bioRxiv Science⌕ Search

bioRxiv · 10.64898/2026.10.19.760310

Optogenetic and sonogenetic pacing of unmodified cardiac tissue upon quick integration with specialized biological actuators

Abstract

Electrical stimulation for cardiac pacing has been in clinical use for 100 years and it is the current standard. Alternative scalable pacing methods that are contactless, with good spatial precision and can also be cell-selective are of interest for both in vitro and in vivo applications. Cardiac pacing by light or by ultrasound (US) can be achieved using optogenetic transduction of the tissue and by enhancing responsiveness to ultrasound. In this work we create specialized biological actuators (cell spheroids) out of generic human cells, modified optogenetically (using Channelrhodopsin2) and sonogenetically (using human Piezo1), guide them to a desired location to promote quick integration with unmodified cardiac syncytia within less than two hours. We quantify their ability to confer pacing by light or US and to entrain the native cardiac tissue, modeled here with human induced pluripotent stem cell derived cardiomyocytes (hiPSC-CMs) grown in monolayers, quasi-3D oriented microtissues or cell spheroids. Magnetic guidance (via magnetic nanoparticles) speeds up integration and facilitates positioning to optimize electrotonic load for pacing; size match and three-dimensional growth also accelerate integration. Computational modeling corroborates the possibility to pace by light and by US. Using optogenetically-gated US pulses (0.5 MHz), we show entrainment in voltage and calcium responses and identify the best performing configurations. Experiments reveal the potential role of Piezo1, esp. when activated with Yoda1. The approach is shown to work with physiologically relevant heart cells, such as human cardiac fibroblasts as optimized actuators, and therefore can be considered for in vivo applications as part of heart regeneration efforts. High-throughput cardiotoxicity testing and drug screening in vitro can directly benefit from deployment of such biological actuators.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pettebone, M. E., Han, J. L., Forouzandehmehr, A., Chesla, O., Chua, C. J., Pozo, M. R., Heinson, Y. W., Liu, W., Entcheva, E.. 2026-10-20. Optogenetic and sonogenetic pacing of unmodified cardiac tissue upon quick integration with specialized biological actuators. https://doi.org/10.64898/2026.10.19.760310

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

A single-plane electrical impedance tomography framework for integrated liver and kidney assessment

Chronic liver and kidney diseases frequently coexist, but their assessment typically requires separate clinical workflows involving serum-based estimated glomerular filtration rate (eGFR) testing and liver elastography-based controlled attenuation parameter (CAP). Electrical impedance tomography (EIT) has recently shown promise for providing portable, non-invasive proxies for both reference measurements. However, existing multi-organ EIT assessment still requires different acquisition protocols for each organ. To simplify this procedure, we assessed the feasibility of a single-plane EIT framework for reconstructing organ-specific images and estimating liver and kidney health from one abdominal belt placement. Across diverse abdominal belt locations, opposite-plane deviation was significantly greater for eGFREIT estimates (2.92%; IQR, 0.46-12.53%) than for CAPEIT estimates (0.94%; IQR, 0.66-1.70%) (p < 0.01). For both organs, compared to images acquired at the conventional organ-specific planes, image correlation significantly decreased (both, p < 0.05) and normalized root mean squared error significantly increased (both, p < 0.05) at the furthest imaging plane, with these differences being numerically larger for the kidney. Together, these results supported the kidney plane as the preferred location for multi-organ assessment. Test-retest evaluation after belt removal and reapplication demonstrated that the correlation between two repeated CAPEIT estimates was just as strong at the kidney plane (R2 = 0.98, p < 0.001) as it was at the conventional liver plane (R2 = 0.97, p < 0.001). Finally, in an independent clinical cohort, kidney-plane CAPEIT estimates were significantly higher in participants with a high metabolic liver-risk profile (i.e. diabetes and high blood pressure) (p < 0.005). CAPEIT estimates also distinguished high and low metabolic risk groups with an AUC of 0.756. Together, these findings support the feasibility of a portable multi-organ EIT imaging framework capable of extracting complementary liver and kidney information from a single belt placement.

bioengineering↗

Live Spatial Transcriptomics Enables Longitudinal Tissue Mapping

Spatial transcriptomics has become an important technology in biomedical research by preserving the spatial context of gene expression in tissues and enabling the study of cellular states and interactions in situ. However, most existing methods provide only static snapshots of individual tissue specimens, requiring inference of the molecular dynamics underlying development, disease progression, and therapeutic response from different specimens rather than direct tracking in the same living tissue. Here, we introduce Live Spatial Transcriptomics (Live-ST), a technology that enables longitudinal, transcriptome-wide profiling of living tissue. Live-ST combines electroporation-based intracellular sampling and spatial barcoding to enable repeated, spatially resolved mRNA measurements in intact living tissue through next-generation sequencing. We demonstrate its capabilities by (i) benchmarking spatial mRNA capture in patterned two-dimensional cell systems, (ii) spatially profiling transcriptomes in intact, patient-derived living melanoma tissues while preserving tissue viability, and (iii) longitudinally tracking drug-response dynamics within the tumor microenvironment. Together, Live-ST enables repeated, non-destructive measurements of spatial gene expression, providing a new framework for studying dynamic tissue biology in native physiological and pathological contexts.

bioengineering↗

Mesoscale Soft Robotics for Mechanically Perturbing and Functionally Monitoring Responses in Human Organoids

Human organoids represent promising models for studies of significance to the biology and medical communities. Of the existing approaches for monitoring organoids, none offers the ability to apply programmable mechanical forces while simultaneously recording multi-modal physiological responses, of relevance to phenomena spanning from traumatic brain injuries to cardiac rhythm disorders. Here, we present a mesoscale soft robotic organoid interface that enables programmable delivery of forces to organoids of diverse shapes, and to map electrophysiological activity and mechanical responses. The platform combines actuation elements with integrated sensors for quantitative measurement and control. Studies using this technology reveal that spheroidal cortical organoids exhibit distinct responses to mechanical trauma, including silencing, recovery, and changes in neuronal firing patterns. Additional experiments on cardiac ring tissues demonstrate that sustained stretching induces beat-to-beat rhythm variability and altered conduction. The results establish a framework for investigating force-triggered transitions between physiological and disease-like states in human tissue models.

bioengineering↗