bioRxiv Science⌕ Search

bioRxiv · 10.1101/2024.12.24.630234

Understanding the structure and mechanics of the sheep calcaneal enthesis: a relevant animal model for tissue engineering applications

Abstract

Tendon/enthesis injuries are a worldwide clinical problem. Along the enthesis, collagen fibrils show a progressive loss of anisotropy and an increase in mineralization reaching the bone. This causes gradients of mechanical properties. The design of scaffolds to regenerate these load-bearing tissues requires of being validated in vivo in relevant large animal models. The sheep tendon of triceps surae muscle is an optimal animal model for this scope with limited knowledge about its structure and mechanics. We decided to understand in-depth its structure and full-field mechanics. Collagen fibrils morphology was investigated via scanning electron microscopy revealing a marked change in orientation/dimensions passing from tendon to enthesis. Backscatter electron images and nanoindentation at the enthesis/bone marked small gradients of mineralization at the mineralized fibrocartilage reaching 27%wt and indentation modulus around 17-30 GPa. The trabecular bone instead had indentation modulus around 15-22 GPa. Mechanical tensile tests with digital image correlation confirmed the typical non-linear behavior of tendons (failure strain = 8.2{+/-}1.0%; failure force = 1369{+/-}187 N) with maximum principal strains reaching mean values of {varepsilon}p1[~]7%. The typical auxetic behavior of tendon was highlighted by the minimum principal strains ({varepsilon}p2[~]5%), progressively dampened at the enthesis. Histology revealed that this behavior was caused by a local thickening of the epitenon. Cyclic tests showed a force loss of 21{+/-}7 % at the last cycle. These findings will be fundamental for biofabrication and clinicians interested in designing the new generation of scaffolds for enthesis regeneration. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=120 SRC="FIGDIR/small/630234v1_ufig1.gif" ALT="Figure 1"> View larger version (48K): org.highwire.dtl.DTLVardef@143f0a8org.highwire.dtl.DTLVardef@16cb394org.highwire.dtl.DTLVardef@181be61org.highwire.dtl.DTLVardef@f9f2d9_HPS_FORMAT_FIGEXP M_FIG C_FIG Statement of SignificanceTendon and enthesis lesions are a clinical problem. To validate scaffolds for these applications large animal models are needed. Sheep tendon of triceps surae muscle is an optimal site for this scope. However, little is known about its extracellular matrix structure and mechanical properties. This work investigates the structure and mechanics of this tissue from different points of view. Scanning electron microscopy and histology studied its extracellular matrix morphology and composition. Backscattered electron images and nanoindentation assessed gradients of mineralization and stiffness at the enthesis. Mechanical tensile and cyclic tests coupled with digital image correlation elucidated its mechanics and superficial strain distribution. These findings will be fundamental for biofabrication and clinician experts to design innovative scaffolds to regenerate the enthesis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sensini, A., Raimondi, L., Malerba, A., Peniche Silva, C. J., Zucchelli, A., Tits, A., Ruffoni, D., Blouin, S., Hartmann, M. A., van Griensven, M., Moroni, L.. 2024-12-25. Understanding the structure and mechanics of the sheep calcaneal enthesis: a relevant animal model for tissue engineering applications. https://doi.org/10.1101/2024.12.24.630234

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Surfactant-Assisted Colorimetric Signal Enhancement in Paper-Based Glucose Sensing

Paper-based colorimetric sensors offer a low-cost and accessible platform for point-of-care (POC) analysis, but enzyme activity loss during coating and drying can weaken analytical signals and require high enzyme loadings or complex immobilization procedures. Although surfactants are widely used to improve wettability in paper-based assays, their potential contribution to colorimetric performance beyond these effects remains unclear. Here, we investigated surfactant-assisted colorimetric signal enhancement in a glucose assay implemented on a 96-puddle paper plate (96-PPP) and identified Tween 20 as the most effective surfactant. Its effect on detection performance became more pronounced as glucose oxidase (GOx) loading decreased; at 0.1 mg/mL GOx, Tween 20 lowered the limit of detection (LoD) from 0.113 to 0.034 mg/mL (approximately 3.3-fold) over a working range of 0-5 mg/mL, despite no statistically significant change in the measured contact angle at this loading. Tween 20 had no appreciable effect on the reaction in solution but preserved 95% of the apparent reaction rate constant after drying, compared with 11% without it, and atomic force microscopy (AFM) revealed a more dispersed dried enzyme morphology on mica. Tween 20-containing sensors also showed slower signal decay during repeated wetting-drying cycles and thermal stress, retained 77% (vs 26%) of the response at 400 mM NaCl, and exhibited within-PPP and between-batch coefficients of variation (CVs) below 10% (vs 12.3-19.5%), while maintaining glucose selectivity over potentially interfering molecules. These results indicate that Tween 20 enhances paper-based glucose sensing beyond wettability, in part by retaining enzyme cascade activity during drying, although the contributions of the individual enzymes and the underlying mechanism remain to be established.

bioengineering↗

Engineering CAR-T cells to remodel the mucin-rich cancer cell glycocalyx

The dense glycocalyx of cancer cells can restrict immune-cell access to surface antigens and limit CAR-T cell activity. Here, we show that mucin density and epitope position determine how glycocalyx remodeling affects CAR-T cell recognition and killing. We identify KLK5 as a human protease that cleaves tumor-associated mucins, increases access to membrane-proximal antigens, and enhances CAR-T cell function. We then engineer CAR-T cells to display or secrete KLK5, enabling remodeling of the tumor glycocalyx during antigen recognition. KLK5-engineered CAR-T cells improved tumor control across multiple xenograft models, and KLK5-secreting MUC17 CAR-T cells produced the strongest in vivo benefit, prolonging survival compared with conventional MUC17 CAR-T cells. These findings show that CAR-T cells can be engineered to breach the mucin-rich glycocalyx while preserving accessible target epitopes.

bioengineering↗

Wall stiffening is a primary contributor to motility loss in Crohn's disease: an electromechanical modeling study

Fibrotic strictures are among the most disabling complications of Crohn's disease, permanently narrowing the bowel and impairing motility, yet no approved therapy reverses them. Chronic inflammation alters pacemaker-network coupling, smooth-muscle excitability, and calcium-dependent contractility, while fibrosis thickens the bowel wall, narrows the lumen, and changes tissue mechanics. The relative contributions of these coupled electrical, contractile, and structural alterations to motility loss remain unclear. To address this gap, we develop an integrated electromechanical finite-element framework for fibrostenosing Crohn's disease that couples a fibrosis-driven growth model with a FitzHugh-Nagumo electromechanical model. A full-factorial 25 design of experiments is used to quantify the relative effects of electrical diffusivity, excitation threshold, peak active stress, wall stiffness, and hypertrophic remodeling on cyclic lumen-volume deformation. Motility is quantified by the standard deviation of lumen volume over one contraction cycle. Within the parameter ranges examined, increased wall stiffness emerged as the dominant contributor to motility loss, followed by impaired smooth-muscle contractility. Changes in excitation threshold, hypertrophic remodeling, and electrical diffusivity produced substantially smaller effects. Pairwise interactions were small relative to the dominant main effects, indicating that the mechanisms contributed largely through their individual effects. Our findings suggest that limiting wall stiffening while preserving smooth-muscle contractile function may provide a therapeutic strategy for maintaining intestinal motility in fibrostenosing Crohn's disease.

bioengineering↗