bioRxiv ScienceSearch

Biology subjects

Huang, S. Y.

Publications and source records attributed to Huang, S. Y..

5 recordsLinked to original sources

High-fidelity, high-spatial-resolution diffusion MRI of the ex-vivo whole human brain on the 3T Connectom scanner using structured low-rank EPI ghost correction

Diffusion MRI (dMRI) of whole, intact, fixed postmortem human brain at high spatial resolution serves as key bridging technology for 3D mapping of structural connectivity and tissue microstructure at the mesoscopic scale. Ex vivo dMRI offers superior spatial resolution compared to in vivo dMRI but comes with its own technical challenges due to the significantly reduced T2 relaxation times and decreased diffusivity incurred by tissue fixation. The altered physical properties of fixed tissue necessitate the use of alternative acquisition strategies to preserve SNR and achieve sufficient diffusion weighting. Multi-shot or segmented 3D echo planar imaging (EPI) sequences have been used to shorten echo times (TEs) with reduced distortions from field inhomogeneity and eddy currents on small-bore MR scanners and have been adopted for high b-value dMRI of ex vivo whole human brain specimens. The advent of stronger gradients on human MRI scanners has led to improved image quality and a wider range of diffusion-encoding parameters for dMRI but at the cost of more severe eddy currents that result in spatial and temporal variations in the background magnetic field, which cannot be corrected for using standard vendor-provided ghost correction solutions. In this work, we show that conventional ghost correction techniques based on navigators and linear phase correction may be insufficient for EPI sequences using strong diffusion-sensitizing gradients in ex vivo dMRI experiments, resulting in orientationally biased dMRI estimates. This previously unreported problem is a critical roadblock in any effort to leverage scanners with ultra-high gradients for high-precision mapping of human neuroanatomy at the mesoscopic scale. We propose an advanced reconstruction method based on structured low-rank matrix modeling that reduces the ghosting substantially. We show that this method leads to more accurate and reliable dMRI metrics, as exemplified by diffusion tensor imaging and high angular diffusion imaging analyses in distributed neuroanatomical areas of fixed whole human brain specimens. Our findings advocate for the use of advanced reconstruction techniques for recovering unbiased metrics from ex vivo dMRI acquisitions and represent a crucial step toward making full use of strong diffusion-encoding gradients for neuroscientific studies seeking to study brain structure at multiple spatial scales.

neuroscience

Rapid simultaneous acquisition of macromolecular tissue volume, susceptibility, and relaxometry maps

PurposeA major obstacle to the clinical implementation of quantitative MR is the lengthy acquisition time required to derive multi-contrast parametric maps. We sought to reduce the acquisition time for quantitative susceptibility mapping (QSM) and macromolecular tissue volume (MTV) by acquiring both contrasts simultaneously by leveraging their redundancies. The Joint Virtual Coil concept with generalized autocalibrating partially parallel acquisitions (JVC-GRAPPA) was applied to reduce acquisition time further. MethodsThree adult volunteers were imaged on a 3T scanner using a multi-echo 3D GRE sequence acquired at three head orientations. MTV, QSM, R2*, T1, and proton density maps were reconstructed. The same sequence (GRAPPA R=4) was performed in subject #1 with a single head orientation for comparison. Fully sampled data was acquired in subject #2, from which retrospective undersampling was performed (R=6 GRAPPA and R=9 JVC-GRAPPA). Prospective undersampling was performed in subject #3 (R=6 GRAPPA and R=9 JVC-GRAPPA) using gradient blips to shift k-space sampling in later echoes. ResultsSubject #1s multi-orientation and single-orientation MTV maps were not significantly different based on RMSE. For subject #2, the retrospectively undersampled JVC-GRAPPA and GRAPPA generated similar results as fully sampled data. This approach was validated with the prospectively undersampled images in subject #3. Using QSM, R2*, and MTV, the contributions of myelin and iron content to susceptibility was estimated. ConclusionWe have developed a novel strategy to simultaneously acquire data for the reconstruction of five intrinsically co-registered 1-mm isotropic resolution multi-parametric maps, with a scan time of 6 minutes using JVC-GRAPPA.

bioengineering

A 48-Channel Receive Array Coil for Mesoscopic Diffusion-Weighted MRI of Human ex vivo Brain Imaging on the 3T Connectome Scanner

In vivo diffusion-weighted magnetic resonance imaging is limited in signal-to-noise-ratio (SNR) and acquisition time, which constrains spatial resolution to the macroscale regime. Ex vivo imaging, which allows for arbitrarily long scan times, is critical for exploring human brain structure in the mesoscale regime without loss of SNR. Standard head array coils designed for patients are sub-optimal for imaging ex vivo whole brain specimens. The goal of this work was to design and construct a 48-channel ex vivo whole brain array coil for high-resolution and high b-value diffusion-weighted imaging on a 3T Connectome scanner. The coil was validated with bench measurements and characterized by imaging metrics on an agar brain phantom and an ex vivo human brain sample. The two-segment coil former was constructed for a close fit to a whole human brain, with small receive elements distributed over the entire brain. Imaging tests including SNR and G-factor maps were compared to a 64-channel head coil designed for in vivo use. There was a 2.9-fold increase in SNR in the peripheral cortex and a 1.3-fold gain in the center when compared to the 64-ch head coil. The 48-channel ex vivo whole brain coil also decreases noise amplification in highly parallel imaging, allowing acceleration factors of approximately one unit higher for a given noise amplification level. The acquired diffusion-weighted images in a whole ex vivo brain specimen demonstrate the applicability of the developed coil for high-resolution and high b-value diffusion-weighted ex vivo brain MRI studies.

bioengineering

In vivo human whole-brain Connectom diffusion MRI dataset at 760 μm isotropic resolution

We present a whole-brain in vivo diffusion MRI (dMRI) dataset acquired at 760 m isotropic resolution and sampled at 1260 q-space points across 9 two-hour sessions on a single healthy subject. The creation of this benchmark dataset is possible through the synergistic use of advanced acquisition hardware and software including the high-gradient-strength Connectom scanner, a custom-built 64-channel phased-array coil, a personalized motion-robust head stabilizer, a recently developed SNR-efficient dMRI acquisition method, and parallel imaging reconstruction with advanced ghost reduction algorithm. With its unprecedented resolution, SNR and image quality, we envision that this dataset will have a broad range of investigational, educational, and clinical applications that will advance the understanding of human brain structures and connectivity. This comprehensive dataset can also be used as a test bed for new modeling, sub-sampling strategies, denoising and processing algorithms, potentially providing a common testing platform for further development of in vivo high resolution dMRI techniques. Whole brain anatomical T1-weighted and T2-weighted images at submillimeter scale along with field maps are also made available.

neuroscience

Improved cortical surface reconstruction using sub-millimeter resolution MPRAGE by image denoising

Automatic cerebral cortical surface reconstruction is a useful tool for cortical anatomy quantification, analysis and visualization. Recently, the Human Connectome Project and several studies have shown the advantages of using T1-weighted magnetic resonance (MR) images with sub-millimeter isotropic spatial resolution instead of the standard 1-millimeter isotropic resolution for improved accuracy of cortical surface positioning and thickness estimation. Nonetheless, sub-millimeter resolution images are noisy by nature and require averaging multiple repetitions to increase the signal-to-noise ratio for precisely delineating the cortical boundary. The prolonged acquisition time and potential motion artifacts pose significant barriers to the wide adoption of cortical surface reconstruction at sub-millimeter resolution for a broad range of neuroscientific and clinical applications. We address this challenge by evaluating the cortical surface reconstruction resulting from denoised single-repetition sub-millimeter T1-weighted images. We systematically characterized the effects of image denoising on empirical data acquired at 0.6 mm isotropic resolution using three classical denoising methods, including denoising convolutional neural network (DnCNN), block-matching and 4-dimensional filtering (BM4D) and adaptive optimized non-local means (AONLM). The denoised single-repetition images were found to be highly similar to 6-repetition averaged images, with a low whole-brain averaged mean absolute difference of [~]0.016, high whole-brain averaged peak signal-to-noise ratio of [~]33.5 dB and structural similarity index of 0.92, and minimal gray matter-white matter contrast loss (2% to 9%). The whole-brain mean absolute discrepancies in gray-white surface placement, gray-CSF surface placement and cortical thickness estimation were lower than 165 m, 155 m and 145 m--sufficiently accurate for most applications. The denoising performance is equivalent to averaging [~]2.5 repetitions of the data in terms of image similarity, and 1.6-2.2 repetitions in terms of the cortical surface placement accuracy. The scan-rescan precision of the cortical surface positioning and thickness estimation was lower than 170 m. Our unique dataset and systematic characterization support the use of denoising methods for improved cortical surface reconstruction sub-millimeter resolution.

bioengineering