. Assessing the morphology and growth characteristics of these cultures has been difficult due to the many imaging artifacts that accompany the corresponding images. Unlike single cell cultures, there are no reliable segmentation techniques that allow for the localization and quantification of organoids in their 3D culture environment. Here we describe OrgaQuant, a deep convolutional neural network implementation that can locate and quantify the size distribution of intestinal organoids in brightfield images. OrgaQuant is an end-to-end trained neural network that requires no parameter tweaking, thus it can be fully automated to analyze thousands of images with no user intervention. To develop OrgaQuant we created a unique dataset of manually annotated intestinal organoid images and trained an object detection pipeline using TensorFlow. We have made the dataset, trained model and inference scripts publically available along with detailed usage instructions.

bioengineering

Anemia Diagnosis on a Simple Paper-based Assay

In developing countries, the maternal and neonatal mortality rate is often affected by prenatal period anemia, a preventable and ubiquitous impairment attributed due to low hemoglobin (Hgb) concentration. We report the development of a simple, frugal (~ 0.02 $ per test), rapid and high fidelity paper-based colorimetric microfluidic device for point-of-care (POC) detection of anemia. We validate our findings with 32 blood samples collected from different patients covering a wide spectrum of anemia and subsequently, compare with standard pathological results measured using a hematology analyzer. POC based Hgb estimates are correlated with the pathological gold standard estimates of Hgb levels (r = 0.909), and the POC test method yielded similar sensitivity and specificity for detecting mild anemia (n = 8) (<11 g/dl) (sensitivity: 87.5%, specificity: 100 %) and for severe anemia (n = 3) (<7 g/dl) (sensitivity: 100 %, specificity: 100 %). The estimated Hgb levels are, within 1.5 g/dl from the pathological estimate, for 91 % of the blood samples. Results demonstrate the elevated efficacy and viability of this POC colorimetric diagnostic test, in comparison to the state-of-the-art complex and expensive diagnostic tests for anemia detection.

bioengineering

Fast, volumetric live-cell imaging using high-resolution light-field microscopy

Visualizing diverse anatomical and functional traits that span many spatial scales with high spatio-temporal resolution provides insights into the fundamentals of living organisms. Light-field microscopy (LFM) has recently emerged as a scanning-free, scalable method that allows for high-speed, volumetric functional brain imaging. Given those promising applications at the tissue level, at its other extreme, this highly-scalable approach holds great potential for observing structures and dynamics in single-cell specimens. However, the challenge remains for current LFM to achieve subcellular level, near-diffraction-limited 3D spatial resolution. Here, we report high-resolution LFM (HR-LFM) for live-cell imaging with a resolution of 300-700 nm in all three dimensions, an imaging depth of several micrometers, and a volume acquisition time of milliseconds. We demonstrate the technique by imaging various cellular dynamics and structures and tracking single particles. The method may advance LFM as a particularly useful tool for understanding biological systems at multiple spatio-temporal levels.

bioengineering

Microplate Assay for Denatured Collagen using CollagenHybridizing Peptides

The purpose of this study was to develop a microplate assay for quantifying denatured collagen by measuring the fluorescence of carboxyfluorescein bound collagen hybridizing peptides (F-CHP). We have shown that F-CHP binds selectively with denatured collagen, and that mechanical overload of tendon fascicles causes collagen denaturation. Proteinase K was used to homogenize tissue samples after F-CHP staining, allowing fluorescence measurement using a microplate reader. We compared our new assay to our previous image analysis method and the trypsin-hydroxyproline assay, which is the only other available method to directly quantify denatured collagen. Relative quantification of denatured collagen was performed in rat tail tendon fascicles subjected to incremental tensile overload, and normal and ostoeoarthritic guinea pig cartilage. In addition, the absolute amount of denatured collagen was determined in rat tail tendon by correlating F-CHP fluorescence with percent denatured collagen as determined by the trypsin-hydroxyproline assay. Rat tail tendon fascicles stretched to low strains (<7.5%) exhibited minimal denature collagen, but values rapidly increased at medium strains (7.5-10.5%) and plateaued at high strains ([&ge;]12%). Osteoarthritic cartilage had higher F-CHP fluorescence than healthy cartilage. Both of these outcomes are consistent with previous studies. With the calibration curve, the microplate assay was able to absolutely quantify denatured collagen in mechanically damaged rat tail tendon fascicles as reliably as the trypsin-hydroxyproline assay. Further, we achieved these results more efficiently than current methods in a rapid, high-throughput manner, with multiple types of collagenous tissue while maintaining accuracy.

bioengineering

Quantitative reconstruction of time-varying 3D cell forces with traction force optical coherence microscopy

Cellular traction forces (CTFs) play an integral role in both physiological processes and disease, and are a topic of interest in mechanobiology. Traction force microscopy (TFM) is a family of methods used to quantify CTFs in a variety of settings. State-of-the-art 3D TFM methods typically rely on confocal fluorescence microscopy, which can impose limitations on acquisition speed, volumetric coverage, and temporal sampling or coverage. In this report, we present the first quantitative implementation of a new TFM technique: traction force optical coherence microscopy (TF-OCM). TF-OCM leverages the capabilities of optical coherence microscopy and computational adaptive optics (CAO) to enable the quantitative reconstruction of 3D CTFs in scattering media with minute-scale temporal resolution. We applied TF-OCM to quantify CTFs exerted by isolated NIH-3T3 fibroblasts embedded in Matrigel, with five-minute temporal sampling, using images which spanned a 500x500x500 m3 field-of-view. Due to the reliance of TF-OCM on computational imaging methods, we have provided extensive discussion of the underlying equations, assumptions, and failure modes of these methods. TF-OCM has the potential to advance studies of biomechanical behavior in scattering media, and may be especially well-suited to the study of cell collectives such as spheroids, a prevalent model in mechanobiology research.

bioengineering

Multifunction control and evaluation of a 3D printed hand prosthesis with the Myo armband by hand amputees

Upper limb amputations are highly impairing injuries that can substantially limit the quality of life of a person. The most advanced dexterous prosthetic hands have remarkable mechanical features. However, in most cases, the control systems are a simple extension of basic control protocols, making the use of the prosthesis not intuitive and sometimes complex. Furthermore, the cost of dexterous prosthetic hands is often prohibitive, especially for the pediatric population and developing countries. 3D printed hand prostheses can represent an opportunity for the future. Open 3D models are increasingly being released, even for dexterous prostheses that are capable of moving each finger individually and actively rotating the thumb. However, the usage and test of such devices by hand amputees (using electromyography and classification methods) is not well explored. The aim of this article is to investigate the usage of a cost-effective system composed of a 3D printed hand prosthesis and a low-cost myoelectric armband. Two subjects with transradial amputation were asked to wear a custom-made socket supporting the HANDi Hand and the Thalmic Labs Myo armband. Afterwards, the subjects were asked to control and use the prosthetic hand to grasp several objects by attempting to perform a set of different hand gestures. Both the HANDi Hand and the Myo armband performed well during the test, which is encouraging considering that the HANDi Hand was developed as a research platform. The results are promising and show the feasibility of the multifunction control of dexterous 3D printed hand prostheses based on low-cost setups. Factors as the level of the amputation, neuromuscular fatigue and mechanical limitations of the 3D printed hand prosthesis can influence the performance of the setup. Practical aspects such as usability and robustness will need to be addressed for successful application in daily life. A video of the tests can be found at the following link: https://youtu.be/iPSCAbd17Qw

bioengineering

Gastrocnemius fascicles are shorter and more pennate immediately following acute Achilles tendon rupture

The purpose of this study was to characterize the short-term effects of Achilles tendon ruptures on medial gastrocnemius. We hypothesized that the fascicles of the medial gastrocnemius muscle of the injured Achilles tendon would be shorter and more pennate immediately following the injury and would persist throughout 4 weeks post-injury. B-mode longitudinal ultrasound images of the medial gastrocnemius were acquired in 10 adults who suffered acute Achilles tendon ruptures and were treated non-operatively. Ultrasound images were acquired during the initial clinical visit following injury as well as two and four weeks following this initial clinical visit. Resting muscle structure was characterized by measuring fascicle length, pennation angle, muscle thickness, and muscle echo intensity in both the injured and contralateral (control) limbs. Fascicle length was 15% shorter (P < 0.001) and pennation angle was 21% greater (P < 0.001) in the injured muscle compared to the uninjured (control) muscle at the presentation of injury (week 0). These differences in fascicle length and pennation angle persisted throughout the 4 weeks after the injury (P < 0.008). Muscle thickness changes were not detected at any of the post-injury visits (difference < 4%, P > 0.04). Echo intensity of the injured limb was 8% lower at the presentation of the injury and 11% lower (P = 0.008) than the contralateral muscle at 2 weeks following injury (P < 0.001) but returned to within 1% by 4 weeks (P = 0.393). Our results suggest that Achilles tendon ruptures elicit rapid changes in the configuration and quality of the medial gastrocnemius, which may explain long-term functional deficits.

bioengineering

CopySwitch - in vivo optimization of gene copy numbers for heterologous gene expression in Bacillus subtilis

1.The Gram-positive bacterium Bacillus subtilis has long been used as a host for production and secretion of industrially relevant enzymes like amylases and proteases. It is imperative for optimal efficiency, to balance protein yield and correct folding. Gene copy numbers are an important tuning valve for the optimization of heterologous gene expression. While some genes are best expressed from many gene copies, for other genes, medium or even single copy numbers are the only way to avoid formation of inclusion bodies, toxic gene dosage effects or achieve desired levels for metabolic engineering. In order to provide a simple and robust method to address above-mentioned issues in the Gram-positive bacterium Bacillus subtilis, we have developed an automatable system for the tuning of heterologous gene expression based on the hosts intrinsic natural competence and homologous recombination capabilities. By supplying our reporter strains with a linearized, low copy number plasmid containing homology regions left and right of the reporter genes and an antibiotic resistance marker, we could show an up to 3.6-fold higher gfp (green fluorescent protein) expression and up to 1.3-fold higher mPLC (mature phospholipase C) expression after successful recombination and thus circularization of our plasmid. Furthermore, the plasmid-borne gfp expression seems to be more stable, since over the whole cultivation period the share of fluorescent cells compared to all measured cells is consistently higher.

bioengineering

A new universal pore measurement and clustering approach for surgical meshes

The pore structure and pore size is a crucial characteristic of surgical meshes. A huge amount of different approaches for mesh classification based on pore size or materials are available. It is difficult to use these classification methods because of the large variety in knitting structures and pore shapes. No agreement on an established method to measure the pore size is available despite the fact that the surgical community agrees that pore size and geometry are crucial factors for the result of a hernia repair. In this publication a new approach to characterize meshes based on their pore shape and pore size is presented. The pore size is defined by the largest inscribed circle within a mesh pore and the smallest circumscribed circle outside the pore, in addition to hence calculated values. This allows a characterization with regards to tissue ingrowth and bridging behavior. The measurements are made using the scientific image processing software ImageJ and additional customized software plug-in. Since the program ImageJ is public domain and the plug-ins are available, the measurements can be reproduced. Furthermore, the presented pore descriptions can also be used for manual pore size verification.

bioengineering

A new causality measure

Let there are n i.i.d observations, each producing a two tuple of real values (xi, yi), i [isin] {1,......, n} giving rise to random variables X = (x1,..., xn) and Y = (y1,..., yn). What is the statistical significance of the hypothesis that an increase in the independent variable X is causing an increase (or decrease) to the dependent variable Y ?

bioengineering

On Parameter Interpretability of Phenomenological-Based Semiphysical Models

Empirical and phenomenological based models are used to represent biological and physiological processes. Phenomenological models are derived from the knowledge of the mechanisms that underlie the behaviour of the system under study, while empirical models are derived from analysis of data to quantify relationships between variables of interest. For studying biological systems, the phenomenological modeling approach offers the great advantage of having a structure with variables and parameters with physical meaning that enhance the interpretability of the model and its further used for decision making. The interpretability property of models, however, remains a vague concept. In this study, we tackled the interpretability property for parameters of phenomenological-based models. To our knowledge, this property has not been deeply discussed, perhaps by the implicit assumption that interpretability is inherent to the phenomenological-based models. We propose a conceptual framework to address the parameter interpretability and its implications for parameter identifiability. We use as battle horse a simple but relevant model representing the enzymatic degradation of {beta}-casein by a Lactococcus lactis bacterium.

bioengineering

Optical Sectioning of Live Mammal with Near-Infrared Light Sheet

Deep-tissue three-dimensional optical imaging of live mammals in vivo with high spatiotemporal resolution in non-invasive manners has been challenging due to light scattering. Here, we developed near-infrared (NIR) light sheet microscopy (LSM) with optical excitation and emission wavelengths up to ~ 1320 nm and ~ 1700 nm respectively, far into the NIR-II (1000-1700 nm) region for 3D optical sectioning through live tissues. Suppressed scattering of both excitation and emission photons allowed one-photon optical sectioning at ~ 2 mm depth in highly scattering brain tissues. NIR-II LSM enabled non-invasive in vivo imaging of live mice, revealing never-before-seen dynamic processes such as highly abnormal tumor microcirculation, and 3D molecular imaging of an important immune checkpoint protein, programmed-death ligand 1 (PD-L1) receptors at the single cell scale in tumors. In vivo two-color near-infrared light sheet sectioning enabled simultaneous volumetric imaging of tumor vasculatures and PD-L1 proteins in live mammals.

bioengineering

scFTD-seq: freeze-thaw lysis based, portable approach toward high-quality distributed single-cell 3 mRNA profiling

Cellular barcoding of 3 mRNAs enabled massively parallel profiling of single-cell gene expression and has been implemented in droplet and microwell based platforms. The latter further adds the value for compatibility with low input samples, optical imaging, scalability, and portability. However, cell lysis in microwells remains suboptimal despite the recently developed sophisticated solutions. Here, we present scFTD-seq, a microchip platform for performing single-cell freeze-thaw lysis directly toward 3 mRNA sequencing. It offers format flexibility with a simplified, widely adoptable workflow that reduces the number of preparation steps and hands-on time, with the quality of data and the cost per sample matching that of the state-of-the-art scRNA-seq platforms. Freeze-thaw, known as an unfavorable lysis method resulting in possible RNA fragmentation, turns out to be fully compatible with single-cell 3 mRNA sequencing, which detects only ~50 bases at the 3 end. We applied it to the profiling of mixed populations including whole tumors for distinguishing all major cell types and to the profiling of circulating follicular helper T cells implicated in systemic lupus erythematosus pathogenesis. Our results delineate the heterogeneity in the transcriptional programs and effector functions of these rare pathogenic T cells. As scFTD-seq decouples on-chip cell isolation and the following library preparation steps, we envision it to potentially allow the sampling (capture of cells/beads in microwells) at the distributed sites including small clinics or point-of-care settings and downstream processing at a centralized facility, which should enable wide-spread adoption beyond academic laboratories - for any users even with no experience in scRNA-seq library generation.

bioengineering

IsoSense: frequency enhanced sensorless adaptive optics through structured illumination

We present IsoSense, a wavefront sensing method that mitigates sample dependency in image based sensorless adaptive optics applications in microscopy. Our method employs structured illumination to create additional, high spatial frequencies in the image through custom illumination patterns. This improves the reliability of image quality metric calculations and enables sensorless wavefront measurement even in samples with sparse spatial frequency content. We demonstrate the feasibility of IsoSense for aberration correction in a deformable mirror based structured illumination superresolution fluorescence microscope.

bioengineering