bioRxiv Science⌕ Search

bioRxiv · 10.1101/2022.03.20.485063

Multiple forward scattering reduces the measured scattering coefficient of whole blood in visible-light optical coherence tomography

Abstract

Optical properties of blood encode oxygen-dependent information. Noninvasive optical detection of these properties is increasingly desirable to extract biomarkers for tissue health. Recently, visible-light optical coherence tomography (vis-OCT) demonstrated retinal oxygen saturation (sO2) measurements using the depth-resolved spectrum of blood. Such measurements rely on differences between the absorption and scattering coefficients of oxygenated and deoxygenated blood. However, there is still broad disagreement, both theoretically and experimentally, on how vis-OCT measures bloods scattering coefficient. Incorrect assumptions of bloods optical properties can add additional uncertainties or biases into vis-OCTs sO2 model. Using Monte Carlo simulation of a retinal vessel, we determined that vis-OCT almost exclusively detects multiple-scattered photons in blood. Meanwhile, photons mostly forward scatter in blood within the visible spectral range, allowing photons to maintain ballistic paths and penetrate deeply, leading to a reduction in the measured scattering coefficient. We defined a scattering scaling factor (SSF) to account for such a reduction and found that SSF varied with measurement conditions, such as numerical aperture, depth resolution, and depth selection. We further experimentally validated SSF in ex vivo blood phantoms pre-set sO2 levels and in the human retina, both of which agreed well with our simulation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fang, R., Rubinoff, I., Zhang, H. F.. 2022-03-21. Multiple forward scattering reduces the measured scattering coefficient of whole blood in visible-light optical coherence tomography. https://doi.org/10.1101/2022.03.20.485063

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Single-Component Photo-Crosslinked Lipoic Acid Functionalized Mucin Hydrogels: Dynamic Mucus Mimetics for Antiviral Protection

Native mucus protects epithelial surfaces through viscoelastic networks of disulfide-linked mucins. However, commercially available mucins often fail to reconstitute comparable mechanical and barrier properties, while synthetic and hybrid mucus mimetics require polymeric crosslinkers that may alter mucus-like composition. Inspired by the native architecture, we directly functionalized porcine gastric and bovine submaxillary mucins with -lipoic acid to develop a single-component, photo-crosslinkable hydrogels. Upon UV irradiation (365 nm), the modified mucins rapidly form disulfide-crosslinked networks without added photo-initiator/ polymeric crosslinkers, two orders of magnitude faster as compared with PEG-SH approaches. The resulting mucin-lipoic acid (MUC-LA) hydrogels exhibit mucus-relevant properties, including tunable viscoelasticity, redox responsiveness, self-healing, and size-dependent restrictions on nanoparticle transport. In transwell-based infection models, MUC-LA hydrogels (2-3%) mimicking the healthy airway mucus (G' {approx} 10-20 Pa) suppress epithelial infection by SARS-CoV-2 and influenza A virus. Crosslinked MUC-LA provides greater protection against SARS-CoV-2 than the non-crosslinked, whereas both formulations suppress influenza A infection, suggesting distinct contributions from network formation and mucin-associated interactions. These findings establish a dynamic, mucus-mimetic platform integrating rapid photo-gelation, controllable mechanics, selective transport, and antiviral barrier functionality. MUC-LA hydrogels offer opportunities to investigate mucosal transport and host-pathogen interactions, with potential applications in drug delivery, and as biomaterials.

bioengineering↗

A Fibrous Optofluidic Probe for Endovascular Sensing of Blood Oxygenation and Flow Velocity

Local hemodynamic information including blood oxygenation and flow velocity could guide vascular interventions, yet obtaining these parameters in deep, narrow vessels remains challenging. Here, we report a flexible, submillimeter-scale fibrous optofluidic probe for endovascular sensing of blood oxygenation and flow velocity. The probe integrates a polymer optical fiber for light transmission with a microfluidic tube for dye injection, enabling spectroscopic oximetry and fluorescence dilution-based velocimetry through a single device. Via vascular intervention, we demonstrate local hemodynamic sensing in rabbit arteries and angiography-guided deployment in canine carotid arteries. The probe captures local changes in blood oxygenation and flow velocity during vascular occlusion and reperfusion, revealing hemodynamic disturbances that are not reflected in peripheral monitors. These results illustrate the complementary information provided by local oximetry and velocimetry and establish a compact optofluidic platform for quantitative hemodynamic monitoring during vascular interventions.

bioengineering↗

Broad-spectrum in situ genetic reprogramming of native microbiomes

Complex microbial communities are found throughout terrestrial, aquatic, and animal-associated ecosystems. Genetic modification of discrete microbial taxa within native communities represents a powerful tool to study and augment microbiome functions. Herein, we develop Synthetic Phage Assisted Reprogrammable and Targetable Addition (SPARTA) as a one-step strategy for packaging, delivering, and integrating large synthetic DNA into a broad range of native microbiomes. SPARTA leverages a broad-spectrum synthetic phage particle for in situ genome engineering within complex soil, freshwater, and mammalian fecal microbiomes, reprogramming 59 native species across 16 families. By modulating SPARTA components, we further demonstrated tunability of SPARTA towards targeted microbiome population. Additionally, we built a novel companion tool to quantitatively identify engineered taxa, named 16S crRNA-guided inference of bacterial engineering sequencing or ScRibe-seq. The SPARTA-ScRibe-seq pipeline delivered and validated functional synthetic gene clusters in diverse native microbiomes while preserving the original microbial community structure. Together, this novel genome engineering framework constitutes an end-to-end programmable platform for rational and customizable reprogramming of native microbiomes.

bioengineering↗