bioRxiv Science⌕ Search

bioRxiv · 10.1101/2023.09.07.556747

Image-based parametric finite element modelling for studying contact mechanics in human knee joints

Abstract

PurposeThis study presents a framework for generating patient-specific finite element models, parameterised and optimised for contact mechanics from computed tomography (CT) scans, by avoiding the segmentation step usually employed to transform medical images into 3D models. Two morphological parameters affecting contact mechanics were investigated in the framework development: tibial cartilage thickness and tibial spine height. This study explores the effect of the interplay of these parameters in load sharing between meniscus and articulating cartilage, meniscal posterior and anterior roots strain and menisci kine-matics. MethodsMorphological measurements from four knee CT scans were collected, such as the maximum thickness of the tibial cartilage (ranging from 1.1 to 5.2 mm), the height of the tibial spine (ranging from 3.55 to 10.1 mm), and the width of the tibial plateau in both the coronal (ranging from 27.3 to 36.17 mm) and sagittal (ranging from 31.79 to 53.77 mm) planes. These measurements were taken for the lateral tibial plateau for both left and right knees. Subsequently, three finite element (FE) models were generated, comprising lateral tibial plateaus, lateral femoral condyle and lateral meniscus. The tibial cartilage thickness was kept at a constant value of 1 mm while varying the tibial spine height within the range measured from the CT images. This resulted in three FE models with varying spine heights, categorised as large (height = 7.42 mm), medium (height = 4.25 mm), and small (height = 1.63 mm) tibial spine heights. The menisci in the FE models were generated to be congruent with the tibial plateau. For the first time, this study advances the representations of the knee menisci microstructure in FE modelling, such that we have generated meniscus FE models with three layers of a hyperelastic model in which layer thickness and layer-specific hyperelastic material parameters are derived from our previous experimental work. ResultsThe load sharing between the meniscus and articular cartilage was not sensitive to the varying tibial spine heights. In all three FE models, cartilage carried more than 90% of the applied load. However, the meniscus kinematics and root strains varied considerably with changing tibial spine heights. The small tibial spine height model predicted the highest meniscus movements (8.12 and 9.33 mm in the radial and circumferential directions, respectively) and the highest root strain (21.92 and 22.19 mm/mm in the anterior and posterior roots, respectively). ConclusionOur framework can generate finite element models of patients knees using clinical data (i.e., CT scans) without the need for lengthy image segmentation. This process is not only time-efficient but also independent of imaging operators. The models converge quickly ({inverted question}30 minutes on 2 cores) using an implicit solver with non-linear geometry and have the capability to predict contact mechanics between the articulating surfaces, meniscus kinematics and root strains. The modelling strategy presented here can provide valuable insights into predicting changes in the mechanics of soft tissues in the knee joint. It is particularly useful for investigating injury and surgical mechanisms related to the meniscus.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Readioff, R., Seil, R., Mouton, C., Marks, L., Barrera, O.. 2023-09-10. Image-based parametric finite element modelling for studying contact mechanics in human knee joints. https://doi.org/10.1101/2023.09.07.556747

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗