bioRxiv Science⌕ Search

Biology subjects

Weber, T. D.

Publications and source records attributed to Weber, T. D..

4 recordsLinked to original sources

High-speed, multi-Z confocal microscopy for voltage imaging in densely labeled neuronal populations

Genetically encoded voltage indicators (GEVIs) hold great promise for monitoring neuronal population activity, but GEVI imaging in dense neuronal populations remains difficult due to a lack of contrast and/or speed. To address this challenge, we developed a novel confocal microscope that allows simultaneous multiplane imaging with high-contrast at near-kHz rates. This approach enables high signal-to-noise ratio voltage imaging in densely labeled populations and minimizes optical crosstalk during concurrent optogenetic photostimulation.

neuroscience↗

Sensitivity optimization of a rhodopsin-based fluorescent voltage indicator

The ability to optically image cellular transmembrane voltage at millisecond-timescale resolution can offer unprecedented insight into the function of living brains in behaving animals. The chemigenetic voltage indicator Voltron is bright and photostable, making it a favorable choice for long in vivo imaging of neuronal populations at cellular resolution. Improving the voltage sensitivity of Voltron would allow better detection of spiking and subthreshold voltage signals. We performed site saturation mutagenesis at 40 positions in Voltron and screened for increased {Delta}F/F0 in response to action potentials (APs) in neurons. Using a fully automated patch-clamp system, we discovered a Voltron variant (Voltron.A122D) that increased the sensitivity to a single AP by 65% compared to Voltron. This variant (named Voltron2) also exhibited approximately 3-fold higher sensitivity in response to sub-threshold membrane potential changes. Voltron2 retained the sub-millisecond kinetics and photostability of its predecessor, with lower baseline fluorescence. Introducing the same A122D substitution to other Ace2 opsin-based voltage sensors similarly increased their sensitivity. We show that Voltron2 enables improved sensitivity voltage imaging in mice, zebrafish and fruit flies. Overall, we have discovered a generalizable mutation that significantly increases the sensitivity of Ace2 rhodopsin-based sensors, improving their voltage reporting capability.

neuroscience↗

In vivo corneal and lenticular microscopy with asymmetric fundus retroillumination

We describe a new technique for non-contact in vivo corneal and lenticular microscopy. It is based on fundus retro-reflection and back-illumination of the crystalline lens and cornea. To enhance phase-gradient contrast, we apply asymmetric illumination by illuminating one side of the fundus. The technique produces micron-scale lateral resolution across a 1-mm diagonal field of view. We show representative images of the epithelium, the subbasal nerve plexus, large stromal nerves, dendritic immune cells, endothelial nuclei, and the anterior crystalline lens, demonstrating the potential of this instrument for clinical applications.

biophysics↗

Non-mydriatic chorioretinal imaging in a transmission geometry and application to retinal oximetry

The human retina is typically imaged in a reflection geometry, where light is delivered through the pupil and images are formed from the light reflected back from the retina. In this configuration, artifacts caused by retinal surface reflex are often encountered, which complicate quantitative interpretation of the reflection images. We present an alternative illumination method, which avoids these artifacts. The method uses deeply penetrating near-infrared (NIR) light delivered transcranially from the side of the head, and exploits multiple scattering to redirect a portion of the light towards the posterior eye. This unique transmission geometry simplifies absorption measurements and enables flash-free, non-mydriatic imaging as deep as the choroid. Images taken with this new transillumination approach are applied to retinal oximetry.\n\nOCIS codes: (170.4460) Ophthalmic optics and devices; (170.2945) Illumination design; (170.1470) Blood or tissue constituent monitoring.

biophysics↗