Abstract

Cochlear implants (CIs) have restored enough of a sense of hearing to around one million severely hearing impaired patients to enable speech understanding in quiet. However, several aspects of hearing with CIs remain very poor. This includes a severely limited ability of CI patients to make use of interaural time difference (ITD) cues for spatial hearing and noise reduction. A major cause for this poor ITD sensitivity could be that current clinical devices fail to deliver ITD information in a manner that is accessible to the auditory pathway. CI processors measure the envelopes of incoming sounds and then stimulate the auditory nerve with electrical pulse trains which are amplitude modulated to reflect incoming sound envelopes. The timing of the pulses generated by the devices is largely or entirely independent of the incoming sounds. Consequently, bilateral CIs (biCIs) provide veridical envelope (ENV) ITDs but largely or entirely replace the "fine structure" ITDs that naturally occur in sounds with completely arbitrary electrical pulse timing (PT) ITDs. To assess the extent to which this matters, we devised experiments that measured the sensitivity of deafened rats to precisely and independently controlled PT and ENV ITDs for a variety of different CI pulse rates and envelope shapes. We observed that PT ITDs completely dominate ITD perception, while the sensitivity to ENV ITDs was almost negligible in comparison. This strongly suggests that the confusing yet powerful PT ITDs that contemporary clinical devices deliver to biCI patients may be a major cause of poor binaural hearing outcomes with biCIs. Significance StatementCIs deliver spectro-temporal envelopes, including speech formants, to severely deaf patients, but they do little to cater to the brains ability to process temporal sound features with sub-millisecond precision. CIs "sample" sound envelope signals rapidly and accurately, and thus provide information which should make it possible in principle for CI listeners to detect envelope ITDs in a similar way to normal listeners. However, here we demonstrate through behavioral experiments on CI implanted rats trained to detect sub-millisecond ITDs that pulse timing ITDs completely dominate binaural hearing. This provides the strongest confirmation to date that the arbitrary pulse timing widely used in current clinical CIs is a critical obstacle to good binaural hearing through prosthetic devices.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Schnupp, J. W., Buchholz, S., Buck, A. N., Budig, H. K., Khurana, L., Rosskothen-Kuhl, N.. 2023-08-04. Is Inappropriate Pulse Timing Responsible for Poor Binaural Hearing with Cochlear Implants?. https://doi.org/10.1101/2023.08.04.551983

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

CoReg, tracking-based motion compensation for in vivo calcium imaging

In vivo calcium imaging enables the observation of neural activity with high spatial and temporal resolution. However, recordings are frequently affected by motion artifacts caused by animal movement, physiological processes, tissue drift, or instability of the imaging setup. These artifacts make signal extraction harder and reduce the consistency of downstream analyses. Current registration methods can correct rigid and non-rigid motion, but often estimate motion from individual frames or image patches and make limited use of temporal information. In addition, activity-driven fluorescence changes can make it difficult to distinguish changes in image appearance from actual motion. Here, we treat motion correction in calcium imaging as a point tracking problem and introduce CoReg, an open-source Python- based software tool with a graphical user interface. We benchmark CoReg against established registration methods using fluorescence imaging datasets from multiple species. CoReg performs competitively with or better than existing approaches across several settings. We further show that its performance is robust to the choice of tracked points, making the method straightforward to apply. CoReg includes implementations of both our method and the evaluated established methods. Our results show that tracking-based registration provides a simple and reliable approach for motion correction in vivo calcium imaging.

neuroscience↗

A shared slowing axis and phenotype-specific rhythms link clinical EEG to FDG-PET dementia phenotypes

Early and accurate identification of neurodegenerative disorders has notable implications for treatment and quality of life. Whereas neuroimaging-based biomarkers can accurately identify neurodegenerative subtypes, EEG represents a low-cost alternative that could expand access to dementia care. Here, we investigated whether six data-driven EEG latent factors, derived by nonnegative tensor decomposition of clinical EEGs, differ systematically across FDG-PET-defined neurodegenerative phenotypes. In 455 patients with EEG and FDG-PET acquired within one year of each other, factor expression was compared across 14 diagnostic classes assigned by StateViewer, a validated artificial intelligence framework for FDG-PET interpretation. To separate disease-general severity from phenotype-specific topography, each factor was also regressed on a subject-level slowing index. Finally, we related the factors to regional FDG uptake and to neuropsychological performance (n = 98) and assessed their potential utility for single-subject classification. Four factors reflecting neurophysiological oscillations (posterior alpha, Rolandic beta, frontotemporal delta-theta and posterior theta-slow alpha) varied significantly across phenotypes, with attenuation of faster and augmentation of slower rhythms most pronounced in dementia with Lewy bodies (DLB), dysexecutive Alzheimer disease (AD) and posterior cortical atrophy, whereas factors dominated by eye-movement and muscle artifact showed no robust phenotypic association. Alpha and beta effects were largely attributable to overall slowing, whereas posterior theta-slow alpha became more phenotype-specific after adjustment (eta-squared 0.082 to 0.147), dissociating the Alzheimer disease spectrum from frontotemporal syndromes. The slowing index tracked with an FDG-PET pattern highly associated with DLB across the cohort, irrespective of assigned phenotype (r = 0.51, P < 0.001). Consistent with a model in which dementia phenotypes reflect altered hippocampal-neocortical oscillatory coupling (stochastic latent oscillatory diffusion), frontotemporal delta-theta tracked a limbocortical axis of metabolic pattern expression, rising with neocortical and falling with limbic-predominant involvement, independent of overall slowing and phenotype. Each factor mapped onto a distinct metabolic topography, with frontotemporal delta-theta resembling Alzheimer-type hypometabolism and posterior theta-slow alpha the medial occipital hypometabolism of DLB. In terms of neuropsychological performance, Rolandic beta was associated with executive functions, and frontotemporal delta-theta with memory, visuospatial and global performance. Using these four factors alone, an exploratory logistic regression classifier separated cognitively unimpaired participants from DLB, posterior cortical atrophy, typical AD, and dysexecutive AD (area under the curve > 0.8) but poorly discriminated frontotemporal dementia phenotypes canonically associated with 4-repeat tau. Thus, data-driven decomposition of clinical EEG separates oscillatory activity from artifact into factors that track metabolic phenotype, regional metabolism and cognition, capturing both overall slowing and phenotype-specific patterns. This work informs the further development of scalable, biology-informed EEG-based phenotyping of neurodegenerative disease.

neuroscience↗

An application of fNIRS for the prediction of hearing thresholds in sleeping infants: a proof of principle

This study applied a two-component-response modelling approach to fNIRS recordings obtained from naturally sleeping infants presented with auditory stimuli at different sound intensities. We investigated whether the relationship between fNIRS response measures and stimulus intensity could be modelled to estimate individual auditory hearing thresholds. In the normal-hearing group, 75% of infants had threshold estimates for the sound /ba/ within the expected normal-hearing range, with an estimated mean equivalent normal loudness (ENL) of 10.72 dB HL (SD 8.64 dB HL). A case study further explored the potential application of this approach in an infant with hearing impairment, highlighting the importance of reliable responses at lower stimulus intensities and appropriate regression model selection. These findings provide preliminary evidence that cortical haemodynamic responses can be quantitatively related to sound intensity for estimating auditory sensitivity.

neuroscience↗