bioRxiv Science⌕ Search

Biology subjects

Berthier, E.

Publications and source records attributed to Berthier, E..

At least 19 recordsLinked to original sources

homeRNA Just Dropped! Streamlining Remote Blood Collection and RNA Stabilization for Smaller Sample Volumes with homeRNAdrop

At-home sampling can address obstacles to participation in transcriptomics research. We previously developed the homeRNA and homeRNAmax platforms; these custom-designed tubes containing RNA stabilizer interface with a blood tube compatible with upper-arm blood collection devices, allowing for blood collection and RNA stabilization to occur from a participant's home. In this work we introduce homeRNAdrop, an insert for a commercially available blood tube (BD Microtainer) that divides the tube into two compartments: the top compartment holds 200 L blood and the bottom compartment holds ~590 L liquid stabilizer (RNAlater). By combining blood collection and RNA stabilization into the same tube, homeRNAdrop streamlines sample preparation for participants and allows for more compact sample storage for the lab. In a remote pilot study, n=25 participants from across the United States tested the homeRNAdrop kit. The n=23 samples successfully received by the lab show that samples collected using homeRNAdrop are of sufficient RNA quality (all RINs > 6, a common cutoff for analysis) and yield (mean yield=1.44 g) for downstream gene expression analysis. Almost all participants who successfully collected blood using the Tasso Mini device found the homeRNAdrop device easy to use (n=23/24). Overall, this work adds a simplified, user-friendly platform to the growing suite of tools for remote blood RNA stabilization.

bioengineering↗

Curved by Design: Applying Microfluidic Principles for Nonplanar and Planar Suspended Tissue Patterning to the Development of Bladder Models with Tunable Mechanics

Cells in vivo exist in a complex environment where they receive chemical and physical cues from neighboring cells and the extracellular matrix. Suspended, three dimensional (3D) cell culture enables the study of mechanical signals in a controlled in vitro setting where cells can exert forces on the extracellular matrix, and mechanical stimulation can be externally applied. In addition to mechanical cues, tissues in vivo also exhibit spatial heterogeneity and nonplanar topography. To facilitate the development of suspended 3D cell culture models with both spatial and geometric complexity, we previously introduced Suspended Tissue Engineering with Assemblable Microfluidics (STEAM). STEAM is an accessible, modular platform that utilizes fluidic patterning to create multiregional planar and nonplanar suspended cell-embedded 3D tissues. Herein, we further characterize the STEAM dome platform by developing a theoretical model that explains some experimental considerations necessary for successful two-region patterning in a nonplanar construct. We highlight a brief biological application of the planar and nonplanar STEAM platforms by creating simple but physiologically relevant model systems for the bladder, a sphere-like organ with concentric tissue layers and a central lumen that dynamically expands and contracts during filling and voiding. We demonstrate that the suspended configuration of the planar bladder smooth muscle tissue patch induces inherent tension, which can be increased by further straining the tissues; both result in muscle cell alignment along the axis of stretch as shown by a clear peak at 90 degrees in a radial sum analysis of the two dimensional Fast Fourier Transform of images with fluorescent signal from myosin heavy chain 11 immunostaining. Further, we utilize the nonplanar STEAM platform with a human urothelial cell line (HBLAK) and primary bladder smooth muscle cells (HBdSMC) to create a bladder wall model, resulting in a domed, bilayered tissue. STEAM integrates patterning precision, mechanical functionality, and customizability to actualize an accessible and low cost alternative to generate spatially and geometrically complex suspended tissues.

bioengineering↗

Modeling and validation of parallel co-flows layer widths in open-capillary trigger valve systems

Control of fluids is a hallmark of microfluidic systems and fundamental for the successful application of microfluidic devices. Trigger valves use geometric features to autonomously control the release of fluids in microfluidic devices. Our previous work has adapted geometries used in closed trigger valve systems to enable use in open systems, allowing for open microfluidic devices with up to three trigger valves. Here, we focus on the parallel co-flows produced by sequential release of trigger valves and present a model that predicts their layer widths as a function of the geometric characteristics of the different side channels of each trigger valve. We show layered co-flows with widths as low as 50 microns. Additionally, we expand the use of trigger valves in open microfluidic devices by incorporating 1) varied step heights, 2) devices with up to seven trigger valves, and 3) use of varied fluids and plastics. To validate the implementation and use of these trigger valves in open systems, we have developed a theoretical framework to compare predicted outcomes (i.e., fluid travel distance, velocity, and layering width) with our experimental values. This theoretical work offers applications in various fields, including hydrogel patterning for 3D cell culture, organ-on-a-chip models, at-home sample preparation, and autonomous microfluidic systems for biosensing.

bioengineering↗

Characterization of pre-analytical blood collection and stabilization parameters to maintain endogenous protein levels for remote blood sampling technology

Blood biomarkers are central to monitoring disease progression and evaluating treatment responses, yet traditional venipuncture captures a single physiological snapshot in time and becomes burdensome with repeated sampling. Remote blood self-sampling offers a path toward longitudinal, decentralized monitoring, but maintaining protein integrity from draw to analysis remains a critical challenge. Here, we optimized pre-analytical blood collection and stabilization parameters to maintain protein levels at the time of collection for use with remote sampling technology. First, we optimized blood collection time with Tasso remote self-sampling devices to minimize interference from clotting, finding that a 2.5 min collection time best reduces clot formation while collecting enough blood. Next, we found that Protein Plus, a commercial protein stabilizer, limited hemolysis (a metric for stabilizer efficacy) in venous blood for up to 5 days at 25{degrees}C-35{degrees}C and for 1 day at 40{degrees}C. In addition, we optimized the stabilizer volume and acceptable blood volume range for self-sampling as the stabilizer efficacy is impacted by the stabilizer to blood ratio and collection volume can vary with remote self-sampling devices. Finally, we incubated stabilized blood samples collected via Tasso device at 25{degrees}C-35{degrees}C for 72 h, mimicking a 2-day shipping period. Using a panel of 21 inflammatory proteins, we found that Protein Plus limited intracellular protein release for various proteins (e.g., VEGF-A, CCL11, and IL-8), inhibited protein degradation for CCL2, and enabled minimal hemolysis. These results support Protein Plus as a viable stabilization strategy for remote blood collection technology targeting longitudinal inflammatory protein monitoring.

biochemistry↗

From Fabrication to Flow: Impact of Print Orientation on Surface Qualities and Capillary-Driven Flow in Laser SLA-based Open Microchannels

Stereolithography (SLA) 3D printing has become increasingly popular for fabricating microfluidic devices, with applications including hydrogel patterning and tissue modeling. In open-channel systems with surface tension-driven flow, 3D-printer-induced discrepancies in channel surface texture can significantly impact fluid flow and device performance. While previous work has focused on comparing different 3D printing methods for microchannel fabrication, the effect of device orientation during SLA printing on microchannel morphology and capillary-driven flow has not been systematically evaluated. Furthermore, there is minimal research elucidating the influence of channel surface texture on the flow of biologically relevant hydrogel precursors commonly used in organ-on-a-chip applications. Herein, we investigated the impact of print orientation on channel morphology, fluid wetting behavior, and fluid flow by comparing laser SLA-based parts where the length of the channel was tilted at 0{degrees}, 15{degrees}, 45{degrees}, or 90{degrees} during printing. We demonstrated that channel floor surface texture is greatly affected by print orientation: the highest axial surface roughness was measured in 15{degrees} printed channels, and the highest axial surface tortuosity-which describes the real length along the surface-was measured in 45{degrees} printed channels. Print angles of 15{degrees} and 45{degrees} also resulted in asymmetric roughness of the channel floor, which caused asymmetric wetting of glycerol solution. Surface tension-driven flow of glycerol solution, agarose precursor solution, and collagen precursor solution was affected by print orientation, in which the 45{degrees} printed flow devices had slowest flow for all test fluids. Root mean square roughness was not a reliable predictor of slower flow; instead, surface tortuosity should be considered. Potential alternatives to better theoretically model how print angle-induced surface texture affects open-channel flow are discussed as well. These findings provide a framework of fabrication considerations for laser SLA printing of open microchannels that can also be applied to other layer-by-layer, vat photopolymerization-based 3D printing technologies.

bioengineering↗

To the homeRNAmax: Developing an Improved Blood Self-Collection and Stabilization Platform for Remote Transcriptomic Studies

Shifting human subjects research from research sites to participants homes removes barriers to participation, including transportation and scheduling difficulties. Previously, we developed homeRNA, a kit for immediate stabilization of RNA in self-collected blood using a custom-engineered tube containing RNA stabilizer fluid. The stabilized RNA is extracted and used for downstream gene expression analysis. Here, we introduce homeRNAmax, which improves our original design by interfacing with a commercially available blood collection tube (BD Microtainer), allowing homeRNAmax to be used with any blood collection method that uses this tube and doubling the possible sample volume that can be collected and stabilized compared to the original homeRNA. Through a pilot study (n=19 participants), we show that homeRNAmax (with the Tasso+ blood collection device) produces RNA samples of sufficient quality (mean RIN=7.8) and yield (mean yield=1.93 g) for downstream analysis and can reach participants across the United States, who generally (n=17/19) found the homeRNAmax kit easy to use. A key aspect of the homeRNA and homeRNAmax platforms is a fluidic feature that prevents the RNA stabilizer from spilling, however our previous work had not yet fully characterized the mechanism of this feature. Here, we developed a theoretical model of the spill-resistant feature. In brief, fluid in the tube is suspended due to a balance of pressures; an increase in air volume within the tube reduces the air pressure above the fluid, creating a small vacuum, and preventing fluid leakage. Overall, we show that homeRNAmax is a user-friendly, effective tool for remote blood RNA stabilization.

bioengineering↗

Suspended Tissue Engineering with Assemblable Microfluidics (STEAM)

Suspended tissue culture systems enable cellular responses to mechanical forces critical for tissue development and function. Tissues develop in complex environments containing both mechanical and chemical cues that vary spatiotemporally; thus modeling both of these physiochemistries in vitro through integration of spatial patterning with mechanical manipulation simultaneously is an important aspect in microphysiological tissue modeling which has yet to be achieved. Here, we introduce Suspended Tissue Engineering with Assemblable Microfluidics (STEAM), a modular tissue fabrication platform that allows for spatially heterogeneous suspended tissue architectures. With STEAM, we achieve tissue constructs with multiple regions through the addition of capillary pinning features to control hydrogel precursor flow. STEAM tissues can easily be moved from patterning setup to well-plate to microscope slide, which also enables stacking of separately generated layers. Mechanical manipulation post-fabrication is also possible via static stretching, where cell-embedded 3D tissues can be stretched farther apart to induce strain along an axis. To demonstrate the utility of post fabrication strain ability, we showed that myotube alignment increases when strain is applied to STEAM generated engineered muscle tissue containing mouse myoblasts. Finally, by modifying the channel geometry of the fluidic-based patterning rails, we generate complex nonplanar suspended tissues. STEAM leverages microfluidic principles to generate suspended tissues that integrate patterning precision, mechanical functionality, and experimental versatility, providing a suite of construct combinations for modeling tissue behaviors from the interplay of spatial organization and mechanical forces.

bioengineering↗

From Home to Transcriptome: Comparing the transcriptomic profile of induced immune response via lipopolysaccharide stimulation in homeRNA and venous blood

Remote blood sampling offers multiple advantages over traditional clinic-based blood sampling studies, including greater patient inclusion, more frequent sampling, and broader geographical reach. Combining remote blood sampling with transcriptomic analysis opens potential in translational applications for capturing acute and dynamic immune responses to various exposures. In this study, we establish the feasibility of homeRNA, a capillary blood collection and RNAlater-based stabilization kit, for use in downstream bulk RNA-sequencing applications via capturing a lipopolysaccharide (LPS)-induced inflammatory response. We also compared the baseline gene expression profiles and induced inflammatory response following LPS stimulation between homeRNA-stabilized samples and venous blood stabilized with RNAlater or PAXgene. We found that homeRNA was successfully able to capture an inflammatory response to LPS, specifically targeting various cytokines (e.g., IL6, IL12B, IL1B), chemokines (e.g., CCL3, CXCL10, CCL4), and other transcriptional factors in the toll-like receptor pathway, the primary pathway activated during LPS stimulation. Importantly, we also found that homeRNA captured a LPS-induced inflammatory response comparable to that of venous blood samples stabilized with either RNAlater or PAXgene. Overall, this work demonstrates that the homeRNA platform is compatible with downstream bulk RNA-sequencing analysis and can capture transcriptomic immune responses to a known stimulus which are analogous to results in traditional stabilized venous blood samples.

bioengineering↗

Detection of inertial effects in capillary flows in open and closed channels

The Lucas-Washburn-Rideal law is commonly applied to describe capillary flow dynamics in closed or open channels, microporous media, such as paper pads and fiber threads or even granulous soil. It assumes a viscous flow regime where capillary forces are counteracted by friction with the solid structure, a valid assumption given the small flow velocities and device dimensions. However, scenarios exist outside the viscous regime, where inertial effects become significant, meaning capillary and friction forces do not fully balance. One well-documented case is the transient inertial regime at the onset of capillary motion. With the advancement of capillary devices, other configurations also raise the possibility of inertia influencing flow behavior. This study introduces a criterion to identify inertial contributions in capillary-driven flows in spatially varying geometries within open or closed channels and demonstrates how the Bosanquet equation can account for inertial effects in rectangular open-channel configurations.

bioengineering↗

CandyCollect Open to Closed (O2C) Microfluidic System for Rapid and User-Centric Detection of Group A Streptococcus

We created CandyCollect, a lollipop-inspired, child-friendly saliva sampling device that provides enhanced comfort compared to common throat and mouth swabs. The device has an open microchannel and a functionalized surface that effectively captures and stores the saliva and pathogens. We recently demonstrated the ability to combine the CandyCollect with rapid antigen detection tests (RADTs) for fast and accessible detection of group A streptococcus (GAS). However, the current procedure necessitates manual steps to elute and transfer captured antigens from the lollipop to RADTs, which relies on the user to follow complex instructions, increasing the likelihood of error. In this work, we developed the CandyCollect Open to Closed (O2C) microfluidic system to automate antigen elution and streamline detection with RADTs. The O2C system securely seals the open microchannels of the CandyCollect device to create a continuous closed channel for seamless delivery of elution reagents to release antigens at the press of a button for subsequent lateral flow detection. Our system leverages and combines the unique benefits of both open channel and closed channel microfluidics into one platform, further enhancing the potential of both methods. We performed experiments with GAS bacteria spiked into saliva and compared the manual and O2C elution methods. Both the manual and O2C methods showed clear test lines on the RADT strips at clinically relevant GAS concentrations (between 5 x105 and 109 CFU/mL). The O2C provided comparable or better results than the manual procedure in a more convenient form factor. The O2C platform has the potential to enable user-friendly screening for respiratory pathogens by minimally trained users in decentralized settings.

bioengineering↗

CandyCollect: An Open-Microfluidic Device for the Direct Capture and Enumeration of Salivary-Extracellular Vesicles

Extracellular vesicles (EVs) are promising biomarkers for disease detection using a liquid biopsy approach, in which they are enriched and analyzed directly from biofluids. However, implementing EV biomarker technologies in the clinic remains limited by the need for practical and patient-centric biofluid collection methods that are compatible with downstream EV processing and analysis. While saliva offers a non-invasive source of EVs, its complexity and heterogeneity--cells, debris, and other non-EV proteins--can present hurdles when using traditional analytical platforms. Here, we present the CandyCollect, a lollipop-inspired sampling device with open microfluidic channels, as a patient-friendly approach for rapid salivary EV capture. CandyCollect simplifies sample preparation by effectively pre-concentrating EVs in oxygen-plasma treated open microfluidic channels. In this proof-of-principle study, we show that following a 3-5 minute-oral sampling period, EVs collected by the CandyCollect can be released with high purity within minutes and subsequently quantified and analyzed for cargo content. We observed consistent EV capture across repeated collections within individuals and expected variability across healthy participants. Additionally, single and pooled collections of EVs from a healthy participant resulted in a concordant protein profile. Overall, the CandyCollect is a new platform for rapid, non-invasive salivary EV collection and analysis for clinical diagnostics.

bioengineering↗

Suspended Tissue Open Microfluidic Patterning (STOMP)

Free-standing tissue structures tethered between pillars are powerful mechanobiology tools for studying cell contraction. To model interfaces ubiquitous in natural tissues and upgrade existing single-region suspended constructs, we developed Suspended Tissue Open Microfluidic Patterning (STOMP), a method to create multi-regional suspended tissues. STOMP uses open microfluidics and capillary pinning to pattern subregions within free-standing tissues, facilitating the study of complex tissue interfaces, such as diseased-healthy boundaries (e.g., fibrotic-healthy) and tissue-type interfaces (e.g., bone-ligament). We observed altered contractile dynamics in fibrotic-healthy engineered heart tissues compared to single-region tissues and differing contractility in bone-ligament enthesis constructs compared to single-tissue periodontal ligament models. STOMP is a versatile platform - surface tension-driven patterning removes material requirements common with other patterning methods (e.g., shear-thinning, photopolymerizable) allowing tissue generation in multiple geometries with native extracellular matrices and advanced 4D materials. STOMP combines the contractile functionality of suspended tissues with precise patterning, enabling dynamic and spatially controlled studies.

bioengineering↗

The dynamics of capillary flow in an open-channel system featuring trigger valves

Trigger valves are fundamental features in capillary-driven microfluidic systems that stop fluid at an abrupt geometric expansion and release fluid when there is flow in an orthogonal channel connected to the valve. The concept was originally demonstrated in closed-channel capillary circuits. We show here that trigger valves can be successfully implemented in open channels. We also show that a series of open-channel trigger valves can be placed alongside or opposite a main channel resulting in a layered capillary flow. We developed a closed form model for the dynamics of the flow at trigger valves based on the concept of average friction length and successfully validated the model against experiments. For the main channel, we discuss layered flow behavior in the light of the Taylor-Aris dispersion theory and in the channel turns by considering Dean theory of mixing. This work has potential applications in autonomous microfluidics systems for biosensing, at-home or point-of-care sample preparation devices, hydrogel patterning for 3D cell culture and organ-on-a-chip models.

bioengineering↗

Your Blood is Out for Delivery: Considerations of Shipping Time and Temperature on Degradation of RNA from Stabilized Whole Blood

Remote research studies are an invaluable tool for reaching populations in geographical regions with limited access to large medical centers or universities. To expand the remote study toolkit, we have previously developed homeRNA, which allows for at-home self-collection and stabilization of blood and demonstrated the feasibility of using homeRNA in high temperature climates. Here, we expand upon this work through a systematic study exploring the effects of high temperature on RNA integrity through in-lab and field experiments. Compared to the frozen controls (overall mean RIN of 8.2, n = 8), samples kept at 37{degrees}C for 2, 4, and 8 days had mean RINs of 7.6, 5.9, and 5.2 (n = 3), respectively, indicating that typical shipping conditions ([~]2 days) yield samples suitable for downstream RNA sequencing. Shorter time intervals (6 hours) resulted in minimal RNA degradation (median RIN of 6.4, n = 3) even at higher temperatures (50{degrees}C) compared to the frozen control (mean RIN of 7.8, n = 3). Additionally, we shipped homeRNA-stabilized blood from a single donor to 14 different states and back during the summer with continuous temperature probes (7.1 median RIN, n = 42). Samples from all locations were analyzed with 3 mRNA-seq to assess differences in gene counts, with the transcriptomic data suggesting that there was no preferential degradation of transcripts as a result of different shipping times, temperatures, and regions. Overall, our data support that homeRNA can be used in elevated temperature conditions, enabling decentralized sample collection for telemedicine, global health, and clinical research.

bioengineering↗

Open-Channel Droplet Microfluidic Platform for Passive Generation of Human Sperm Microdroplets

Sperm cryopreservation is important for many individuals across the globe. Recent studies show that vitrification is a valuable approach for maintaining sperm quality after freeze-thawing processes and requires sub-microliter to microliter volumes. A major challenge for the adoption of vitrification in fertility laboratories is the ability to pipette small volumes of sample. Here, we present an open droplet generator that leverages open-channel microfluidics to passively generate sub-microliter to microliter volumes of purified human sperm samples and preserves sperm kinematics. We conclude that our platform is compatible with human sperm, an important foundation for future implementation of vitrification in fertility laboratories. Table of contents artwork O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=108 SRC="FIGDIR/small/593416v3_ufig1.gif" ALT="Figure 1"> View larger version (24K): org.highwire.dtl.DTLVardef@1733ae0org.highwire.dtl.DTLVardef@1e638aorg.highwire.dtl.DTLVardef@119097forg.highwire.dtl.DTLVardef@be86f3_HPS_FORMAT_FIGEXP M_FIG C_FIG

bioengineering↗

At-home oral bacteria collection using a lollipop-based microfluidic device

Respiratory infections are common in children, and there is a need for user-friendly collection methods. Here, we performed the first human subjects study using the CandyCollect device, a lollipop inspired saliva collection device.1 We showed the CandyCollect device can be used to collect salivary bacteria from healthy adults using Streptococcus mutans and Staphylococcus aureus as proof-of-concept commensal bacteria. We enrolled healthy adults in a nationwide (USA) remote study in which participants were sent study packages containing CandyCollect devices and traditional commercially available oral swabs and spit tubes. Participants sampled themselves at home, completed usability and user preference surveys, and mailed the samples back to our laboratory for analysis by qPCR. Our results showed that for participants in which a given bacterium (S. mutans or S. aureus) was detected in one or both of the commercially available methods (oral swab and/or spit tubes), CandyCollect devices had a 100% concordance with the positive result (n=14 participants). Furthermore, the CandyCollect device was ranked the highest preference sampling method among the three sampling methods by 26 participants surveyed (combining survey results across two enrollment groups). We also showed that the CandyCollect device has a shelf life of up to 1 year at room temperature, a storage period that is convenient for clinics or patients to keep the CandyCollect device and use it any time. Taken together, we have demonstrated that the CandyCollect is a user-friendly saliva collection tool that has the potential to be incorporated into diagnostic assays in clinic visits and telemedicine. For Table of Contents Only O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=126 SRC="FIGDIR/small/524039v6_ufig1.gif" ALT="Figure 1"> View larger version (37K): org.highwire.dtl.DTLVardef@1356b32org.highwire.dtl.DTLVardef@10c737org.highwire.dtl.DTLVardef@1872455org.highwire.dtl.DTLVardef@1625069_HPS_FORMAT_FIGEXP M_FIG C_FIG

biochemistry↗

Enhanced capillary pumping using open-channel capillary trees with integrated paper pads

The search for efficient capillary pumping has led to two main directions for investigation: first, assembly of capillary channels to provide high capillary pressures, and second, imbibition in absorbing fibers or paper pads. In the case of open microfluidics (i.e., channels where the top boundary of the fluid is in contact with air instead of a solid wall), the coupling between capillary channels and paper pads unites the two approaches and provides enhanced capillary pumping. In this work, we investigate the coupling of capillary trees-- networks of channels mimicking the branches of a tree--with paper pads placed at the extremities of the channels, mimicking the small capillary networks of leaves. It is shown that high velocities and flow rates (7 mm/s or 13.1 {micro}L/s) for more than 30 seconds using 50% (v/v) isopropyl alcohol, which has a 3-fold increase in viscosity in comparison to water; 6.5 mm/s or 12.1 {micro}L/s for more than 55 seconds with pentanol, which has an 3.75-fold increase in viscosity in comparison to water; >3.5 mm/s or 6.5 {micro}L/s for more than 150 seconds with nonanol, which has an 11-fold increase in viscosity in comparison to water) can be reached in the root channel, enabling higher sustained flow rates than that of capillary trees alone.

bioengineering↗

An Open Microfluidic Coculture Model of Fibroblasts and Eosinophils to Investigate Mechanisms of Airway Inflammation

Interactions between fibroblasts and immune cells play an important role in tissue inflammation. Previous studies have found that eosinophils activated with interleukin-3 (IL-3) degranulate on aggregated immunoglobulin G (IgG) and release mediators that activate fibroblasts in the lung. However, these studies were done with eosinophil-conditioned media that have the capacity to investigate only one-way signaling from eosinophils to fibroblasts. Here, we demonstrate a coculture model of primary normal human lung fibroblasts (HLFs) and human blood eosinophils from patients with allergy and asthma using an open microfluidic coculture device. In our device, the two types of cells can communicate via two-way soluble factor signaling in the shared media while being physically separated by a half wall. Initially, we assessed the level of eosinophil degranulation by their release of eosinophil-derived neurotoxin (EDN). Next, we analyzed the inflammation-associated genes and soluble factors using reverse transcription quantitative polymerase chain reaction (RT-qPCR) and multiplex immunoassays, respectively. Our results suggest an induction of a proinflammatory fibroblast phenotype of HLFs following the coculture with degranulating eosinophils, validating our previous findings. Additionally, we present a new result that indicate potential impacts of activated HLFs back on eosinophils. This open microfluidic coculture platform provides unique opportunities to investigate the intercellular signaling between the two cell types and their roles in airway inflammation and remodeling.

cell biology↗