Neurophysiological Sensitivity to Envelope and Pulse Timing Interaural Time Differences in Cochlear Implanted Rats with Different Hearing Experiences

Cochlear implants (CIs) have successfully restored hearing in more than one million patients with severe to profound hearing loss worldwide. While CIs effectively restore speech perception in quiet environments, sound localization remains challenging for bilateral CI users, particularly their ability to utilize interaural time differences (ITDs). The majority of clinical CI processors use a coding strategy that encodes ITD information only in the envelope of electrical pulse trains rather than their pulse timing, which may contribute to the poorer spatial hearing perception of CI users. We recently demonstrated in a behavioral study on early deafened, bilaterally CI-implanted rats that pulse timing ITDs completely dominate ITD perception, while sensitivity to envelope ITDs is almost negligible in comparison. Building on this, we here investigated the neurophysiological sensitivity of the inferior colliculus (IC) to envelope and pulse timing ITDs at two different pulse rates (900 and 4500 pulses/s) and three different stimulation modulations (5, 20 and 100 Hz) in CI rats with different hearing experiences. Our results indicate that IC neurons exhibit far greater sensitivity to pulse timing ITD than envelope ITD independent of pulse rate, modulation rate or hearing experience. These findings suggest that to improve binaural hearing outcome in bilateral CI users, clinical stimulation strategies should provide informative pulse timing ITDs. Graphical abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=131 SRC="FIGDIR/small/675523v1_ufig1.gif" ALT="Figure 1"> View larger version (44K): org.highwire.dtl.DTLVardef@1874d3borg.highwire.dtl.DTLVardef@1df79feorg.highwire.dtl.DTLVardef@c244e5org.highwire.dtl.DTLVardef@39220f_HPS_FORMAT_FIGEXP M_FIG C_FIG

neuroscience↗

Interactions of Interaural Time and Level Differences in Spatial Hearing with Cochlear Implants

Normally hearing humans can localize sound sources quite accurately, with minimum audible angles as small as 1{degrees}. To achieve this, our auditory pathways combine information from multiple acoustic cues, including interaural time and interaural level differences (ITDs and ILDs). Patients relying on cochlear implants (CIs) to hear the world cannot match normal performance. These deficits are most pronounced in patients with little or no hearing experience early in life, and they appear to result from an impaired sensitivity to ITDs, but not to ILDs. However, little is known about how ITD and ILD sensitivities develop and interact in an early deafened auditory system shortly after CI implantation. We fitted neonatally deafened rats with bilateral CIs, and, providing informative ITDs and ILDs from stimulation onset, trained them to lateralize CI stimuli. These animals were exquisitely sensitive to both ILDs and ITDs of CI stimulus pulses, and combined information from both cues in a weighted sum. Importantly, ITDs are weighted heavily in our CI rats, such that only very modest ITDs pointing in one direction can confound quite large ILDs pointing in the opposite direction. This underlines the importance of informative ITDs for maximizing the potential for spatial hearing with CI devices. O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=181 SRC="FIGDIR/small/635454v1_ufig1.gif" ALT="Figure 1"> View larger version (36K): org.highwire.dtl.DTLVardef@15ee6e2org.highwire.dtl.DTLVardef@1881bd4org.highwire.dtl.DTLVardef@db17c7org.highwire.dtl.DTLVardef@1f62f2f_HPS_FORMAT_FIGEXP M_FIG C_FIG

neuroscience↗

Interaural level difference sensitivity in neonatally deafened rats fitted with bilateral cochlear implants

Bilateral cochlear implant (CI) patients exhibit significant limitations in spatial hearing. Their ability to process interaural time differences (ITDs) is often impaired, while their ability to process interaural level differences (ILDs) remains comparatively good. Clinical studies aiming to identify the causes of these limitations are often plagued by confounds and ethical limitations. Recent behavioral work suggests that rats may be a good animal model for studying binaural hearing under neuroprosthetic stimulation, as rats develop excellent ITD sensitivity when provided with suitable CI stimulation. However, their ability to use ILDs has not yet been characterized. Objective of this study is to address this knowledge gap. Neontally deafened rats were bilaterally fitted with CIs, and trained to lateralize binaural stimuli according to ILD. Their behavioral ILD thresholds were measured at pulse rates from 50 to 2400 pps. CI rats exhibited high sensitivity to ILDs with thresholds of a few dB at all tested pulse rates. We conclude that early deafened rats develop good sensitivity, not only to ITDs but also to ILDs, if provided with appropriate CI stimulation. Their generally good performance, in line with expectations from other mammalian species, validates rats as an excellent model for research on binaural auditory prostheses.

neuroscience↗

Does age protect against loss of tonotopy after acute deafness in adulthood?

The mammalian auditory system develops a topographical organization of sound frequencies along its pathways, also called tonotopy, as a result of early auditory input. In contrast, sensory deprivation during early development results in no or only rudimentary tonotopic organization. This study addresses two questions: 1) How robust is the tonotopy when hearing fails in adulthood? 2) What role does age play at time of deafness? To address these questions, we deafened young and old adult rats with normal hearing. One month after deafness, both groups were unilaterally supplied with cochlear implants and electrically stimulated for two hours. The central auditory neurons, which were activated as a result of the local electrical intracochlear stimulation, were visualized using Fos staining. While the auditory system of young rats lost the tonotopic organization throughout the brainstem, the auditory system of the older rats mainly sustained its tonotopy. It can be proposed that neuronal plasticity prevails in the central auditory system of young adult rats, while neuronal stability prevails in the brains of aging rats. Consequently, age may be an important factor in protecting a hearing-experienced adult auditory system from a rapid loss of tonotopy when suffering from acute hearing loss. Furthermore, the study provides compelling evidence that acute deafness in young adult patients should be diagnosed as early as possible to prevent maladaptation of the central auditory system and thus achieve the optimal hearing outcome with a hearing prosthesis.

neuroscience↗

Is Inappropriate Pulse Timing Responsible for Poor Binaural Hearing with Cochlear Implants?

Cochlear implants (CIs) have restored enough of a sense of hearing to around one million severely hearing impaired patients to enable speech understanding in quiet. However, several aspects of hearing with CIs remain very poor. This includes a severely limited ability of CI patients to make use of interaural time difference (ITD) cues for spatial hearing and noise reduction. A major cause for this poor ITD sensitivity could be that current clinical devices fail to deliver ITD information in a manner that is accessible to the auditory pathway. CI processors measure the envelopes of incoming sounds and then stimulate the auditory nerve with electrical pulse trains which are amplitude modulated to reflect incoming sound envelopes. The timing of the pulses generated by the devices is largely or entirely independent of the incoming sounds. Consequently, bilateral CIs (biCIs) provide veridical envelope (ENV) ITDs but largely or entirely replace the "fine structure" ITDs that naturally occur in sounds with completely arbitrary electrical pulse timing (PT) ITDs. To assess the extent to which this matters, we devised experiments that measured the sensitivity of deafened rats to precisely and independently controlled PT and ENV ITDs for a variety of different CI pulse rates and envelope shapes. We observed that PT ITDs completely dominate ITD perception, while the sensitivity to ENV ITDs was almost negligible in comparison. This strongly suggests that the confusing yet powerful PT ITDs that contemporary clinical devices deliver to biCI patients may be a major cause of poor binaural hearing outcomes with biCIs. Significance StatementCIs deliver spectro-temporal envelopes, including speech formants, to severely deaf patients, but they do little to cater to the brains ability to process temporal sound features with sub-millisecond precision. CIs "sample" sound envelope signals rapidly and accurately, and thus provide information which should make it possible in principle for CI listeners to detect envelope ITDs in a similar way to normal listeners. However, here we demonstrate through behavioral experiments on CI implanted rats trained to detect sub-millisecond ITDs that pulse timing ITDs completely dominate binaural hearing. This provides the strongest confirmation to date that the arbitrary pulse timing widely used in current clinical CIs is a critical obstacle to good binaural hearing through prosthetic devices.

neuroscience↗

Interaural time difference sensitivity under binaural cochlear implant stimulation even at high pulse rates up to 900 pps

BackgroundSpatial hearing remains one of the major challenges for bilateral cochlear implant (biCI) users, and early deaf patients in particular are often completely insensitive to interaural time differences (ITDs) delivered through biCIs. One popular hypothesis is that this may be due to a lack of early binaural experience. However, we have recently shown that neonatally deafened rats fitted with biCIs in adulthood quickly learn to discriminate ITDs as well as their normal hearing litter mates, and perform an order of magnitude better than human biCI users. MethodsOur unique behaving biCI rat model allows us to investigate other possible limiting factors of prosthetic binaural hearing, such as the effect of stimulus pulse rate and envelope shape. Previous work has indicated that ITD sensitivity may decline substantially at the high pulse rates often used in clinical practice. We therefore measured behavioral ITD thresholds in neonatally deafened, adult implanted biCI rats to pulse trains of 50, 300, 900 and 1800 pulses per second (pps), with either rectangular or Hanning window envelopes. ResultsOur rats exhibited very high sensitivity to ITDs at pulse rates up to 900 pps for both envelope shapes, similar to those in common clinical use. However, ITD sensitivity declined to near zero at 1800 pps, for both Hanning and rectangular windowed pulse trains. ConclusionsCurrent clinical cochlear implant (CI) processors are often set to pulse rates [≥]900 pps, but ITD sensitivity in human CI listeners has been reported to decline sharply above [~]300 pps. Our results suggest that the relatively poor ITD sensitivity seen at >300 pps in human CI users may not reflect the hard upper limit of biCI ITD performance in the mammalian auditory pathway. Perhaps with training or better CI strategies good binaural hearing may be achievable at pulse rates high enough to allow good sampling of speech envelopes while delivering usable ITDs.

neuroscience↗

Diversify your workflow! - An inconvenient suggestion to analyze spike data from intracranial recordings

An important challenge of neuroscience research and future brain machine interfacing is the reliable assignment of spikes to putative neurons. By means of extracellular recordings, researchers try to match different types action potentials with their putative neuronal source and timing. Unfortunately, this procedure is by far not standardized and reliable, leading to many different suggestions and as many differing results. It appears that sharing of data is thus hampered by different processing pipelines in different labs, thus playing along the reproducibility crisis in neurosciences. To systematically shed light on this issue, we present preliminary results of several easy event detection schemes on one data set, meant to illustrate the inconsistencies arising from different processing pipelines already in its initial step. The results indicate that thresholding choices alter findings due to a lack of a ground truth for spike sorting. We suggest to increase reliability in findings by only accepting and further processing events accepted by more than one processing pipeline.

neuroscience↗

Optimal Multichannel Artifact Prediction and Removal for Brain Machine Interfaces and Neural Prosthetics

Neural implants that electrically stimulate neural tissue such as deep brain stimulators, cochlear implants (CI), and vagal nerve stimulators are becoming the routine treatment options for various diseases. Optimizing electrical stimulation paradigms requires closed-loop stimulation using simultaneous recordings of evoked neural activity in real time. Stimulus-evoked artifacts at the recording site are generally orders of magnitude larger than the neural signals, which challenge the interpretation of evoked neural activity. We developed a generalized artifact removal algorithm that can be applied in a variety of neural recording modalities. The procedure leverages known electrical stimulation currents to derive optimal filters that are used to predict and remove artifacts. We validated the procedure using paired recordings and electrical stimulation from sciatic nerve axons, high-rate bilateral CI stimulation, and concurrent multichannel stimulation in auditory midbrain and recordings in auditory cortex. We demonstrate a vast enhancement in the quality of recording even for high-throughput multi-site stimulation with typical improvements in the signal-to-noise ratio between 20-40 dB. The algorithm is efficient, can be scaled to arbitrary number of sites, and is applicable in range of recording modalities. It has numerous benefits over existing approaches and thus should be valuable for emerging neural recording and stimulation technologies.

neuroscience↗

Microsecond Interaural Time Difference Discrimination Restored by Cochlear Implants After Neonatal Deafness

Cochlear implants (CIs) can restore a high degree of functional hearing in deaf patients however spatial hearing remains poor, with many early deaf CI users reported to have no measurable sensitivity to interaural time differences (ITDs) at all. Deprivation of binaural experience during an early critical period is often blamed for this shortcoming. However, we show that neonatally deafened rats provided with precisely synchronized CI stimulation in adulthood can be trained to localize ITDs with essentially normal behavioral thresholds near 50 s. Furthermore, neonatally deaf rats show high physiological sensitivity to ITDs immediately after binaural implantation in adulthood. The fact that our neonatally deaf CI rats achieved very good behavioral ITD thresholds while prelingually deaf human CI patients usually fail to develop a useful sensitivity to ITD raises urgent questions about whether shortcomings in technology or treatment may be behind the usually poor binaural outcomes for current binaural CI patients.

neuroscience↗