bioRxiv Science⌕ Search

bioRxiv · 10.64898/2026.10.15.759481

Inferring protein-induced spontaneous curvature of lipid bilayers from molecular simulation

Abstract

Proteins and lipids of a biological cell work together to reshape the membranes in which they reside. Membrane reshaping is necessary for vesicular traffic and maintenance of organelle shape and structure. Curvature is the fundamental mathematical description of the local shape of a surface. Through the well-established Helfrich/Canham/Evans model of bilayer shape, curvature sensing and induction are both consequences of a protein's spontaneous curvature, the local curvature at which the Helfrich model energy is a minimum. This paper describes a straightforward approach for estimating the strength and sign of a bilayer-associated molecule's curvature induction from molecular simulation: Correlating the molecule's lateral position with curvature on thermally-fluctuating bilayer modes. Example demonstrations range from a large multi-pass coarse-grained transmembrane protein to an all-atom amphipathic helical segment. Quantification of these systems is placed in the context of experiments seeking the same strength and sign of curvature induction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Hossein, A., Brunet, M. A., Englander, N., Dadhania, J., Sodt, A. J.. 2026-10-19. Inferring protein-induced spontaneous curvature of lipid bilayers from molecular simulation. https://doi.org/10.64898/2026.10.15.759481

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Fluorescent Biosensors for Cryogenic Correlative Light and Electron Microscopy

Cryogenic electron tomography provides nanometer-scale views of subcellular structures but lacks essential physiological context, such as the metabolic state or ion concentration. To bridge this gap, we incorporated fluorescent biosensors into a cryogenic correlative light and electron microscopy workflow, enabling direct measurement of physiological conditions alongside structural data. Here, we focused on establishing and calibrating biosensors for calcium, pH, and osmotic stress at cryogenic conditions through an in vitro workflow in which biosensors were frozen in defined chemical environments and then imaged ratiometrically. We then applied these biosensors across a range of sample types: an osmotic stress sensor in Saccharomyces cerevisiae, a calcium sensor in human U2OS cells, and a pH sensor in the bacterium Halothiobacillus neapolitanus. This approach links localized physiological changes to the 3D structures of macromolecules and their organization in situ.

biophysics↗

Structural order emerges without mechanical order inside living cells

Intracellular organization is vital for cell function, and disruption of organelle positioning is connected to severe diseases, such as cancer. Given the small length scale of cells and the importance of Brownian motion, maintaining intracellular organization requires mechanical interactions to remain stable. Here, we test the common view that intracellular organization is reflected in intracellular mechanical properties. Using the recently introduced active mechanical fingerprint, we quantify intracellular mechanical properties and active forces to create mechanical maps of patterned RPE1 cells. The organization of actin, microtubules, the Golgi apparatus, the endoplasmic reticulum, and the nucleus reveals pronounced structural polarization across the cell population. To overcome limitations of simple averages, we use a Wasserstein barycenter to calculate an optimal intracellular organization that explains all measurements with minimal cellular distortion. To our surprise, and in contrast to previous reports, we find neither a statistically significant spatial mechanical pattern nor any relevant correlation between the tested structures and intracellular mechanical properties. While there is clear local mechanical anisotropy, the large heterogeneity of mechanical values outweighs any intracellular mechanical gradient. This is further supported by large cell-to-cell variability. Thus, despite having the same genome, cells function properly while their intracellular mechanical properties vary over two orders of magnitude.

biophysics↗

CALISTO: A Standardized and Open-Source Software for Magnetic Tweezer Force Calibration

Magnetic tweezers (MT) enable multiplexed single-molecule force spectroscopy while applying controlled forces and torques to biomolecules. They resolve forces below 1 pN and maintain constant forces over extended periods, but accurate calibration remains challenging due to drift, tracking artifacts, camera noise, and bead variability. Here, we present CALISTO (CALIbration Suite for magnetic Tweezer Operation), an open-source software for MT force calibration. CALISTO analyzes position traces of DNA-tethered magnetic beads and surface-bound reference beads for drift correction. It implements three thermal-motion-based calibration methods: power spectral density, Allan variance, and Hadamard variance, with the latter providing increased robustness against drift and correlated measurement noise. The graphical user interface combines automated analysis with user-guided quality control, including reference bead selection, z-offset determination, magnet-position classification, bead-wise force estimation, and tether extension analysis. Together, these steps generate a master force calibration curve. We systematically evaluated their effects on calibration performance. The largest improvement resulted from automated filtering of problematic force plateaus using time-series characterization to identify traces affected by drift, tracking artifacts, or irregular fluctuations. Filtering reduced scatter and improved force estimation while preserving the underlying force-magnet position relationship. CALISTO thus provides a standardized, reproducible framework for reliable magnetic-tweezers force calibration.

biophysics↗