bioRxiv Science⌕ Search

Biology subjects

Readioff, R.

Publications and source records attributed to Readioff, R..

3 recordsLinked to original sources

Image-based parametric finite element modelling for studying contact mechanics in human knee joints

PurposeThis study presents a framework for generating patient-specific finite element models, parameterised and optimised for contact mechanics from computed tomography (CT) scans, by avoiding the segmentation step usually employed to transform medical images into 3D models. Two morphological parameters affecting contact mechanics were investigated in the framework development: tibial cartilage thickness and tibial spine height. This study explores the effect of the interplay of these parameters in load sharing between meniscus and articulating cartilage, meniscal posterior and anterior roots strain and menisci kine-matics. MethodsMorphological measurements from four knee CT scans were collected, such as the maximum thickness of the tibial cartilage (ranging from 1.1 to 5.2 mm), the height of the tibial spine (ranging from 3.55 to 10.1 mm), and the width of the tibial plateau in both the coronal (ranging from 27.3 to 36.17 mm) and sagittal (ranging from 31.79 to 53.77 mm) planes. These measurements were taken for the lateral tibial plateau for both left and right knees. Subsequently, three finite element (FE) models were generated, comprising lateral tibial plateaus, lateral femoral condyle and lateral meniscus. The tibial cartilage thickness was kept at a constant value of 1 mm while varying the tibial spine height within the range measured from the CT images. This resulted in three FE models with varying spine heights, categorised as large (height = 7.42 mm), medium (height = 4.25 mm), and small (height = 1.63 mm) tibial spine heights. The menisci in the FE models were generated to be congruent with the tibial plateau. For the first time, this study advances the representations of the knee menisci microstructure in FE modelling, such that we have generated meniscus FE models with three layers of a hyperelastic model in which layer thickness and layer-specific hyperelastic material parameters are derived from our previous experimental work. ResultsThe load sharing between the meniscus and articular cartilage was not sensitive to the varying tibial spine heights. In all three FE models, cartilage carried more than 90% of the applied load. However, the meniscus kinematics and root strains varied considerably with changing tibial spine heights. The small tibial spine height model predicted the highest meniscus movements (8.12 and 9.33 mm in the radial and circumferential directions, respectively) and the highest root strain (21.92 and 22.19 mm/mm in the anterior and posterior roots, respectively). ConclusionOur framework can generate finite element models of patients knees using clinical data (i.e., CT scans) without the need for lengthy image segmentation. This process is not only time-efficient but also independent of imaging operators. The models converge quickly ({inverted question}30 minutes on 2 cores) using an implicit solver with non-linear geometry and have the capability to predict contact mechanics between the articulating surfaces, meniscus kinematics and root strains. The modelling strategy presented here can provide valuable insights into predicting changes in the mechanics of soft tissues in the knee joint. It is particularly useful for investigating injury and surgical mechanisms related to the meniscus.

bioengineering↗

Biomechanics of aging and osteoarthritic human knee ligaments

BackgroundLigaments work to stabilize the human knee joint and prevent excessive movement. Whilst ligaments are known to decline in structure and function with aging, there has been no systematic effort to study changes in gross mechanical properties in the four major human knee ligaments due to osteoarthritis (OA). This study aims to collate material properties for the anterior (ACL) and posterior (PCL) cruciate ligaments, medial (MCL) and lateral (LCL) collateral ligaments. Our cadaveric samples come from a diverse demographic from which the effects of aging and OA on bone and cartilage material properties have already been quantified. Therefore, by combining our previous bone and cartilage data with the new ligament data from this study we are facilitating subject-specific whole-joint modelling studies. MethodsThe demographics of the collected cadaveric knee joints were diverse with age range between 31 to 88 years old, and OA International Cartilage Repair Society grade 0 to 4. Twelve cadaveric human knee joints were dissected, and bone-ligament-bone specimens were extracted for mechanical loading to failure. Ligament material properties were determined from the load-extension curves, namely: linear and ultimate (failure) stress and strain, secant modulus, tangent modulus, and stiffness. ResultsThere were significant negative correlations between age and ACL linear force (p=0.01), stress (p=0.03) and extension (p=0.05), ACL failure force (p=0.02), stress (p=0.02) and extension (p=0.02), PCL secant (p=0.02) and tangent (p=0.02) modulus, and LCL stiffness (p=0.05). Significant negative correlations were also found between OA grades and ACL linear force (p=0.05), stress (p=0.02), extension (p=0.01) and strain (p=0.03), and LCL failure stress (p=0.05). However, changes in age or OA grade did not show a statistically significant correlation with the MCL tensile parameters. Trends showed that almost all the tensile parameters of the ACL and PCLs decreased with increasing age and progression of OA. Due to small sample size, the combined effect of age and presence of OA could not be statistically derived. ConclusionsThis research is the first to correlate changes in tensile properties of the four major human knee ligaments to aging and OA. The current ligament study when combined with our previous findings on bone and cartilage for the same twelve knee cadavers, supports conceptualization of OA as a whole-joint disease that impairs the integrity of many peri-articular tissues within the knee. The subject-specific data pool consisting of the material properties of the four major knee ligaments, subchondral and trabecular bones and articular cartilage will aid reconstruction and graft replacements and advance knee joint finite element models, whilst knowledge of aged or diseased mechanics may direct future therapeutic interventions.

bioengineering↗

Viscoelastic characteristics of the canine cranial cruciate ligament complex at slow strain rates

Ligaments including the cruciate ligaments support and transfer loads between bones applied to the knee joint organ. The functions of these ligaments can get compromised due to changes to their viscoelastic material properties. Currently there are discrepancies in the literature on the viscoelastic characteristics of knee ligaments which are thought to be due to tissue variability and different testing protocols. The aim of this study was to characterise the viscoelastic properties of healthy cranial cruciate ligaments (CCLs), from the canine knee (stifle) joint, with a focus on the toe region of the stress-strain properties where any alterations in the extracellular matrix which would affect viscoelastic properties would be seen. Six paired CCLs, from skeletally mature and disease-free Staffordshire bull terrier stifle joints were retrieved as a femur-CCL-tibia complex and mechanically tested under uniaxial cyclic loading up to 10 N at three strain rates, namely 0.1, 1 and 10 %/min, to assess the viscoelastic property of strain rate dependency. The effect of strain history was also investigated by subjecting contralateral CCLs to an ascending (0.1, 1 and 10 %/min) or descending (10, 1 and 0.1 %/min) strain rate protocol. The differences between strain rates were not statistically significant. However, hysteresis and recovery of ligament lengths showed some dependency on strain rate. Only hysteresis was affected by the test protocol and lower strain rates resulted in higher hysteresis and lower recovery. These findings could be explained by the slow process of uncrimping of collagen fibres and the contribution of proteoglycans in the ligament extracellular matrix to intra-fibrillar gliding, which results in more tissue elongations and higher energy dissipation. This study further expands our understanding of canine CCL behaviour, providing data for material models of femur-CCL-tibia complexes, and demonstrating the challenges for engineering complex biomaterials such as knee joint ligaments.

bioengineering↗