bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.06.28.662133

Mapping the Fascicular Morphology and Organization of the Human Sciatic Nerve via High-Resolution MicroCT Imaging

Abstract

ObjectiveImplanted neuroprostheses can restore standing and walking after spinal cord injury and somatosensation after limb loss. Yet current approaches often fail to reliably activate hamstring muscles crucial for upright stability and mobility or to target afferent fibers for sensory restoration. We developed a novel methodology using high-resolution micro-computed tomography (microCT) to visualize and track fascicle groups innervating distinct hamstring muscles along the human sciatic nerve. This approach provides a framework for mapping fascicular topography in complex neural pathways to optimize standing neuroprostheses. MethodsBilateral sciatic nerves were dissected and excised from an embalmed human cadaver, annotated with branch names, and stained with phosphotungstic acid before undergoing microCT scanning at 11.4 m isotropic resolution. Images were segmented with a 3D U-Net convolutional neural network. Segmentation results were used to quantify morphological metrics and track fascicular organization along [~]25 cm of the nerve. MicroCT reconstructions were validated against histological cross sections. ResultsGross dissection revealed matched proximal-to-distal branching between left and right sciatic nerves: branch to long head of the biceps femoris (lhBF), branch to hamstring part of the adductor magnus and semimembranosus (HAM/SM), and branch to semitendinosus (ST). All branches originated medially and followed an inferomedial trajectory. Branch-free lengths of the sciatic exhibited asymmetry, especially between the lumbosacral roots to the first branch (5.5 cm left vs. 1.5 cm right) and lhBF to the HAM/SM branch (9.0 cm left vs. 16.5 cm right). MicroCT analysis revealed bilateral symmetry in fascicle diameters ([~]0.4 mm) and total fascicle counts ([~]84) but asymmetry in hamstring-innervating fascicle counts (left [~]7, right: [~]9). The 3D fascicular maps revealed that hamstring fascicles were located in the anteromedial portion of the sciatic nerve cross section and remained separate for distances up to 15.9 cm proximal to their branching points. SignificanceOur microCT-based approach enables efficient, high-resolution 3D mapping of fascicular organization within large, complex peripheral nerves like the sciatic nerve, overcoming previous technical limitations. This methodology informs development of neuroprostheses with improved hamstring muscle activation for enhanced standing function.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Zhang, J., Lam, V. H., Nuzov, N. B., Brunsman, B. A. S., Pascol, T., Onabiyi, A., Prince, R., Kalpatthi, H., Gustafson, K., Triolo, R., Pelot, N. A., Crofton, A., Shoffstall, A. J.. 2025-07-03. Mapping the Fascicular Morphology and Organization of the Human Sciatic Nerve via High-Resolution MicroCT Imaging. https://doi.org/10.1101/2025.06.28.662133

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Single-Component Photo-Crosslinked Lipoic Acid Functionalized Mucin Hydrogels: Dynamic Mucus Mimetics for Antiviral Protection

Native mucus protects epithelial surfaces through viscoelastic networks of disulfide-linked mucins. However, commercially available mucins often fail to reconstitute comparable mechanical and barrier properties, while synthetic and hybrid mucus mimetics require polymeric crosslinkers that may alter mucus-like composition. Inspired by the native architecture, we directly functionalized porcine gastric and bovine submaxillary mucins with -lipoic acid to develop a single-component, photo-crosslinkable hydrogels. Upon UV irradiation (365 nm), the modified mucins rapidly form disulfide-crosslinked networks without added photo-initiator/ polymeric crosslinkers, two orders of magnitude faster as compared with PEG-SH approaches. The resulting mucin-lipoic acid (MUC-LA) hydrogels exhibit mucus-relevant properties, including tunable viscoelasticity, redox responsiveness, self-healing, and size-dependent restrictions on nanoparticle transport. In transwell-based infection models, MUC-LA hydrogels (2-3%) mimicking the healthy airway mucus (G' {approx} 10-20 Pa) suppress epithelial infection by SARS-CoV-2 and influenza A virus. Crosslinked MUC-LA provides greater protection against SARS-CoV-2 than the non-crosslinked, whereas both formulations suppress influenza A infection, suggesting distinct contributions from network formation and mucin-associated interactions. These findings establish a dynamic, mucus-mimetic platform integrating rapid photo-gelation, controllable mechanics, selective transport, and antiviral barrier functionality. MUC-LA hydrogels offer opportunities to investigate mucosal transport and host-pathogen interactions, with potential applications in drug delivery, and as biomaterials.

bioengineering↗

A Fibrous Optofluidic Probe for Endovascular Sensing of Blood Oxygenation and Flow Velocity

Local hemodynamic information including blood oxygenation and flow velocity could guide vascular interventions, yet obtaining these parameters in deep, narrow vessels remains challenging. Here, we report a flexible, submillimeter-scale fibrous optofluidic probe for endovascular sensing of blood oxygenation and flow velocity. The probe integrates a polymer optical fiber for light transmission with a microfluidic tube for dye injection, enabling spectroscopic oximetry and fluorescence dilution-based velocimetry through a single device. Via vascular intervention, we demonstrate local hemodynamic sensing in rabbit arteries and angiography-guided deployment in canine carotid arteries. The probe captures local changes in blood oxygenation and flow velocity during vascular occlusion and reperfusion, revealing hemodynamic disturbances that are not reflected in peripheral monitors. These results illustrate the complementary information provided by local oximetry and velocimetry and establish a compact optofluidic platform for quantitative hemodynamic monitoring during vascular interventions.

bioengineering↗

Broad-spectrum in situ genetic reprogramming of native microbiomes

Complex microbial communities are found throughout terrestrial, aquatic, and animal-associated ecosystems. Genetic modification of discrete microbial taxa within native communities represents a powerful tool to study and augment microbiome functions. Herein, we develop Synthetic Phage Assisted Reprogrammable and Targetable Addition (SPARTA) as a one-step strategy for packaging, delivering, and integrating large synthetic DNA into a broad range of native microbiomes. SPARTA leverages a broad-spectrum synthetic phage particle for in situ genome engineering within complex soil, freshwater, and mammalian fecal microbiomes, reprogramming 59 native species across 16 families. By modulating SPARTA components, we further demonstrated tunability of SPARTA towards targeted microbiome population. Additionally, we built a novel companion tool to quantitatively identify engineered taxa, named 16S crRNA-guided inference of bacterial engineering sequencing or ScRibe-seq. The SPARTA-ScRibe-seq pipeline delivered and validated functional synthetic gene clusters in diverse native microbiomes while preserving the original microbial community structure. Together, this novel genome engineering framework constitutes an end-to-end programmable platform for rational and customizable reprogramming of native microbiomes.

bioengineering↗