Zhang, H. F.

Publications and source records attributed to Zhang, H. F..

At least 19 recordsLinked to original sources

Imaging biological tissue at extended depth using swept-source visible-light OCT

We present a swept-source visible-light optical coherence tomography (SS-vis-OCT) system with twice the imaging depth of prior SS-vis-OCT and improved sensitivity for imaging biological samples, achieving shot-noise-limited operation. Because second-harmonic generation is limited by the booster optical amplifier's output power, the visible-light SS power is capped at 450 W. Increasing it further would require a more powerful, but costlier, amplifier. Instead, we reduce the receiver noise floor by selecting a balanced detector with NEP approaching the thermal (Johnson-Nyquist) limit. Real-time numerical k-linearization increases the effective number of linear-in-wavenumber samples per sweep, further improving SNR and extending the imaging range. Together, these improvements yield a sensitivity of 89 dB and an imaging depth of 9 mm in air or 6.5 mm in tissue, enabling full anterior-segment imaging of ex vivo porcine eyes.

bioengineering↗

Closed-loop optical optimization enables patterned retinal stimulation in vivo at cellular scales

Visual neuroscience requires precise spatiotemporal projection of optical stimulation onto the retina, especially in experimental mouse models. However, in vivo patterned stimulation in mice is profoundly hindered by the extreme optical power and severe anatomical aberrations of the eye. Consequently, visual stimulation relies mainly on unverifiable, open-loop approximations that often lack spatial precision. Here, we introduce a closed-loop, spatially modulated stimulation platform that overcomes these barriers. By integrating a digital micromirror device (DMD) with electronically tunable lenses (ETLs) and a real-time, fundus camera-guided focus optimization module, we directly verify the location of patterned stimuli on the retina while dynamically correcting for chromatic and geometric defocus. This platform delivers quantitatively verified static and dynamic patterned stimuli to the living retina with lateral resolutions as fine as 6.7 {micro}m. Guided by ray-tracing optical analysis, our work establishes a technological foundation that enables highly reproducible, cellular-scale interrogations of the visual pathway.

bioengineering↗

Balancing performance and complexity of dual-wedge prism-based spectroscopic single-molecule localization microscopy

Spectroscopic single-molecule localization microscopy (sSMLM) enables multiplexed super-resolution imaging by simultaneously acquiring the spatial position and spectral information of individual fluorophores. Dual-wedge prism (DWP)-based implementations provide a compact, alignment-stable approach to spectral dispersion, but trade-offs between localization precision, spectral precision, and experimental complexity remain. We systematically compare five DWP-based sSMLM configurations, including two-dimensional (2D) and three-dimensional (3D) implementations using single DWP (DWP-sSMLM) and symmetrically-dispersed DWP (SDDWP-sSMLM). We evaluate lateral precision, spectral precision, and ease of use. SDDWP configurations acquire spectral images in both channels and utilize both for spatial localization, yielding the highest lateral and spectral precision. However, for applications that do not require axial information, 2D-DWP provides a simple, plug-and-play solution with robust performance. This work offers a guideline for selecting DWP configurations based on experimental needs.

bioengineering↗

The dynamics of nucleolus-centromeres interaction in living cells

Nucleoli and centromeres play essential roles in cellular proliferation and homeostasis, and are structurally and functionally interconnected. Centromeres frequently cluster around nucleoli, and some centromere assembly factors are known to reside in the nucleoli. To investigate the spatial and temporal relationships between these nuclear domains, we examined their dynamics in living cells. We imaged HeLa cells stably expressing mCherry-NPM1 and GFP-CENP-A using time-lapse microscopy. The results show that a subset of centromeres exhibits dynamic behavior during interphase, migrating over micrometer-scale distances within two hours. On average, 40-50% of centromeres maintain an association with nucleoli throughout interphase, with some cells displaying nucleolar-centromere association and dissociation within hours. Upon entry into mitosis, nucleoli are disassembled, and NPM1 localizes to the periphery of mitotic chromosomes. Nucleolar-centromere interactions are re-established in early G1, coinciding with the assembly of new centromeres. Treatment with actinomycin D, an inhibitor of RNA polymerase I, significantly reduces nucleolar size, nucleolar-centromere interactions, and centromere dynamics. Furthermore, post-mitotic nucleolar reformation is impaired. These findings highlight the dynamic nature of centromeres in interphase nuclei and their interactions with nucleoli. This behavior is partially dependent on rDNA transcription and nucleolar integrity, underscoring the critical roles of nucleoli, centromeres, and their interaction in 4D genome organization.

cell biology↗

Volumetric montaging of optical coherence tomography in human retinas

Optical coherence tomography (OCT) has transformed clinical eye care by providing high-resolution volumetric imaging of the retina. Recently, ultrawide-field-of-view (FOV) OCT played an increasingly significant clinical role; however, most clinical OCT systems offer only a rather limited FOV. We increased the FOV of clinical OCT by volumetrically montaging multiple OCT datasets in three dimensions (3D). We performed volumetric montaging by representing the internal limiting membrane (ILM) and retinal pigment epithelium (RPE) in each volume as point clouds and using these point clouds to compute transformations that map each volume to a common reference frame. We validated our methodology using datasets from three institutions with different OCT hardware and data-acquisition procedures. Using the mean surface distance between point clouds, we found the error in montaging was less than the lateral pixel size. Our method enabled existing clinical OCT to achieve ultrawide FOV imaging without any hardware modification.

bioengineering↗

Vitreous Inflammation as an Early Indicator of Retinal Ganglion Cell Loss Following Acute Optic Nerve Injury in Mice

Retinal ganglion cell (RGC) degeneration in optic neuropathies is often preceded by neuroinflammatory changes, yet the earliest in vivo indicators of this process remain poorly defined. Here, we identified vitreous hyperreflective foci (VHRFs) by visible-light optical coherence tomography (vis-OCT) as an early inflammatory signature of RGC injury. Longitudinal vis-OCT imaging after optic nerve crush (ONC) revealed that VHRFs emerged as early as 6 hours post-injury and peaked before the significant RGC loss. Confocal analysis showed that these VHRFs corresponded to activated amoeboid microglia undergoing vertical migration from the outer to inner retina and horizontal movement toward the optic nerve head area. Similar amoeboid microglia were also observed in the anterior segment, suggesting a global ocular inflammatory response to the ONC injury. RNAscope in situ hybridization further demonstrated elevated IL-1{beta} expression in vitreous amoeboid microglia. Moreover, pharmacological blockade of IL-1 signaling with an IL-1 receptor antagonist significantly reduced VHRFs, suppressed microglial migration, and delayed RGC loss. Taken together, our findings identify VHRFs as a previously unrecognized early danger signal for RGC degeneration and highlight IL-1-mediated inflammation as a tractable early therapeutic target for preventing RGC degeneration and vision loss. Graphical Overview O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=88 SRC="FIGDIR/small/694725v1_ufig1.gif" ALT="Figure 1"> View larger version (27K): org.highwire.dtl.DTLVardef@1598c4aorg.highwire.dtl.DTLVardef@9637borg.highwire.dtl.DTLVardef@623bf4org.highwire.dtl.DTLVardef@14e21ce_HPS_FORMAT_FIGEXP M_FIG C_FIG

neuroscience↗

PROX1 loss in adult mouse Schlemm's canal causes permanent ocular hypertension

Glaucoma is associated with ocular hypertension and lowering intraocular pressure is a key objective of glaucoma therapies. Recent studies have established a role for the Schlemms canal endothelium in this pressure increase and have shown it to have a unique, lymphatic-like, hybrid phenotype. However, the role of these lymphatic phenotypes in the adult canal remains uncertain. Long-term functional studies have been limited by systemic importance of lymphatic genes and lack of Schlemms canal-specific animal models. Here, we designed and validated a strategy using 4OH-tamoxifen-loaded nanocarriers to generate targeted, Schlemms canal specific knockout mice lacking lymphatic phenotypes. Using this system, we selectively deleted Prox1, the master transcription factor governing lymphatic fate. Within four weeks, intraocular pressure significantly increased, and ocular hypertension was maintained for at least 24 weeks. Unlike lymphatic vessels, which degenerate following Prox1 deletion, Schlemms canal reverted to a less functional vein-like phenotype with no change in size or morphology. These results highlight the utility of nanocarriers for tissue-specific genetic recombination and demonstrate that changes in lymphatic phenotypes alter intraocular pressure, providing new targets for glaucoma therapy. Moreover, as we found that PROX1 was downregulated with age in human Schlemms canal, these canal-specific conditional Prox1 knockout mice are a valuable new adult-onset model of ocular hypertension that captures key features of age-related human disease.

physiology↗

Vis-OCT Explorer: an open-source software for visible-light optical coherence tomography data processing

Background and objectivesVisible-light optical coherence tomography (vis-OCT) has enabled the visualization of retinal structures and functions beyond the capabilities of conventional OCTs. However, to reconstruct high-quality images, vis-OCT requires special post-processing, including balanced detection. An open-source, standardized vis-OCT data processing software is essential for clinical applications and translation of vis-OCT. MethodsWe developed Vis-OCT Explorer, an open-source, modular Python-based software for processing vis-OCT images. In addition to the standard spectral-domain OCT processing pipeline - including k-space resampling, dispersion compensation, and fast Fourier transformation - Vis-OCT Explorer offers unique dual-spectrometer balanced detection, short-time-Fourier transformation (STFT) based dispersion compensation coefficient optimization, and GPU-accelerated processing. We evaluated the reconstruction performance by quantifying a quality index extracted from individual B-scan images. We also assessed the repeatability of retinal thickness measurements by five operators on images acquired from different testing sites using the intraclass correlation coefficient (ICC) analysis. ResultsBalanced detection and STFT-based dispersion compensation significantly increased the quality index of reconstructed B-scan images. ICC values of the retinal nerve fiber layer (RNFL) and ganglion cell-inner plexiform layer (GCIPL) thickness measurements from four testing sites exceeded 0.8 in 87.5% of the macular-centered images. The ICC of RNFL thickness measurements on all optic nerve head-centered images is above 0.8, showing strong repeatability across users. ConclusionsVis-OCT Explorer provides high-quality image processing and enables highly repeatable measurements on vis-OCT human retinal images. It facilitates future multicenter clinical tests to validate vis-OCTs clinical efficacy.

bioengineering↗

Machine-learning-based automated Schlemms canal volumetric segmentation for optical coherence tomography

Volumetric segmentation of Schlemms Canal (SC) in optical coherence tomography (OCT) is time-consuming, creating a barrier to experiments studying glaucoma and the anatomy of the trabecular outflow pathways in vivo. To this end, we developed an automated segmentation tool, Schlemms Canal-Localization and Semantic Segmentation (SC-LSS), for the volumetric segmentation of SC in in vivo mice eyes from visible-light OCT (vis-OCT). SC-LSS first localizes the boundaries of SC and subsequently determines the boundaries of SC within the localized region. We used 324 B-scans from 16 mouse eyes for training, validation, and testing the model, and 203 additional B-scans from 16 mouse eyes to evaluate the models accuracy. We found that the Dice coefficient between segmentations generated by SC-LSS and manual expert graders was 0.70 {+/-} 0.20 and that the Dice coefficient between two expert graders was 0.73 {+/-} 0.18 (p = 0.10). Furthermore, SC-LSS captured decreases in SC size with increasing intraocular pressure, yielding a 51.5% decrease in SC size at 20 mmHg compared to 5 mmHg. SC-LSS also identified a 20.1% increase in SC size following the administration of pilocarpine. We anticipate that SC-LSS will accelerate studies on factors regulating the trabecular outflow pathways and their role in glaucoma development and management.

bioengineering↗

Robotic Visible-Light Optical Coherence Tomography Visualizes Segmental Schlemms Canal Anatomy and Segmental Pilocarpine Response

PurposeTo use robotic visible-light OCT (vis-OCT) to study circumferential segmental Schlemms canal (SC) anatomy in mice after topical pilocarpine administration. MethodsAnterior segment imaging was performed using a vis-OCT sample arm attached to a 6-degree-of-freedom robotic arm to maintain normal (perpendicular) laser illumination aimed at SC around the limbus. Sixteen mice were studied for repeatability testing and to study aqueous humor outflow (AHO) pathway response to topical drug. Pharmaceutical-grade pilocarpine (1%; n = 5) or control artificial tears (n = 9) were given, and vis-OCT imaging was performed before and 15 minutes after drug application. After SC segmentation, SC areas and volumes were measured circumferentially in control- and drug-treated eyes. ResultsCircumferential vis-OCT provided high-resolution imaging of the anterior segment and AHO pathways, including SC. Segmental SC anatomy was visualized with the average cross-sectional area greatest temporal (3971 {+/-} 328 {micro}m2) and the least nasal (2727 {+/-} 218 {micro}m2; p = 0.018). After pilocarpine administration, the iris became flatter, and SC became larger (pilocarpine: 26.8 {+/-} 5.0% vs. control: 8.9 {+/-} 4.6% volume increase; p = 0.030). However, the pilocarpine alteration was segmental as well, with a greater increase observed superior (pilocarpine: 31.6 {+/-} 8.9% vs. control: 1.8 {+/-} 5.7% volume increase; p = 0.023) and nasal (pilocarpine: 41.1 {+/-} 15.3% vs. control: 13.9 {+/-} 4.5% volume increase; p = 0.045). ConclusionHigh-resolution circumferential non-invasive imaging using AS-OCT of AHO pathways is possible in living animals with robotic control. Segmental SC anatomy was seen at baseline and was consistent with the known segmental nature of trabecular AHO. Segmental SC anatomical response to a muscarinic agonist was seen as well. Segmental glaucoma drug response around the circumference of AHO pathways is a novel observation that may explain the variable patient response to glaucoma treatments.

bioengineering↗

Implementation and calibration of spectroscopic single-molecule localization microscopy

Spectroscopic single-molecule localization microscopy (sSMLM) allows multi-color super-resolution images with high spectral sensitivity. In this protocol, we provide essential information for researchers to implement sSMLM in a laboratory setting. We describe how to assemble and align the illumination and detection paths of a 3D dual-wedge prism (DWP)-based sSMLM instrument. We provide detailed step-by-step instructions for performing spectral and axial calibration using fluorescent beads and a nanohole array, respectively. We also discuss using sSMLM to image fluorescently labeled cells and report a new MATLAB package, RainbowSTORM v2, to reconstruct super-resolution 3D images. Further, we present representative images as typical anticipated results for users to validate.

bioengineering↗

In vivo quantification of anterior and posterior chamber volumes in mice: implications for aqueous humor dynamics

PurposeAqueous humor inflow rate, a key parameter influencing aqueous humor dynamics, is typically measured by fluorophotometery. Analyzing fluorophotometric data depends, inter alia, on the volume of aqueous humor in the anterior, but not the posterior, chamber. Previous fluorophotometric studies of aqueous inflow rate in mice have assumed the ratio of anterior:posterior volumes in mice to be similar to those in humans. Our goal was to measure anterior and posterior chamber volumes in mice to facilitate better estimates of aqueous inflow rates. MethodsWe used standard near-infrared optical coherence tomography (OCT) and robotic visible-light OCT (vis-OCT) to visualize, reconstruct and quantify the volumes of the anterior and posterior chambers of the mouse eye in vivo. We used histology and micro-CT scans to validate relevant landmarks from ex vivo tissues to facilitate in vivo measurement. ResultsPosterior chamber volume is 1.1 times the anterior chamber volume in BALB/cAnNCrl mice, i.e. the anterior chamber constitutes about 47% of the total aqueous humor volume, which is very dissimilar to the situation in humans. Anterior chamber volumes in 2-month-old BALB/cAnNCrl and 7-month-old C57BL6/J mice were 1.55 {+/-} 0.36 {micro}L (n=10) and 2.41 {+/-} 0.29 {micro}L (n=8), respectively. This implies that previous studies likely over-estimated aqueous inflow rate by approximately two-fold. ConclusionsIt is necessary to reassess previously reported estimates of aqueous inflow rates, and thus aqueous humor dynamics in the mouse. For example, we now estimate that only 0-15% of aqueous humor drains via the pressure-independent (unconventional) route, similar to that seen in humans and monkeys.

physiology↗

Transport and Organization of Individual Vimentin Filaments Within Dense Networks Revealed by Single Particle Tracking and 3D FIB-SEM

Vimentin intermediate filaments (VIFs) form complex, tight-packed networks; due to this density, traditional ensemble labeling and imaging approaches cannot accurately discern single filament behavior. To address this, we introduce a sparse vimentin-SunTag labeling strategy to unambiguously visualize individual filament dynamics. This technique confirmed known long-range dynein and kinesin transport of peripheral VIFs and uncovered extensive bidirectional VIF motion within the perinuclear vimentin network, a region we had thought too densely bundled to permit such motility. To examine the nanoscale organization of perinuclear vimentin, we acquired high-resolution electron microscopy volumes of a vitreously frozen cell and reconstructed VIFs and microtubules within a [~]50 {micro}m3 window. Of 583 VIFs identified, most were integrated into long, semi-coherent bundles that fluctuated in width and filament packing density. Unexpectedly, VIFs displayed minimal local co-alignment with microtubules, save for sporadic cross-over sites that we predict facilitate cytoskeletal crosstalk. Overall, this work demonstrates single VIF dynamics and organization in the cellular milieu for the first time SummarySingle-particle tracking demonstrates that individual filaments in bundles of vimentin intermediate filaments are transported in the cytoplasm by motor proteins along microtubules. Furthermore, using 3D FIB-SEM the authors showed that vimentin filament bundles are loosely packed and co-aligned with microtubules.

cell biology↗

Freeform robotic optical coherence tomography beyond the optical field-of-view limit

Imaging complex, non-planar anatomies with optical coherence tomography (OCT) is limited by the optical field of view (FOV) in a single volumetric acquisition. Combining linear mechanical translation with OCT extends the FOV but suffers from inflexibility in imaging non-planar anatomies. We report the freeform robotic OCT to fill this gap. To address challenges in volumetric reconstruction associated with the robotic movement accuracy being two orders of magnitudes worse than OCT imaging resolution, we developed a volumetric registration algorithm based on simultaneous localization and mapping (SLAM) to overcome this limitation. We imaged the entire aqueous humor outflow pathway, whose imaging has the potential to customize glaucoma surgeries but is typically constrained by the FOV, circumferentially in mice as a test. We acquired volumetric OCT data at different robotic poses and reconstructed the entire anterior segment of the eye. The reconstructed volumes showed heterogeneous Schlemms canal (SC) morphology in the reconstructed anterior segment and revealed a segmental nature in the circumferential distribution of collector channels (CC) with spatial features as small as a few micrometers.

bioengineering↗

Maximizing photon utilization in spectroscopic single-molecule localization microscopy using symmetrically dispersed dual-wedge prisms

Single-molecule localization microscopy (SMLM) enables super-resolution imaging on conventional fluorescent microscopes. Spectroscopic SMLM (sSMLM) further allows highly multiplexed super-resolution imaging. We report an easy-to-implement symmetrically dispersed dual-wedge prism (SDDWP)-sSMLM design that maximizes photon utilization. We first symmetrically dispersed photons to the -1st and +1st orders in an optical assembly using two identical dual-wedge prisms (DWPs). Then we computationally extracted the fluorophores spatial position and spectral characteristics using photons in both the -1st and +1st orders. Theoretical analysis and experimental validation showed lateral and spectral precisions of 10.1 nm and 0.3 nm, respectively, representing improvements of 28% and 48% over our previous DWP-based system, where emitted photons are divided separately for spatial and spectral analyses.

bioengineering↗

Multiscale imaging of corneal endothelium damage and effects of Rho Kinase inhibitor application in mouse models of acute ocular hypertension

We developed a multiscale optical imaging workflow, integrating and correlating visible-light optical coherence tomography, confocal laser scanning microscopy, and single-molecule localization microscopy to investigate the mouse cornea damages from the in-vivo tissue level to the nanoscopic single-molecule level. We used electron microscopy to validate the imaged nanoscopic structures. We imaged wild-type mice and mice with acute ocular hypertension and examined the effects of Rho Kinase inhibitor application. We defined four types of intercellular tight junction structures as healthy, compact, partially-distorted, and fully-distorted types by labeling the Zonula occludens-1 protein in the corneal endothelial cell layer. We correlated the statistics of the four types of tight junction structures with cornea thickness and intraocular pressure. We found that the population of fully-distorted tight junctions correlated well with the level of cornea edema, and applying Rho Kinase inhibitor reduced the population of fully-distorted tight junctions under acute ocular hypertension.

biophysics↗

Physically informed Monte Carlo simulation of dual-wedge prism-based spectroscopic single-molecule localization microscopy

SignificanceThe dual-wedge prism (DWP)-based spectroscopic single-molecule localization microscopy (sSMLM) system offers improved localization precision and adjustable spectral or localization performance, but its nonlinear spectral dispersion presents a challenge. A systematic method can help understand the challenges and thereafter optimize the DWP systems performance by customizing system parameters to maximize spectral or localization performance for various molecular labels. AimWe developed an MC-based model which predicts the imaging output of the DWP-based sSMLM system given different system parameters. ApproachWe assessed our MC models localization and spectral precisions by comparing our simulation against theoretical equations and fluorescent microspheres. Furthermore, we simulated the DWP-based system using beamsplitters of Reflectance (R):Transmittance (T) of R50:T50 and R30:T70 and their tradeoffs. ResultsOur MC simulation showed average deviations of 2.5 nm and 2.1 nm for localization and spectral precisions against theoretical equations; and 2.3 nm and 1.0 nm against fluorescent microspheres. An R30:T70 beamsplitter improved spectral precision by 8% but worsened localization precision by 35% on average compared to an R50:T50 beamsplitter. ConclusionsThe MC model accurately predicted localization precision, spectral precision, spectral peaks, and spectral widths of fluorescent microspheres, as validated by experimental data. Our work enhances the theoretical understanding of DWP-based sSMLM for multiplexed imaging, enabling performance optimization.

bioengineering↗

Visible-Light Optical Coherence Tomography Fibergraphy of the Tree Shrew Retinal Ganglion Cell Axon Bundles

We seek to develop techniques for high-resolution imaging of the tree shrew retina for visualizing and parameterizing retinal ganglion cell (RGC) axon bundles in vivo. We applied visible-light optical coherence tomography fibergraphy (vis-OCTF) and temporal speckle averaging (TSA) to visualize individual RGC axon bundles in the tree shrew retina. For the first time, we quantified individual RGC bundle width, height, and cross-sectional area and applied vis-OCT angiography (vis-OCTA) to visualize the retinal microvasculature in tree shrews. Throughout the retina, as the distance from the optic nerve head (ONH) increased from 0.5 mm to 2.5 mm, bundle width increased by 30%, height decreased by 67%, and cross-sectional area decreased by 36%. We also showed that axon bundles become vertically elongated as they converge toward the ONH. Ex vivo confocal microscopy of retinal flat-mounts immunostained with Tuj1 confirmed our in vivo vis-OCTF findings.

bioengineering↗