bioRxiv Science⌕ Search

bioRxiv · 10.1101/407254

Quantitative Mapping of Free-Standing Lipid Membranes on Nano-Porous Mica Substrates

Abstract

The physic-chemistry of biological membranes is at the origin of fundamental cellular functions such as vesicle trafficking, cell adhesion and migration1-3. Because most of intracellular shapes and local demixing of membranes take place in the nanometer scale, AFM becomes an extremely powerful technique to assess the properties of these biological membranes. Porous substrates provide an elegant strategy to avoid the conundrum of placing soft and thin biomembranes on hard substrates for AFM studies, although the surface chemistry make the actual substrates rather challenging setups. Here, we have engineered porous systems on the most widely used substrate in AFM, mica muscovite, with tunable pore sizes from some tens to few hundreds nanometers for biological applications. We show that free-standing bilayers on nano-porous can be obtained by using well-established vesicle spreading methods and that they display equivalent nano-mechanical stability and phsyco-chemical properties to that of membranes on conventional mica supports. By reducing the pore radius < 40 nm and limiting the contribution of membrane tension to the elastic response of free-standing membranes we estimate a bending modulus of 18 kbT and 73 kbT for DOPC and DPPC bilayers, respectively. The quantitative mapping of suspended membranes shows a different mechanical response at the pore rims, which is more pronounced for DPPC and suggest a different lipid ordering. We find that the combination of membrane bending and the different lipid packing at the edges of pores shapes the curvature of free-standing membranes on pores in the range of few tens of nm.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Costa, L., Carretero-Genevrier, A., Ferrain, E., Milhiet, P.-E., Picas, L.. 2018-09-03. Quantitative Mapping of Free-Standing Lipid Membranes on Nano-Porous Mica Substrates. https://doi.org/10.1101/407254

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Kinetic gating by an iron sulfur chain modulates flavin radical-pair spin chemistry in mitochondrial Complex I

Mitochondrial Complex I generates reactive oxygen species at its flavin cofactor, where spin dependent reaction pathways have been proposed. Models of this chemistry treat the flavin oxygen radical pair in isolation, although the flavin is wired to a chain of eight iron sulfur clusters. Here we model the pair with this chain using the human Complex I structure and open quantum system models of spin coupling and electron transfer. In the simulated network, spin coherence decays rapidly along the chain, whereas proximal clusters alter the calculated radical-pair singlet yield. Their influence is kinetically gated: a downstream cluster affects the modelled yield when its electron-transfer rate competes with radical pair recombination, a threshold robust to driving force and to the transfer model. Modelling does set the sign: one directional spin hops predict suppression and inflate coherence transport, whereas charge resolved transfer drives the singlet yield towards its spin-randomized limit unless triplet recombination dominates. Detectable spin dependent effects in this framework require superoxide spin relaxation to be substantially slower than in free solution, a condition not yet established for Complex I.

biophysics↗

Semidilute Polymer Scaling Controls PEG-induced Protein Phase Separation

When does polyethylene glycol (PEG) mass concentration provide a common measure of crowding strength across polymer chain lengths? Here we use bovine serum albumin (BSA) and PEG as a controlled depletion system and measure both coexisting phases to determine binodals, tie lines, and critical points across PEG molecular weights of 4--100 kDa. Phase diagrams for PEG 20, 35, and 100 kDa approximately collapse in mass-concentration coordinates, consistent with semidilute polymer scaling. Generalized free volume theory (GFVT) describes the BSA binodals and tie lines. It also approximately describes binodals for three additional globular proteins in PEG 35K, extending the comparison across proteins spanning 7.2--66.4 kDa. For the binary PEG mixtures tested, GFVT approximates the binodals using an effective polymer size corresponding to the weight-average molecular weight. These results identify a regime in which PEG mass concentration (g/L) provides a transferable measure of depletion-induced crowding.

biophysics↗

Correlation-resolved sum-frequency generation microscopy of biological tissue with bright twin beams

Sum-frequency generation (SFG) driven by bright twin beams generated through high-gain parametric down-conversion comprises a coherent component arising from correlated mode pairs and an incoherent component arising from interactions between uncorrelated modes. Modal correlations can enhance coherent SFG in anisotropic nonlinear media, for example by extending the effective interaction length. Whether such correlations can likewise benefit image formation in heterogeneous biological tissue remains unknown. Here we address this question by performing SFG imaging of biological tissue using bright twin beams as the excitation source. Spectral decomposition of the SFG signal separates its coherent and incoherent components, allowing us to reconstruct co-registered images and examine how twin-beam correlations influence image formation. In mouse skeletal muscle, the coherent-component image revealed sarcomere periodicity with a Bragg-spot-to-background ratio of approximately 310, compared with 7.5 in the incoherent-component image. In fresh human dermis, the coherent-component image showed greater Fourier power than the incoherent-component image in the 0.30-0.50 \mu m^{-1} band and a greater fractional autocovariance decay at short spatial lags. These results demonstrate that twin-beam correlations can enhance contrast and detectability at selected spatial frequencies in heterogeneous tissue. Correlation-resolved SFG microscopy thus offers a route for exploiting bright quantum-light sources in nonlinear optical bioimaging.

biophysics↗