bioRxiv Science⌕ Search

bioRxiv · 10.1101/851493

An electrostatic-interaction-based mechanism triggering misfolding of prion proteins from cellular isoform to scrapie isoform

Abstract

Understanding how prion proteins refold from a cellular isoform (PrPC) to a disease-causing isoform (PrPSc) has been among the "ultimate challenges" in molecular biology, biophysics, pathology, and immunology. Conformational changes of prion proteins from PrPC to PrPSc involve the unfolding of a short -helix that overshadows the challenge. Considering the mechanisms of electrostatic attraction, thermal disturbance, hydrogen ion concentration, hydrophobic interaction, and the shielding effect of water molecules, this study reveals an electrostatic-interaction-based mechanism by means of which prion proteins refold in an aqueous environment. The electrostatic-interaction-induced protein unfolding mechanism causes a hydrophobic polypeptide segment to dangle out over the conglobate main body of the prion protein, thereby allowing the first triangular hydrophobic rung formation via hydrophobic interaction. A molecular model of PrPSc is proposed that allows the {beta}-solenoid with a triangular hydrophobic core. Statement of SignificanceWe present three main results that would revolutionize the understanding of pathology of prion diseases. First, the prion protein refolding (from cellular isoform to scrapie isoform) derives from the unfolding of the shortest -helix of PrPC, which provides a long polypeptide segment full of hydrophobic residues dangling out over the conglobate main body of the prion protein, thereby allowing formation of the first triangular hydrophobic rung via hydrophobic interaction. Second, polyanions-induced increasing in local concentration of hydrogen ion (i.e., the PH increase) undermines the shielding effect of water molecules, thereby allowing escape of the arginine side chains from the hydration shell, destabilizing the shortest -helix and initiating the refolding of PrPC. Third, a {beta}-solenoid structural model for PrPSc with a triangular hydrophobic core is proposed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yang, L., Li, J., Ma, X., Guo, S., Hou, C., Shi, L., Ye, L., Zheng, B., He, X.. 2019-11-21. An electrostatic-interaction-based mechanism triggering misfolding of prion proteins from cellular isoform to scrapie isoform. https://doi.org/10.1101/851493

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Semidilute Polymer Scaling Controls PEG-induced Protein Phase Separation

When does polyethylene glycol (PEG) mass concentration provide a common measure of crowding strength across polymer chain lengths? Here we use bovine serum albumin (BSA) and PEG as a controlled depletion system and measure both coexisting phases to determine binodals, tie lines, and critical points across PEG molecular weights of 4--100 kDa. Phase diagrams for PEG 20, 35, and 100 kDa approximately collapse in mass-concentration coordinates, consistent with semidilute polymer scaling. Generalized free volume theory (GFVT) describes the BSA binodals and tie lines. It also approximately describes binodals for three additional globular proteins in PEG 35K, extending the comparison across proteins spanning 7.2--66.4 kDa. For the binary PEG mixtures tested, GFVT approximates the binodals using an effective polymer size corresponding to the weight-average molecular weight. These results identify a regime in which PEG mass concentration (g/L) provides a transferable measure of depletion-induced crowding.

biophysics↗

Correlation-resolved sum-frequency generation microscopy of biological tissue with bright twin beams

Sum-frequency generation (SFG) driven by bright twin beams generated through high-gain parametric down-conversion comprises a coherent component arising from correlated mode pairs and an incoherent component arising from interactions between uncorrelated modes. Modal correlations can enhance coherent SFG in anisotropic nonlinear media, for example by extending the effective interaction length. Whether such correlations can likewise benefit image formation in heterogeneous biological tissue remains unknown. Here we address this question by performing SFG imaging of biological tissue using bright twin beams as the excitation source. Spectral decomposition of the SFG signal separates its coherent and incoherent components, allowing us to reconstruct co-registered images and examine how twin-beam correlations influence image formation. In mouse skeletal muscle, the coherent-component image revealed sarcomere periodicity with a Bragg-spot-to-background ratio of approximately 310, compared with 7.5 in the incoherent-component image. In fresh human dermis, the coherent-component image showed greater Fourier power than the incoherent-component image in the 0.30-0.50 \mu m^{-1} band and a greater fractional autocovariance decay at short spatial lags. These results demonstrate that twin-beam correlations can enhance contrast and detectability at selected spatial frequencies in heterogeneous tissue. Correlation-resolved SFG microscopy thus offers a route for exploiting bright quantum-light sources in nonlinear optical bioimaging.

biophysics↗

Polarization affects viscoelasticity and podosome distribution of primary human macrophages

Macrophages are essential cells of the innate immune system that regulate wound healing and tissue homeostasis. They exert diverse functions, depending on their polarization state, which can lead to either functional healing of the tissue or fibrosis. Macrophage polarization state is affected by both the local biochemical and mechanical microenvironment within the tissue, suggesting a possible dependence of macrophage function on cell mechanical state, which has been poorly explored to date. In this study, we provide a systematic and quantitative characterization of the viscoelastic properties of unstimulated, pro-inflammatory, and anti-inflammatory monocyte-derived primary human macrophages at the single-cell level using atomic force microscopy. Pro-inflammatory macrophages exhibited a lower elastic modulus (E = 458.8 {+/-} 179.9 Pa) and a more dissipative response (low frequency exponent = 0.22 {+/-} 0.03) than anti-inflammatory macrophages (E = 716 {+/-} 345.6 Pa and = 0.15 {+/-} 0.04). These differences in mechanical properties were independent of cell morphology but correlated with differences in podosome distribution with pro-inflammatory macrophages exhibiting a dispersed distribution, and anti-inflammatory macrophages a more clustered distribution. This study identifies polarization-dependent mechanical differences in human primary macrophages and provides a quantitative experimental framework for future work in macrophage mechanobiology.

biophysics↗