bioRxiv Science⌕ Search

Biology subjects

Glaser, A. K.

Publications and source records attributed to Glaser, A. K..

7 recordsLinked to original sources

Grayscale 4D Biomaterial Customization at High Resolution and Scale

Hydrogel biomaterials have proven indispensable for three-dimensional (3D) cell culture but have fallen short in replicating the innate physiochemical complexity of real tissue. Though traditional photolithography affords localized material manipulation, robust methods that govern when, where, and to what extent such phototailoring occurs throughout materials would be profoundly enabling towards fabricating more-realistic 3D tissue constructs. Here, we introduce "grayscale image z-stack-guided multiphoton optical-lithography" (GIZMO) as a generalizable and intuitive strategy to rapidly photomodulate materials in full 3D non-binary patterns at submicron resolutions spanning large volumes (>mm3). Highlighting its versatility, we employ GIZMO to variably photopattern biomolecule release from, protein immobilization to, and degradation within hydrogels based on biologically derived or synthetic grayscale image stacks with unprecedented complexity. We anticipate that GIZMO will enable new opportunities to probe and manipulate cell fates, as well as to engineer complex functional tissue.

bioengineering↗

An end-to-end workflow for non-destructive 3D pathology

Recent advances in 3D pathology offer the ability to image orders-of-magnitude more tissue than conventional pathology while providing a volumetric context that is lacking with 2D tissue sections, all without requiring destructive tissue sectioning. Generating high-quality 3D pathology datasets on a consistent basis is non-trivial, requiring careful attention to many details regarding tissue preparation, imaging, and data/image processing in an iterative process. Here we provide an end-to-end protocol covering all aspects of a 3D pathology workflow (using light-sheet microscopy as an illustrative imaging platform) with sufficient detail to perform well-controlled preclinical and clinical studies. While 3D pathology is compatible with diverse staining protocols and computationally generated color palettes for visual analysis, this protocol will focus on a fluorescent analog of hematoxylin and eosin (H&E), which remains the most common stain for gold-standard diagnostic determinations. We present our guidelines for a broad range of end-users (e.g., biologists, clinical researchers, and engineers) in a simple tutorial format.

pathology↗

Performance trade-offs for single- and dual-objective light-sheet microscope designs

Light-sheet microscopy (LSM) has emerged as a powerful tool for high-speed volumetric imaging of live model organisms and large optically cleared specimens. When designing cleared-tissue LSM systems with certain desired imaging specifications (e.g. resolution, contrast, and working distance), various design parameters must be taken into consideration. In order to elucidate some of the key design trade-offs for LSM systems, we present a diffraction-based analysis of single- and dual-objective LSM configurations where Gaussian illumination is utilized. Specifically, we analyze the effects of the illumination and collection numerical aperture (NA), as well as their crossing angle, on spatial resolution and contrast. Assuming an open-top light-sheet (OTLS) architecture, we constrain these parameters based on fundamental geometric considerations as well as those imposed by currently available microscope objectives. In addition to revealing the performance tradeoffs of various single- and dual-objective LSM configurations, our analysis showcases the potential advantages of a novel, non-orthogonal dual-objective (NODO) architecture, especially for moderate-resolution imaging applications (collection NA of 0.5 to 0.8).

bioengineering↗

A hybrid open-top light-sheet microscope for multi-scale imaging of cleared tissues

Light-sheet microscopy has emerged as the preferred means for high-throughput volumetric imaging of cleared tissues. However, there is a need for a user-friendly system that can address imaging applications with varied requirements in terms of resolution (mesoscopic to sub-micrometer), sample geometry (size, shape, and number), and compatibility with tissue-clearing protocols and sample holders of various refractive indices. We present a hybrid system that combines a novel non-orthogonal dual-objective and conventional (orthogonal) open-top light-sheet architecture for versatile multi-scale volumetric imaging.

bioengineering↗

FalseColor-Python: a rapid intensity-leveling and digital-staining package for fluorescence-based slide-free digital pathology

Slide-free digital pathology techniques, including nondestructive 3D microscopy, are gaining interest as alternatives to traditional slide-based histology. In order to facilitate clinical adoption of these fluorescence-based techniques, software methods have been developed to convert grayscale fluorescence images into color images that mimic the appearance of standard absorptive chromogens such as hematoxylin and eosin (H&E). However, these false-coloring algorithms often require manual and iterative adjustment of parameters, with results that can be inconsistent in the presence of intensity nonuniformities within an image and/or between specimens (intra- and inter-specimen variability). Here, we present an open-source (Python-based) rapid intensity-leveling and digital-staining package that is specifically designed to render two-channel fluorescence images (i.e. a fluorescent analog of H&E) to the traditional H&E color space for 2D and 3D microscopy datasets. However, this method can be easily tailored for other false-coloring needs. Our package offers (1) automated and uniform false coloring in spite of uneven staining within a large thick specimen, (2) consistent color-space representations that are robust to variations in staining and imaging conditions between different specimens, and (3) GPU-accelerated data processing to allow these methods to scale to large datasets. We demonstrate this platform by generating H&E-like images from cleared tissues that are fluorescently imaged in 3D with open-top light-sheet (OTLS) microscopy, and quantitatively characterizing the results in comparison to traditional slide-based H&E histology.Competing Interest StatementA.K.G. and J.T.C.L. are co-founders and shareholders of Lightspeed Microscopy Inc.View Full Text

pathology↗

Multi-immersion open-top light-sheet microscope for high-throughput imaging of cleared tissues

Recent advances in optical clearing and light-sheet microscopy have provided unprecedented access to structural and molecular information from intact tissues. However, current light-sheet microscopes have imposed constraints on the size, shape, number of specimens, and compatibility with various clearing protocols. Here we present a multi-immersion open-top light-sheet microscope that enables simple mounting of multiple specimens processed with a variety of protocols, which will facilitate wider adoption by preclinical researchers and clinical laboratories. One Sentence SummaryGlaser et al. describe a multi-immersion open-top light-sheet microscope that enables simple and high-throughput imaging of large numbers of preclinical and clinical specimens prepared with a variety of clearing protocols.

bioengineering↗

Multidirectional digital scanned light-sheet microscopy enables uniform fluorescence excitation and contrast-enhanced imaging

Light-sheet fluorescence microscopy (LSFM) has emerged as a powerful method for rapid and optically efficient 3D microscopy. Initial LSFM designs utilized a static sheet of light, termed selective plane illumination microscopy (SPIM), which exhibited shadowing artifacts and deteriorated contrast due to light scattering. These issues have been addressed, in part, by multidirectional selective plane illumination microscopy (mSPIM), in which rotation of the light sheet is used to mitigate shadowing artifacts, and digital scanned light-sheet microscopy (DSLM), in which confocal line detection is used to reject scattered light. Here we present a simple passive multidirectional digital scanned light-sheet microscopy (mDSLM) architecture that combines the benefits of mSPIM and DSLM. By utilizing an elliptical Gaussian beam with increased angular diversity in the imaging plane, mDSLM provides shadow-free contrast-enhanced imaging of fluorescently labeled samples.\n\nOne Sentence SummaryGlaser et al. describe a light-sheet microscopy architecture that enables passive multidirectional illumination with confocal line detection to enable both uniform fluorescence excitation and contrast-enhanced imaging of fluorescently labeled samples.

bioengineering↗