bioRxiv Science⌕ Search

bioRxiv · 10.1101/215566

Spin coated chitin films for biosensors and its analysis are depended on chitin-surface interactions

Abstract

Chitin, abundant in nature, is a renewable resource with many possible applications in bioengineering. Biosensors, capable of label-free and in-line evaluation, play an important role in the investigation of chitin synthesis, degradation and interaction with other materials. This work presents a comparative study of the usefulness of a chitin surface preparation, either on gold (Au) or on polystyrene (PS). In both cases the most common method to dissolve chitin was used, followed by a simple spin-coating procedure. Multi-parametric surface plasmon resonance (MP-SPR), modeling of the optical properties of the chitin layers, scanning electron microscopy, and contact angle goniometry were used to confirm: the thickness of the layers in air and buffer, the refractive indices of the chitin layers in air and buffer, the hydrophobicity, the binding properties of the chitin binding domain (CBD) of Bacillus circulans, and the split-intein capture process. Binding of the CBD differed between chitin on Au versus chitin on PS in terms of binding strength and binding specificity due to a less homogenous structured chitin-surface on Au in comparison to chitin on PS, despite a similar thickness of both chitin layers in air and after running buffer over the surfaces. The use of the simple method to reproduce chitin films on a thin polystyrene layer to study chitin as a biosensor and for chitin binding studies was obvious from the SPR studies and the binding studies of CBD as moiety of chitinases or as protein fusion partner. In conclusion, stable chitin layers for SPR studies can be made from chitin in a solution of dimethylacetamide (DMA) and lithium chloride (LiCl) followed by spin-coating if the gold surface is protected with PS.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Casteleijn, M. G., Richardson, D., Parkkila, P. K., Granqvist, N., Urtti, A., Viitala, T.. 2017-11-07. Spin coated chitin films for biosensors and its analysis are depended on chitin-surface interactions. https://doi.org/10.1101/215566

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Kinetic gating by an iron sulfur chain modulates flavin radical-pair spin chemistry in mitochondrial Complex I

Mitochondrial Complex I generates reactive oxygen species at its flavin cofactor, where spin dependent reaction pathways have been proposed. Models of this chemistry treat the flavin oxygen radical pair in isolation, although the flavin is wired to a chain of eight iron sulfur clusters. Here we model the pair with this chain using the human Complex I structure and open quantum system models of spin coupling and electron transfer. In the simulated network, spin coherence decays rapidly along the chain, whereas proximal clusters alter the calculated radical-pair singlet yield. Their influence is kinetically gated: a downstream cluster affects the modelled yield when its electron-transfer rate competes with radical pair recombination, a threshold robust to driving force and to the transfer model. Modelling does set the sign: one directional spin hops predict suppression and inflate coherence transport, whereas charge resolved transfer drives the singlet yield towards its spin-randomized limit unless triplet recombination dominates. Detectable spin dependent effects in this framework require superoxide spin relaxation to be substantially slower than in free solution, a condition not yet established for Complex I.

biophysics↗

Semidilute Polymer Scaling Controls PEG-induced Protein Phase Separation

When does polyethylene glycol (PEG) mass concentration provide a common measure of crowding strength across polymer chain lengths? Here we use bovine serum albumin (BSA) and PEG as a controlled depletion system and measure both coexisting phases to determine binodals, tie lines, and critical points across PEG molecular weights of 4--100 kDa. Phase diagrams for PEG 20, 35, and 100 kDa approximately collapse in mass-concentration coordinates, consistent with semidilute polymer scaling. Generalized free volume theory (GFVT) describes the BSA binodals and tie lines. It also approximately describes binodals for three additional globular proteins in PEG 35K, extending the comparison across proteins spanning 7.2--66.4 kDa. For the binary PEG mixtures tested, GFVT approximates the binodals using an effective polymer size corresponding to the weight-average molecular weight. These results identify a regime in which PEG mass concentration (g/L) provides a transferable measure of depletion-induced crowding.

biophysics↗

Correlation-resolved sum-frequency generation microscopy of biological tissue with bright twin beams

Sum-frequency generation (SFG) driven by bright twin beams generated through high-gain parametric down-conversion comprises a coherent component arising from correlated mode pairs and an incoherent component arising from interactions between uncorrelated modes. Modal correlations can enhance coherent SFG in anisotropic nonlinear media, for example by extending the effective interaction length. Whether such correlations can likewise benefit image formation in heterogeneous biological tissue remains unknown. Here we address this question by performing SFG imaging of biological tissue using bright twin beams as the excitation source. Spectral decomposition of the SFG signal separates its coherent and incoherent components, allowing us to reconstruct co-registered images and examine how twin-beam correlations influence image formation. In mouse skeletal muscle, the coherent-component image revealed sarcomere periodicity with a Bragg-spot-to-background ratio of approximately 310, compared with 7.5 in the incoherent-component image. In fresh human dermis, the coherent-component image showed greater Fourier power than the incoherent-component image in the 0.30-0.50 \mu m^{-1} band and a greater fractional autocovariance decay at short spatial lags. These results demonstrate that twin-beam correlations can enhance contrast and detectability at selected spatial frequencies in heterogeneous tissue. Correlation-resolved SFG microscopy thus offers a route for exploiting bright quantum-light sources in nonlinear optical bioimaging.

biophysics↗