bioRxiv Science⌕ Search

Biology subjects

Weinfurtner, R. J.

Publications and source records attributed to Weinfurtner, R. J..

2 recordsLinked to original sources

Comparison of Total X-Ray Energy Absorbed by Fibroglandular Tissue and its Mass Derived from Full Field Digital Mammography and Digital Breast Tomosynthesis

This study investigated whether total x-ray energy absorbed by fibroglandular tissue and fibroglandular tissue mass derived from raw and clinical full field digital mammography (FFDM) images corresponded with the respective quantities derived from digital breast tomosynthesis (DBT). A total of 840 paired FFDM and DBT observations were analyzed separately for the craniocaudal (CC) and mediolateral oblique (MLO) orientations. Total absorbed x-ray energy and fibroglandular tissue mass were calculated using an automated breast density detection method in conjunction with the recorded average glandular dose. Relationships between FFDM and DBT quantities were evaluated in the log-log domain using linear and quadratic models, with model performance assessed by R2, adjusted R2, mean squared error (MSE), chi-square goodness-of-fit tests, and residual analysis. Strong associations were observed between FFDM and respective DBT quantities. For raw FFDM, linear energy models produced R2 values of 0.734 and 0.901 for the CC and MLO views, respectively, while the corresponding mass models produced R2 values of 0.634 and 0.870. Inclusion of a quadratic term improved model performance modestly. For clinical FFDM, linear energy models produced R2 values of 0.854 and 0.919, while the corresponding mass models produced R2 values of 0.721 and 0.812. The first-order coefficients for the clinical-image energy models were approximately unity (0.99-1.05), and inclusion of the quadratic term produced negligible changes in model performance and residual distributions. The goodness-of-fit tests did not reject adequate fit for any model. Clinical FFDM images can therefore provide estimates of total absorbed x-ray energy and fibroglandular tissue mass that are strongly associated with corresponding quantities derived from DBT. The approximately unit first-order coefficients and minimal benefit from quadratic modeling support a simple linear log-log calibration for clinical FFDM. This approach may facilitate combining FFDM and DBT based data in larger retrospective and longitudinal studies of cumulative mammographic x-ray exposure. These findings demonstrate proof-of-concept internal consistency but do not establish absolute dosimetric accuracy.

bioinformatics↗

Breast Density Analysis of Digital Breast Tomosynthesis

We evaluated an automated percentage of breast density (BD) technique (PDa) with digital breast tomosynthesis (DBT) data. The approach is based on the wavelet expansion followed by analyzing signal dependent noise. Several measures were investigated as risk factors: normalized volumetric; total dense volume; average of the DBT slices (slice-mean); a two-dimensional (2D) metric applied to the synthetic images; and the mean and standard deviations of the pixel values. Volumetric measures were derived theoretically, and PDa was modeled as a function of compressed breast thickness. An alternative method for constructing synthetic 2D mammograms was investigated using the volume results. A matched case-control study (n = 426 pairs) was analyzed. Conditional logistic regression modeling, controlling body mass index and ethnicity, was used to estimate odds ratios (ORs) for each measure with 95% confidence intervals provided parenthetically. There were several significant findings: volumetric measure [OR = 1.43 (1.18, 1.72)], which produced an identical OR as the slice-mean measure as predicted; [OR =1.44 (1.18, 1.75)] when applied to the synthetic images; and mean of the pixel values (volume or 2D synthetic) [ORs [~] 1.31 (1.09, 1.57)]. PDa was modeled as 2nd degree polynomial (concave-down): its maximum value occurred at 0.41x(compressed breast thickness), which was similar across case-control groups, and was significant from this position [OR = 1.47 (1.21, 1.78)]. A standardized 2D synthetic image was produced, where each pixel value represents the percentage of BD above its location. The significant findings indicate the validity of the technique. Derivations supported by empirical analyses produced a new synthetic 2D standardized image technique. Ancillary to the objectives, the results provide evidence for understanding the percentage of BD measure applied to 2D mammograms. Notwithstanding the findings, the study design provides a template for investigating other measures such as texture.

biophysics↗