bioRxiv Science⌕ Search

Biology subjects

Woodward, M.

Publications and source records attributed to Woodward, M..

3 recordsLinked to original sources

Modeling Thick Filament Activation Suggests a Molecular Basis for Force Depression

Multiscale models aiming to connect muscles molecular and cellular function have been difficult to develop, in part, due to a lack of self-consistent multiscale data. To address this gap, we measured the force response from single skinned rabbit psoas muscle fibers to ramp shortenings and step stretches performed on the plateau region of the force-length relationship. We isolated myosin from the same muscles and, under similar conditions, performed single molecule and ensemble measurements of myosins ATP-dependent interaction with actin using laser trapping and in vitro motility assays. We fit the fiber data by developing a partial differential equation model that includes thick filament activation, whereby an increase in force on the thick filament pulls myosin out of an inhibited state. The model also includes a series elastic element and a parallel elastic element. This parallel elastic element models a titin-actin interaction proposed to account for the increase in isometric force following stretch (residual force enhancement). By optimizing the model fit to a subset of our fiber measurements, we specified seven unknown parameters. The model then successfully predicted the remainder of our fiber measurements and also our molecular measurements from the laser trap and in vitro motility. The success of the model suggests that our multiscale data are self-consistent and can serve as a testbed for other multiscale models. Moreover, the model captures the decrease in isometric force observed in our muscle fibers after active shortening (force depression), suggesting a molecular mechanism for force depression, whereby a parallel elastic element combines with thick filament activation to decrease the number of cycling cross-bridges. SIGNIFICANCEConnecting the molecular and cellular scales of muscle contraction would assist in, e.g., the treatment of genetic muscle diseases, the development of heart drugs, and the design of prostheses. The history dependence of muscle contraction, having no clear molecular basis, has remained an obstacle in making this connection for the seventy years since its discovery. We measured the force- and motion-generating capacity of rabbit psoas muscle from the scale of single molecules to single cells. We developed a mathematical model that, when fit to some of the cellular measurements, predicted the remaining cellular measurements and also the molecular measurements. The models ability to capture muscles history dependence suggests a unified description of muscle contraction from the molecular to cellular scale.

biophysics↗

Positional isomers of a non-nucleoside substrate differentially affect myosin function

Molecular motors have evolved to transduce chemical energy from adenosine triphosphate into mechanical work to drive essential cellular processes, from muscle contraction to vesicular transport. Dysfunction of these motors is a root cause of many pathologies necessitating the need for intrinsic control over molecular motor function. Herein, we demonstrate that positional isomerism can be used as a simple and powerful tool to control the molecular motor of muscle, myosin. Using three isomers of a synthetic non-nucleoside triphosphate we demonstrate that myosins force and motion generating capacity can be dramatically altered at both the ensemble and single molecule levels. By correlating our experimental results with computation, we show that each isomer exerts intrinsic control by affecting distinct steps in myosins mechano-chemical cycle. Our studies demonstrate that subtle variations in the structure of an abiotic energy source can be used to control the force and motility of myosin without altering myosins structure. Statement of SignificanceMolecular motors transduce chemical energy from ATP into the mechanical work inside a cell, powering everything from muscle contraction to vesicular transport. While ATP is the preferred source of energy, there is growing interest in developing alternative sources of energy to gain control over molecular motors. We synthesized a series of synthetic compounds to serve as alternative energy sources for muscle myosin. Myosin was able to use this energy source to generate force and velocity. And by using different isomers of this compound we were able to modulate, and even inhibit, the activity of myosin. This suggests that changing the isomer of the substrate could provide a simple, yet powerful, approach to gain control over molecular motor function.

biophysics↗

A smartphone-based tool for rapid, portable, and automated wide-field retinal imaging

PurposeHigh-quality, wide-field retinal imaging is a valuable method to screen preventable, vision-threatening diseases of the retina. Smartphone-based retinal cameras hold promise for increasing access to retinal imaging, but variable image quality and restricted field of view can limit their utility. We developed and clinically tested a smartphone-based system that addresses these challenges with automation-assisted imaging.\n\nMethodsThe system was designed to improve smartphone retinal imaging by combining automated fixation guidance, photomontage, and multi-colored illumination with optimized optics, user-tested ergonomics, and touch-screen interface. System performance was evaluated from images of ophthalmic patients taken by non-ophthalmic personnel. Two masked ophthalmologists evaluated images for abnormalities and disease severity.\n\nResultsThe system automatically generated 100-degree retinal photomontages from five overlapping images in under 1 minute at full resolution (52.3 pixels per retinal degree) fully on-phone, revealing numerous retinal abnormalities. Feasibility of the system for DR screening using the retinal photomontages was performed in 71 diabetics by masked graders. DR grade matched perfectly with dilated clinical examination in 55.1% of eyes and within 1 severity level for 85.2% of eyes. For referral-warranted DR, average sensitivity was 93.3% and specificity 56.8%.\n\nConclusionsAutomation-assisted imaging produced high-quality, wide-field retinal images that demonstrate the potential of smartphone-based retinal cameras to be used for retinal disease screening.\n\nTranslational RelevanceEnhancement of smartphone-based retinal imaging through automation and software intelligence holds great promise for increasing the accessibility of retinal screening.

bioengineering↗