bioRxiv Science⌕ Search

bioRxiv · 10.64898/2026.09.26.754647

WHEN MICROSCALE TRANSPORT CONTROLS MACROSCALE TISSUE FREEZING: A PARAMETRIC REGIME ANALYSIS

Abstract

Devireddy et al. [1] previously showed that an enthalpy-based, macroscale model simulated tissue freezing histories are in close agreement with a coupled model incorporating cellular water transport and intracellular ice formation (IIF). That comparison, however, was performed for a limited set of tissue geometries, cooling conditions, and biophysical parameters. Here, we revisit that conclusion by reimplementing the published model from its governing equations and systematically expanding the parameter space to determine when microscale processes alter the predicted macroscale freezing response. We incorporate both surface catalyzed nucleation (SCN) and volume catalyzed nucleation (VCN) of intracellular ice with cellular osmotic dehydration and examine a broad range of tissue dimensions, cooling rates, convective boundary conditions, membrane permeabilities, cell sizes, activation energies, intracellular water fractions, and nucleation rates. Linearization of the cellular water transport equation about osmotic equilibrium yields an osmotic relaxation timethat can be compared with the local residence time of tissue undergoing phase change. Their ratio defines a dimensionless group, that organizes the transition between regimes in which the uncoupled enthalpy formulation and the coupled micro and macroscale formulation produce similar or substantially different results. Across the one-dimensional parameter space examined here, the two models remain within a prescribed thermal-error bound for the dimensionless group below approximately 0.1, whereas the discrepancy increases systematically above this threshold. Model divergence also depends on intracellular ice nucleation, i.e., when nucleation is sufficiently slow, cellular water transport can become rate limiting for latent heat release. Conversely, sufficiently rapid intracellular ice formation reduces the macroscopic discrepancy by providing an additional pathway for latent-heat release. Multidimensional simulations further show that geometry alone can move a nominally conventional freezing protocol into the coupled regime. In particular, multidirectional cooling can reduce the local residence time sufficiently to produce substantial differences in predicted frozen volume even when the corresponding thermal histories appear similar. Finally, we formulate an inverse approach for estimating IIF parameters from tissue scale thermal histories. Synthetic simulations indicate that parameter recovery is feasible within a finite range of cooling conditions, providing a testable strategy for future experimental measurements. Together, these results provide a mechanistic criterion for deciding when microscale biophysical processes must be retained in macroscale tissue-freezing models.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Devireddy, R.. 2026-09-30. WHEN MICROSCALE TRANSPORT CONTROLS MACROSCALE TISSUE FREEZING: A PARAMETRIC REGIME ANALYSIS. https://doi.org/10.64898/2026.09.26.754647

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

A harmonized phantom MRI quality control framework identifies sources of longitudinal and multi-site variability

The shift towards open science in preclinical research requires high-quality, comparable data adhering to FAIR principles, yet rigorous quality assurance (QA) and quality control (QC) frameworks remain less established in preclinical magnetic resonance imaging (MRI) than in clinical imaging. To address this limitation, a multicenter study was conducted across 21 international laboratories using standardized commercial liquid phantoms for mouse and rat MRI setups and a harmonized acquisition protocol. Data processing was centralized using AIDAqc, an automated pipeline extracting quantitative metrics including signal-to-noise ratio (SNR), temporal SNR (tSNR), ghost-to-signal ratio (GSR), and motion-equivalent temporal instability, combined with five complementary outlier-detection algorithms. The evaluated datasets encompassed magnetic field strengths from 3.0 to 16.4 T and heterogeneous coil and acquisition configurations. In mouse phantom data, SNR and tSNR were significantly lower at 3 T than at 7 and 9.4 T, whereas artifact-related metrics did not differ significantly between field-strength groups. In rat phantom data, differences between field strengths were less pronounced. At 7 T, substantial dataset-specific differences were observed in anatomical and functional quality metrics, also among datasets using the similar coil configuration. Multicenter reference values for frequently represented 7 T configurations were established, including SNR/tSNR of 48 {+/-} 3/48 {+/-} 1 dB for mouse surface-coil datasets and 49 {+/-} 3/44 {+/-} 4 dB for rat array-coil datasets. Longitudinal anatomical SNR showed generally low variability, whereas ghosting was more variable across time. Automated outlier detection additionally identified transient acquisition instabilities that were not always apparent by visual inspection. Together, these findings show that field strength and nominal coil configuration alone do not adequately characterize MRI performance and support standardized, longitudinal phantom-based QC combined with automated analysis as a practical approach for improving the reliability, transparency, and interoperability of multicenter preclinical MRI data.

bioengineering↗

Fiber alignment alone is insufficient to predict cellular contact guidance responses in engineered 3D collagen hydrogels

In breast cancer, collagen fiber alignment and the second harmonic generation forward-to-backward ratio (F/B), an optical measurement sensitive to fibril-scale organization within collagen fibers, have each been associated with metastatic outcome. Although both are measured at the tumor-stromal interface, in vitro studies have largely examined them separately, because experimental systems have not allowed the two to be varied independently. To address this technical gap, we used a microfluidic biofabrication approach to generate paired aligned and unaligned regions within 3D collagen hydrogels via extensional strain and varied measured F/B across gels by changing the pre-gel pH. The resulting library covered alignment values reported in breast tumors and F/B values associated with poorer metastatic outcome in invasive ductal carcinoma at matched matrix stiffness, pore diameter, and fiber fraction. In MDA-MB-231 cells, alignment biased migration along the fiber axis without changing migration speed, as expected, but the magnitude of the contact guidance response varied with measured F/B. In contrast, MCF-7 cells showed little overall contact guidance, yet migrated ~30% faster in high F/B than low F/B gels in both aligned and unaligned regions. Together, these results show that cells migrated differently in matrices with similar fiber alignment. Thus, including measured F/B may provide additional information to help anticipate how cells migrate in collagen environments that appear similar based on alignment alone.

bioengineering↗

Xolographic printing of cell-dense engineered living matter via iodixanol-driven enhancement of type II photoinitiation

Type II photoinitiators are essential for numerous applications, including advanced 3D printing techniques such as Xolography. Despite offering tunable wavelengths and reaction mechanisms, their limited photoreactivity hinders widespread adoption. Solutions to increase reactivity, particularly in aqueous solutions and in a biocompatible manner, are urgently needed. Here, we report the surprising finding that iodixanol enhances reactivity of type II photoinitiation systems. Supplementing Xolographic print resins with iodixanol increases photoreactivity, which reduces print times and light dosage tenfold, and enables printing of previously unprintable material formulations. Surprisingly, iodixanol supplementation also improves cell viability in a dose-dependent manner, while reducing cell-mediated light scattering. Together, this enables accurate Xolographic printing of highly cell-dense bioresins, which facilitated the biofabrication of engineered living matter with up to 100 M cells mL-1 (>40% cells by volume) with a resolution of ~65 microns. These advances enabled the first demonstration of tissue function in Xolographically-printed materials. Human induced pluripotent stem cell-derived cardiomyocytes were printed into contractile cardiac-like engineered living matter, which exhibited enhanced cell-cell contact and synchronous contractions, confirming tissue level function. As a highly water soluble, cytocompatible, and clinically approved compound, iodixanol therefore represents a valuable and translatable solution to improve the reactivity of type II photoinitiation systems, which enables volumetric biofabrication of highly cell dense living matter. This unlocks a new role for iodixanol in a wide variety of fields including dentistry, chemistry, organic photovoltaics, tissue engineering, and 3D printing.

bioengineering↗