HRV-GUI: A MATLAB Graphical User Interface for Heart Rate Variability Analysis and Validation Using Human, Rodent, and Clinical Diabetic Gastroparesis Data

Abstract

Background and Objective: Heart rate variability (HRV) analysis provides a non-invasive method for quantifying autonomic modulation from electrocardiographic recordings. However, practical HRV analysis often depends on fragmented workflows, limited signal-quality review, and software tools optimized for either human or preclinical recordings, but not both. This study developed and evaluated HRV-GUI, a MATLAB-based graphical interface for electrocardiogram (ECG)-derived HRV analysis in translational biomedical research. Methods: The HRV-GUI integrates electrocardiographic and RR interval loading, human and rat analysis modes, preprocessing, segment selection, automated R-peak detection, manual peak correction, RR interval generation, multi-domain HRV computation, diagnostic visualization, result export, and session saving/loading. The software was evaluated using deterministic synthetic RR interval datasets, baseline recordings from healthy human controls and healthy rats, and a clinical use-case comparison between healthy controls and patients with diabetic gastroparesis. Results: The HRV-GUI produced expected outputs in synthetic RR validation tests, including constant RR sequences, alternating RR sequences, outlier-containing RR sequences, and low-frequency- or high-frequency-dominant sinusoidal RR modulation. The software generated physiologically plausible HRV profiles in both human and rat recordings. In the clinical use-case analysis, patients with diabetic gastroparesis showed higher heart rate and sympathetic index, together with lower respiratory sinus arrhythmia, absolute low- and high-frequency spectral power, standard deviation of normal-to-normal intervals (SDNN), root mean square of successive differences (RMSSD), percentage of successive RR intervals differing by more than 50 ms (pNN50), Poincare short-term variability (SD1), and Poincare long-term variability (SD2) compared with healthy controls. Conclusions: HRV-GUI provides an integrated biomedical software workflow for ECG-derived HRV analysis. The validation results support its use for controlled RR testing, human and rodent ECG recordings, and clinical autonomic assessment in diabetic gastroparesis.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ali, M. K., Chen, J. D.. 2026-09-03. HRV-GUI: A MATLAB Graphical User Interface for Heart Rate Variability Analysis and Validation Using Human, Rodent, and Clinical Diabetic Gastroparesis Data. https://doi.org/10.64898/2026.09.01.748623

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related preprints

A single-plane electrical impedance tomography framework for integrated liver and kidney assessment

Chronic liver and kidney diseases frequently coexist, but their assessment typically requires separate clinical workflows involving serum-based estimated glomerular filtration rate (eGFR) testing and liver elastography-based controlled attenuation parameter (CAP). Electrical impedance tomography (EIT) has recently shown promise for providing portable, non-invasive proxies for both reference measurements. However, existing multi-organ EIT assessment still requires different acquisition protocols for each organ. To simplify this procedure, we assessed the feasibility of a single-plane EIT framework for reconstructing organ-specific images and estimating liver and kidney health from one abdominal belt placement. Across diverse abdominal belt locations, opposite-plane deviation was significantly greater for eGFREIT estimates (2.92%; IQR, 0.46-12.53%) than for CAPEIT estimates (0.94%; IQR, 0.66-1.70%) (p < 0.01). For both organs, compared to images acquired at the conventional organ-specific planes, image correlation significantly decreased (both, p < 0.05) and normalized root mean squared error significantly increased (both, p < 0.05) at the furthest imaging plane, with these differences being numerically larger for the kidney. Together, these results supported the kidney plane as the preferred location for multi-organ assessment. Test-retest evaluation after belt removal and reapplication demonstrated that the correlation between two repeated CAPEIT estimates was just as strong at the kidney plane (R2 = 0.98, p < 0.001) as it was at the conventional liver plane (R2 = 0.97, p < 0.001). Finally, in an independent clinical cohort, kidney-plane CAPEIT estimates were significantly higher in participants with a high metabolic liver-risk profile (i.e. diabetes and high blood pressure) (p < 0.005). CAPEIT estimates also distinguished high and low metabolic risk groups with an AUC of 0.756. Together, these findings support the feasibility of a portable multi-organ EIT imaging framework capable of extracting complementary liver and kidney information from a single belt placement.

bioengineering↗

Live Spatial Transcriptomics Enables Longitudinal Tissue Mapping

Spatial transcriptomics has become an important technology in biomedical research by preserving the spatial context of gene expression in tissues and enabling the study of cellular states and interactions in situ. However, most existing methods provide only static snapshots of individual tissue specimens, requiring inference of the molecular dynamics underlying development, disease progression, and therapeutic response from different specimens rather than direct tracking in the same living tissue. Here, we introduce Live Spatial Transcriptomics (Live-ST), a technology that enables longitudinal, transcriptome-wide profiling of living tissue. Live-ST combines electroporation-based intracellular sampling and spatial barcoding to enable repeated, spatially resolved mRNA measurements in intact living tissue through next-generation sequencing. We demonstrate its capabilities by (i) benchmarking spatial mRNA capture in patterned two-dimensional cell systems, (ii) spatially profiling transcriptomes in intact, patient-derived living melanoma tissues while preserving tissue viability, and (iii) longitudinally tracking drug-response dynamics within the tumor microenvironment. Together, Live-ST enables repeated, non-destructive measurements of spatial gene expression, providing a new framework for studying dynamic tissue biology in native physiological and pathological contexts.

bioengineering↗

Mesoscale Soft Robotics for Mechanically Perturbing and Functionally Monitoring Responses in Human Organoids

Human organoids represent promising models for studies of significance to the biology and medical communities. Of the existing approaches for monitoring organoids, none offers the ability to apply programmable mechanical forces while simultaneously recording multi-modal physiological responses, of relevance to phenomena spanning from traumatic brain injuries to cardiac rhythm disorders. Here, we present a mesoscale soft robotic organoid interface that enables programmable delivery of forces to organoids of diverse shapes, and to map electrophysiological activity and mechanical responses. The platform combines actuation elements with integrated sensors for quantitative measurement and control. Studies using this technology reveal that spheroidal cortical organoids exhibit distinct responses to mechanical trauma, including silencing, recovery, and changes in neuronal firing patterns. Additional experiments on cardiac ring tissues demonstrate that sustained stretching induces beat-to-beat rhythm variability and altered conduction. The results establish a framework for investigating force-triggered transitions between physiological and disease-like states in human tissue models.

bioengineering↗