bioRxiv Science⌕ Search

bioRxiv · 10.1101/274753

Deep mutational scanning by FACS-sorting of encapsulated E. coli micro-colonies

Abstract

We present a method for high-throughput screening of protein variants where the signal is enhanced by micro-encapsulation of single cells into 20-30 m agarose beads. Cells inside beads are propagated using standard agitation in liquid media and grow clonally into micro-colonies harboring several hundred bacteria. We have, as a proof-of-concept, analyzed random amino acid substitutions in the five C-terminal {beta}-strands of the Green Fluorescent Protein (GFP). Starting from libraries of variants, each bead represents a clonal line of cells that can be separated by Fluorescence Activated Cell Sorting (FACS). Pools representing collections of individual variants with desired properties are subsequently analyzed by deep sequencing. Notably, the encapsulation approach described holds the potential for high-throughput analysis of systems where the fluorescence signal from a single cell is insufficient for detection. Fusion to GFP, or use of fluorogenic substrates, allows coupling protein levels or activity to sequence for a wide range of proteins. Here we analyzed more than 10,000 individual variants to gauge the effect of mutations on GFP-fluorescence. In the mutated region, we observed virtually all amino acid substitutions that are accessible by single nucleotide exchange. Lastly, we assessed the performance of biophysical protein stability predictors, FoldX and Rosetta, in predicting the outcome of the experiment. Both tools display good performance on average, suggesting that loss of thermodynamic stability is a key mechanism for the observed variation of the mutants. This, in turn, suggests that deep mutational scanning datasets may be used to more efficiently fine-tune such predictors, especially for mutations poorly covered by current biophysical data.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Behrendt, L., Stein, A., Shah, S. A., Zengler, K., Sorensen, S. J., Lindorff-Larsen, K., Winther, J. R.. 2018-03-02. Deep mutational scanning by FACS-sorting of encapsulated E. coli micro-colonies. https://doi.org/10.1101/274753

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Impaired loading following denervation elicits dynamic, differential growth trajectories of musculoskeletal tissues

Physical forces dictate the function and maintenance of adult musculoskeletal tissues. Yet, the impact of biophysical cues on the growth and maturation of these tissues, especially dense connective tissues, remains unclear. Here, we investigated the effects of neonatal mechanical loading on early postnatal growth of the musculoskeletal tissues of the lower limb, with particular focus on the Achilles tendon. We performed sciatic nerve resection (SNR) on one-day-old mice to denervate the hamstrings and distal hindlimb muscles. Sciatic Nerve Resection resulted in severe and sustained alterations in gait, accompanied by an altered transcriptional landscape in distal musculoskeletal tissues, with marked reductions in bone and tendon growth and smaller, fibrotic hindlimb musculature. Sciatic nerve resection impaired cumulative growth in the Achilles tendon, shifting cell proliferation and matrix-driven growth trajectories and altering mechanotransduction gene programs toward inflammation and matrix catabolism with age. This work highlights the essential role of mechanical loading in driving mechanosignaling and postnatal growth trajectories in musculoskeletal tissues of the developing limb, with implications for overall musculoskeletal health in adulthood.

bioengineering↗

MiniMAP: An automatic pipeline for paediatric lower limb musculoskeletal model generation

The generation of paediatric musculoskeletal models often requires compromise between data availability, accuracy, and computation time. Statistical shape models allow for rapid generation of bone geometries for use in musculoskeletal modelling. An articulated shape model allows for movement at the joints during optimisation to better fit to experimental data. Here we present a methodology for generating custom paediatric OpenSim models using an articulated shape model of the lower limb generated from CT scans of over 300 children aged 4 to 18 years old. Bone geometries are predicted using demographic factors (age, height, mass, and sex), linear bone measurements (bone widths and lengths), and 12 skin surface landmarks (L/R ASIS, L/R PSIS, medial/lateral epicondyles, and medial/lateral malleoli). To account for skin padding (bone to skin surface distance) a random forest algorithm was developed for skin padding prediction for these 12 landmarks. Accuracy of the model prediction was assessed using a leave-one-out analysis to assess landmark errors, bone surface errors, and clinical bone measurement errors (linear measurements and angular values). Motion capture and MRI data were collected from two paediatric test cases to test the workflow on unseen data. Skin padding values varied widely in this population with average values from 3.4mm at the lateral malleolus to 25.9mm at the PSIS. Skin padding was best predicted using age, height, mass, ASIS width, epicondylar width, and malleolar width with an average RMSE of 4.68mm. The articulated shape model predicted accurate bone geometries from skin surface landmarks with average bone surface RMSEs of 2.64 {+/-} 0.99mm, 1.91 {+/-} 0.59mm, and 1.69 {+/-} 0.56mm in the pelvis, femora, and tibiae/fibulae respectively. In the two unseen test cases, average bone surface errors ranged from 1.64 {+/-} 1.2mm to 3.41 {+/-} 3.1mm. This study demonstrated the accuracy of "MiniMAP", for the rapid generation of custom paediatric musculoskeletal models.

bioengineering↗

A single-plane electrical impedance tomography framework for integrated liver and kidney assessment

Chronic liver and kidney diseases frequently coexist, but their assessment typically requires separate clinical workflows involving serum-based estimated glomerular filtration rate (eGFR) testing and liver elastography-based controlled attenuation parameter (CAP). Electrical impedance tomography (EIT) has recently shown promise for providing portable, non-invasive proxies for both reference measurements. However, existing multi-organ EIT assessment still requires different acquisition protocols for each organ. To simplify this procedure, we assessed the feasibility of a single-plane EIT framework for reconstructing organ-specific images and estimating liver and kidney health from one abdominal belt placement. Across diverse abdominal belt locations, opposite-plane deviation was significantly greater for eGFREIT estimates (2.92%; IQR, 0.46-12.53%) than for CAPEIT estimates (0.94%; IQR, 0.66-1.70%) (p < 0.01). For both organs, compared to images acquired at the conventional organ-specific planes, image correlation significantly decreased (both, p < 0.05) and normalized root mean squared error significantly increased (both, p < 0.05) at the furthest imaging plane, with these differences being numerically larger for the kidney. Together, these results supported the kidney plane as the preferred location for multi-organ assessment. Test-retest evaluation after belt removal and reapplication demonstrated that the correlation between two repeated CAPEIT estimates was just as strong at the kidney plane (R2 = 0.98, p < 0.001) as it was at the conventional liver plane (R2 = 0.97, p < 0.001). Finally, in an independent clinical cohort, kidney-plane CAPEIT estimates were significantly higher in participants with a high metabolic liver-risk profile (i.e. diabetes and high blood pressure) (p < 0.005). CAPEIT estimates also distinguished high and low metabolic risk groups with an AUC of 0.756. Together, these findings support the feasibility of a portable multi-organ EIT imaging framework capable of extracting complementary liver and kidney information from a single belt placement.

bioengineering↗