bioRxiv Science⌕ Search

bioRxiv · 10.64898/2026.04.10.717746

From Fabrication to Flow: Impact of Print Orientation on Surface Qualities and Capillary-Driven Flow in Laser SLA-based Open Microchannels

Abstract

Stereolithography (SLA) 3D printing has become increasingly popular for fabricating microfluidic devices, with applications including hydrogel patterning and tissue modeling. In open-channel systems with surface tension-driven flow, 3D-printer-induced discrepancies in channel surface texture can significantly impact fluid flow and device performance. While previous work has focused on comparing different 3D printing methods for microchannel fabrication, the effect of device orientation during SLA printing on microchannel morphology and capillary-driven flow has not been systematically evaluated. Furthermore, there is minimal research elucidating the influence of channel surface texture on the flow of biologically relevant hydrogel precursors commonly used in organ-on-a-chip applications. Herein, we investigated the impact of print orientation on channel morphology, fluid wetting behavior, and fluid flow by comparing laser SLA-based parts where the length of the channel was tilted at 0{degrees}, 15{degrees}, 45{degrees}, or 90{degrees} during printing. We demonstrated that channel floor surface texture is greatly affected by print orientation: the highest axial surface roughness was measured in 15{degrees} printed channels, and the highest axial surface tortuosity-which describes the real length along the surface-was measured in 45{degrees} printed channels. Print angles of 15{degrees} and 45{degrees} also resulted in asymmetric roughness of the channel floor, which caused asymmetric wetting of glycerol solution. Surface tension-driven flow of glycerol solution, agarose precursor solution, and collagen precursor solution was affected by print orientation, in which the 45{degrees} printed flow devices had slowest flow for all test fluids. Root mean square roughness was not a reliable predictor of slower flow; instead, surface tortuosity should be considered. Potential alternatives to better theoretically model how print angle-induced surface texture affects open-channel flow are discussed as well. These findings provide a framework of fabrication considerations for laser SLA printing of open microchannels that can also be applied to other layer-by-layer, vat photopolymerization-based 3D printing technologies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lin, A., Milton, L., Chan, D. W. H., Ghadge, N., Tokihiro, J., Brown, L., Shin, A., Toh, Y.-C., Olanrewaju, A., Berthier, E., Berthier, J., Theberge, A.. 2026-04-14. From Fabrication to Flow: Impact of Print Orientation on Surface Qualities and Capillary-Driven Flow in Laser SLA-based Open Microchannels. https://doi.org/10.64898/2026.04.10.717746

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Single-Component Photo-Crosslinked Lipoic Acid Functionalized Mucin Hydrogels: Dynamic Mucus Mimetics for Antiviral Protection

Native mucus protects epithelial surfaces through viscoelastic networks of disulfide-linked mucins. However, commercially available mucins often fail to reconstitute comparable mechanical and barrier properties, while synthetic and hybrid mucus mimetics require polymeric crosslinkers that may alter mucus-like composition. Inspired by the native architecture, we directly functionalized porcine gastric and bovine submaxillary mucins with -lipoic acid to develop a single-component, photo-crosslinkable hydrogels. Upon UV irradiation (365 nm), the modified mucins rapidly form disulfide-crosslinked networks without added photo-initiator/ polymeric crosslinkers, two orders of magnitude faster as compared with PEG-SH approaches. The resulting mucin-lipoic acid (MUC-LA) hydrogels exhibit mucus-relevant properties, including tunable viscoelasticity, redox responsiveness, self-healing, and size-dependent restrictions on nanoparticle transport. In transwell-based infection models, MUC-LA hydrogels (2-3%) mimicking the healthy airway mucus (G' {approx} 10-20 Pa) suppress epithelial infection by SARS-CoV-2 and influenza A virus. Crosslinked MUC-LA provides greater protection against SARS-CoV-2 than the non-crosslinked, whereas both formulations suppress influenza A infection, suggesting distinct contributions from network formation and mucin-associated interactions. These findings establish a dynamic, mucus-mimetic platform integrating rapid photo-gelation, controllable mechanics, selective transport, and antiviral barrier functionality. MUC-LA hydrogels offer opportunities to investigate mucosal transport and host-pathogen interactions, with potential applications in drug delivery, and as biomaterials.

bioengineering↗

A Fibrous Optofluidic Probe for Endovascular Sensing of Blood Oxygenation and Flow Velocity

Local hemodynamic information including blood oxygenation and flow velocity could guide vascular interventions, yet obtaining these parameters in deep, narrow vessels remains challenging. Here, we report a flexible, submillimeter-scale fibrous optofluidic probe for endovascular sensing of blood oxygenation and flow velocity. The probe integrates a polymer optical fiber for light transmission with a microfluidic tube for dye injection, enabling spectroscopic oximetry and fluorescence dilution-based velocimetry through a single device. Via vascular intervention, we demonstrate local hemodynamic sensing in rabbit arteries and angiography-guided deployment in canine carotid arteries. The probe captures local changes in blood oxygenation and flow velocity during vascular occlusion and reperfusion, revealing hemodynamic disturbances that are not reflected in peripheral monitors. These results illustrate the complementary information provided by local oximetry and velocimetry and establish a compact optofluidic platform for quantitative hemodynamic monitoring during vascular interventions.

bioengineering↗

Broad-spectrum in situ genetic reprogramming of native microbiomes

Complex microbial communities are found throughout terrestrial, aquatic, and animal-associated ecosystems. Genetic modification of discrete microbial taxa within native communities represents a powerful tool to study and augment microbiome functions. Herein, we develop Synthetic Phage Assisted Reprogrammable and Targetable Addition (SPARTA) as a one-step strategy for packaging, delivering, and integrating large synthetic DNA into a broad range of native microbiomes. SPARTA leverages a broad-spectrum synthetic phage particle for in situ genome engineering within complex soil, freshwater, and mammalian fecal microbiomes, reprogramming 59 native species across 16 families. By modulating SPARTA components, we further demonstrated tunability of SPARTA towards targeted microbiome population. Additionally, we built a novel companion tool to quantitatively identify engineered taxa, named 16S crRNA-guided inference of bacterial engineering sequencing or ScRibe-seq. The SPARTA-ScRibe-seq pipeline delivered and validated functional synthetic gene clusters in diverse native microbiomes while preserving the original microbial community structure. Together, this novel genome engineering framework constitutes an end-to-end programmable platform for rational and customizable reprogramming of native microbiomes.

bioengineering↗