bioRxiv Science⌕ Search

bioRxiv · 10.1101/2021.11.21.469435

Biomechanics of aging and osteoarthritic human knee ligaments

Abstract

BackgroundLigaments work to stabilize the human knee joint and prevent excessive movement. Whilst ligaments are known to decline in structure and function with aging, there has been no systematic effort to study changes in gross mechanical properties in the four major human knee ligaments due to osteoarthritis (OA). This study aims to collate material properties for the anterior (ACL) and posterior (PCL) cruciate ligaments, medial (MCL) and lateral (LCL) collateral ligaments. Our cadaveric samples come from a diverse demographic from which the effects of aging and OA on bone and cartilage material properties have already been quantified. Therefore, by combining our previous bone and cartilage data with the new ligament data from this study we are facilitating subject-specific whole-joint modelling studies. MethodsThe demographics of the collected cadaveric knee joints were diverse with age range between 31 to 88 years old, and OA International Cartilage Repair Society grade 0 to 4. Twelve cadaveric human knee joints were dissected, and bone-ligament-bone specimens were extracted for mechanical loading to failure. Ligament material properties were determined from the load-extension curves, namely: linear and ultimate (failure) stress and strain, secant modulus, tangent modulus, and stiffness. ResultsThere were significant negative correlations between age and ACL linear force (p=0.01), stress (p=0.03) and extension (p=0.05), ACL failure force (p=0.02), stress (p=0.02) and extension (p=0.02), PCL secant (p=0.02) and tangent (p=0.02) modulus, and LCL stiffness (p=0.05). Significant negative correlations were also found between OA grades and ACL linear force (p=0.05), stress (p=0.02), extension (p=0.01) and strain (p=0.03), and LCL failure stress (p=0.05). However, changes in age or OA grade did not show a statistically significant correlation with the MCL tensile parameters. Trends showed that almost all the tensile parameters of the ACL and PCLs decreased with increasing age and progression of OA. Due to small sample size, the combined effect of age and presence of OA could not be statistically derived. ConclusionsThis research is the first to correlate changes in tensile properties of the four major human knee ligaments to aging and OA. The current ligament study when combined with our previous findings on bone and cartilage for the same twelve knee cadavers, supports conceptualization of OA as a whole-joint disease that impairs the integrity of many peri-articular tissues within the knee. The subject-specific data pool consisting of the material properties of the four major knee ligaments, subchondral and trabecular bones and articular cartilage will aid reconstruction and graft replacements and advance knee joint finite element models, whilst knowledge of aged or diseased mechanics may direct future therapeutic interventions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Peters, A. E., Geraghty, B., Bates, K. T., Akhtar, R., Readioff, R., Comerford, E.. 2021-11-21. Biomechanics of aging and osteoarthritic human knee ligaments. https://doi.org/10.1101/2021.11.21.469435

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering↗

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering↗

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering↗