bioRxiv Science⌕ Search

Biology subjects

Blouin, S.

Publications and source records attributed to Blouin, S..

7 recordsLinked to original sources

Mitochondrial dysfunction plays a key role in premature musculoskeletal aging in hypochondroplasia mouse model

Hypochondroplasia (HCH) is a mild form of chondrodysplasia, caused by variants in fibroblast growth factor receptor 3 (FGFR3). Today, the biological mechanism underlying musculoskeletal aging in HCH remains largely unknown. In this study, we show that Hch mice exhibit phenotypic traits of bone fragility and accelerated age-dependent articular cartilage and subchondral bone changes. Hch mice also presented decreased muscle strength and reduction in muscle fibers size. Furthermore, proteomics analyses of the cortical bone revealed that Hch mice follow a different aging trajectory than control. FGFR3 mutation leads to a premature boost of the mitochondrial processes forcing the mutant to reach a physiological state much earlier than the control. Together, these findings demonstrate that aging in Hch mice is accompanied by bone fragility and osteoarthritis-like changes. Proteomics analyses highlighted the key role for mitochondria in the cortical bone of Hch mice, providing insight into the mechanisms underlying premature aging in HCH.

genetics↗

Crop yields under simulated nuclear winter: a growth chamber experiment

A global nuclear war could inject soot into the stratosphere, blocking sunlight and causing rapid cooling. Assessments of the resulting agricultural collapse rely on crop models never validated under such conditions. We grew wheat, canola, and potato in growth chambers simulating the light and temperature of an extreme nuclear winter at tropical and temperate sites. In the tropical chamber (18-20 {degrees}C, 200 mol m-2 s-1 PAR), all three crops produced viable yields. Wheat yielded 2.1-2.3 t/ha (n=3 well-watered, n=3 water-stressed pots), 60% of the global average, and single-pot observations of canola and potato suggested biological yields comparable to global averages. In the temperate chamber simulating nuclear winter irradiance (60-360 mol m-2 s-1), wheat stems collapsed under their own weight. Although hand-harvesting recovered 0.6-2.8 t/ha of grain, mechanical field harvest of a flat canopy would recover substantially less. This failure mode was not observed in a higher-light control chamber and is not captured by existing crop models, which may therefore overestimate temperate cereal production under nuclear winter. Canola produced comparable yields under both temperate light regimes without lodging. Empirical screening of additional staples is needed to identify which remain viable under nuclear winter.

plant biology↗

Aging modifies microstructure and material properties of mineralized cartilage and subchondral bone in the murine knee

The osteochondral junction is a specialized region ensuring the biomechanical and biological integration of the unmineralized articular cartilage with the subchondral bone through an intermediate layer of mineralized cartilage. This location is of clinical relevance, being the target of osteoarthritis. While aging is considered a risk factor for osteoarthritis, the interplay between microstructural and material changes during aging and predisposing to joint degeneration is not fully clear. This is especially true for mineralized cartilage, which remains understudied despite its critical role in load transfer from unmineralized articular cartilage to bone. We investigate age-related alterations of mineralized cartilage and subchondral bone in rat tibiae of adult and aged animals using a multimodal, high-resolution, correlative analysis. Our approach includes micro-computed tomography to measure microstructural features, second harmonic generation imaging to visualize collagen organization, quantitative backscattered electron imaging to map local mineral content, and nanoindentation to obtain mechanical properties. Mineralized cartilage and subchondral bone exhibited distinct age-related modifications. At the architectural level, the subchondral plate thickened and the trabecular network became coarser, those changes being different from those observed in the metaphysis. At the tissue level, mineralized cartilage was less mineralized than bone but exhibits a greater relative increase of mineral content with age, underlying differences in mineralization. A central observation is that aging led to an abrupt transition in mineral content and mechanical properties across the interface between unmineralized and mineralized cartilage, with a conceivable impact on stress localization. Overall, these changes may alter load transfer and contribute to age-related joint degeneration.

bioengineering↗

Cement lines are stiffer and harder than bone but exhibit different mineral-mechanics relationships due to thicker and shorter mineral particles

The remarkable mechanical performance of bone arises from its complex hierarchical structure and from the presence of numerous internal interfaces joining the different components. Formed during bone remodeling, the cement line (CL) is a thin interface surrounding osteons. Although often neglected due to its small size, the CL has been suggested to play an important role in bone fracture toughness. However, there is an ongoing debate about its specific structure and mechanical behavior. Here, we investigate the composition-mechanics relationship at the CL and surrounding bone in human osteons using multiple methods in a correlative manner. We found that the CL is stiffer and harder than adjacent osteonal tissue. However, the CL requires more mineral than bone to attain the same stiffness and hardness. Analyzing the nanoscale properties of the mineral, we found thicker but shorter particles at the CL. Using a mechanical model, we interpreted the lower aspect ratio of the mineral particles as a less effective way to reinforce the collagen matrix. Casting our findings into a computational model, we questioned the possible protective role of the CL, which is not a soft interface as traditionally believed.

bioengineering↗

Understanding the structure and mechanics of the sheep calcaneal enthesis: a relevant animal model for tissue engineering applications

Tendon/enthesis injuries are a worldwide clinical problem. Along the enthesis, collagen fibrils show a progressive loss of anisotropy and an increase in mineralization reaching the bone. This causes gradients of mechanical properties. The design of scaffolds to regenerate these load-bearing tissues requires of being validated in vivo in relevant large animal models. The sheep tendon of triceps surae muscle is an optimal animal model for this scope with limited knowledge about its structure and mechanics. We decided to understand in-depth its structure and full-field mechanics. Collagen fibrils morphology was investigated via scanning electron microscopy revealing a marked change in orientation/dimensions passing from tendon to enthesis. Backscatter electron images and nanoindentation at the enthesis/bone marked small gradients of mineralization at the mineralized fibrocartilage reaching 27%wt and indentation modulus around 17-30 GPa. The trabecular bone instead had indentation modulus around 15-22 GPa. Mechanical tensile tests with digital image correlation confirmed the typical non-linear behavior of tendons (failure strain = 8.2{+/-}1.0%; failure force = 1369{+/-}187 N) with maximum principal strains reaching mean values of {varepsilon}p1[~]7%. The typical auxetic behavior of tendon was highlighted by the minimum principal strains ({varepsilon}p2[~]5%), progressively dampened at the enthesis. Histology revealed that this behavior was caused by a local thickening of the epitenon. Cyclic tests showed a force loss of 21{+/-}7 % at the last cycle. These findings will be fundamental for biofabrication and clinicians interested in designing the new generation of scaffolds for enthesis regeneration. Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=120 SRC="FIGDIR/small/630234v1_ufig1.gif" ALT="Figure 1"> View larger version (48K): org.highwire.dtl.DTLVardef@143f0a8org.highwire.dtl.DTLVardef@16cb394org.highwire.dtl.DTLVardef@181be61org.highwire.dtl.DTLVardef@f9f2d9_HPS_FORMAT_FIGEXP M_FIG C_FIG Statement of SignificanceTendon and enthesis lesions are a clinical problem. To validate scaffolds for these applications large animal models are needed. Sheep tendon of triceps surae muscle is an optimal site for this scope. However, little is known about its extracellular matrix structure and mechanical properties. This work investigates the structure and mechanics of this tissue from different points of view. Scanning electron microscopy and histology studied its extracellular matrix morphology and composition. Backscattered electron images and nanoindentation assessed gradients of mineralization and stiffness at the enthesis. Mechanical tensile and cyclic tests coupled with digital image correlation elucidated its mechanics and superficial strain distribution. These findings will be fundamental for biofabrication and clinician experts to design innovative scaffolds to regenerate the enthesis.

bioengineering↗

The mineralization of osteonal cement line depends on where the osteon is formed

The cement line (CL) is a thin layer separating secondary osteons from interstitial bone and other osteons. It is assumed to play a significant role in bone fracture resistance, owing to its ability to deflect or arrest microcracks. Despite the possible role for bone quality, the CL is still one of the least understood microstructural features of bones, with unknowns on CL composition, mineralization, and mechanical properties. This study, focusing on CL mineralization, aims to elucidate the interplay between the mineral content of the CL and of adjacent bone tissue. Using quantitative backscattered electron imaging, osteons with different degrees of mineralization coming from human femoral samples were analyzed. We implemented a spatially resolved analysis of the mineral content in layers along the CL, considering both regions inside the osteon (i.e., formed soon after CL deposition) and outside (i.e., already present at the time of CL deposition). We found that the mineral content of the CL correlates strongly with the mineral content outside of the osteon, but not inside. Assuming the mineral content of the osteon as a proxy of its age, we demonstrate that not only the osteon, but also the CL increases its mineral content with time. However, the rate of increase is lower in the CL. Importantly, the specific value of the high initial mineral content of the CL depends on the mineral content of the local surrounding, in which the osteon was formed. Our findings highlight the central role of the local degree of mineralization of the bone around the osteon for building the CL.

bioengineering↗

3D osteocyte lacunar morphometry of human bone biopsies with high resolution microCT: from monoclonal gammopathy to newly diagnosed multiple myeloma

Osteocytes are mechanosensitive, bone-embedded cells which are connected via dendrites in a lacuno-canalicular network and regulate bone resorption and formation balance. Alterations in osteocyte lacunar volume, shape and density have been identified in conditions of aging, osteoporosis and osteolytic bone metastasis, indicating patterns of impaired bone remodeling, osteolysis and disease progression. Osteolytic bone disease is a hallmark of the hematologic malignancy multiple myeloma (MM), in which monoclonal plasma cells in the bone marrow disrupt the bone homeostasis and induce excessive resorption at local and distant sites. Qualitative and quantitative changes in the 3D osteocyte lacunar morphometry have not yet been evaluated in MM, nor in the precursor conditions monoclonal gammopathy of undetermined significance (MGUS) and smoldering multiple myeloma (SMM). In this study, we characterized the osteocyte lacunar morphology in trabecular bone of the iliac crest at the ultrastructural level using high resolution microCT in human bone biopsy samples of three MGUS, two SMM and six newly diagnosed MM. In MGUS, SMM and MM we found a trend for lower lacunar density and a shift towards larger lacunae with disease progression (higher 50% cutoff of the lacunar volume cumulative distribution) in the small osteocyte lacunae 20-900 m3 range compared to control samples. In the larger lacunae 900-3000 m3 range, we detected significantly higher lacunar density and microporosity in the MM group compared to the MGUS/SMM group. Regarding the shape distribution, the MGUS/SMM group showed a trend for flatter, more elongated and anisotropic osteocyte lacunae compared to the control group. Altogether, our findings suggest that osteocytes in human MM bone disease undergo changes in their lacunae density, volume and shape, which could be an indicator for osteolysis and disease progression. Future studies are needed to understand whether alterations of the lacunae architecture affect the mechanoresponsiveness of osteocytes and ultimately bone adaptation and fracture resistance in MM and its precursors conditions.

bioengineering↗