FLEX-DBS: a flexible wireless platform for bilateral constant-current deep brain stimulation in freely moving rodents

Abstract

Background: Preclinical deep brain stimulation (DBS) in rodents is central to understanding how DBS works, but most rodent DBS is delivered through a tether, which constrains behavior, home-cage experiments and uninterrupted stimulation. Most long-runtime wireless mouse stimulators achieve their runtimes by setting stimulation parameters before or around implantation and operating from supplies of about 3 V. New method: FLEX-DBS (Flexible Deep Brain Stimulation) is a head-mounted, battery-powered stimulator that delivers bilateral constant-current stimulation from improved Howland current pumps on +/-5 V rails. Amplitude, pulse width and frequency are programmable in continuous and burst modes from an iOS application over Bluetooth Low Energy, and stimulation continues autonomously after the phone disconnects. The device measures 19.5 x 22.5 x 8.72 mm, weighs 3.71 g in operation and runs on two size-13 zinc-air cells, which are exchanged by briefly detaching the device, pausing stimulation only for the exchange. Results: Into a 1 k{Omega} bench load, delivered current increased approximately linearly with the amplitude setting and was repeatable from pulse to pulse, with an asymmetric biphasic waveform whose recovery phase ran at about one fifth of the stimulating amplitude. Battery current was 1.47-1.89 mA in standby and 3.15-3.42 mA during stimulation at amplitude settings of 60-400 A, giving a projected three days of continuous stimulation per pair of cells. Firmware v0.5 left a net charge of 26-35 % of the stimulating-phase charge per pulse into 1 k{Omega}. Into 47 k{Omega}, within the in vivo load range, stimulating current was compliance-limited at 93 A. Pulse-derived estimates of the effective load presented by five implanted platinum electrodes in three mice had weekly means of 43-54 k{Omega} over eight weeks (32-80 k{Omega} across individual sessions), placing the maximum regulated current near 90 A (81-101 A at the weekly means). Analysis of the current-pump network bounds load-dependent current error at 3-8% for these loads. In vivo, we delivered cingulate FLEX-DBS at high amplitude settings intended to evoke a robust stimulation-associated behavioral phenotype in six mice. Time spent immobile in an open field rose from 46.5% at baseline to 75.7% during stimulation (a 62.7% increase in the group mean) and remained elevated after stimulation ended; without a sham control, this increase cannot be separated from within-session habituation. Comparison with existing methods: Among the published wireless rodent stimulators compared here, several offer some of these capabilities, but none combines bilateral constant current output, real-time wireless control that continues as autonomous stimulation after disconnect, and both continuous and burst modes; FLEX-DBS does so at the cost of runtime measured in days rather than weeks. Conclusions: FLEX-DBS is designed for untethered DBS experiments in which parameters must be set, changed and verified at the cage. Its measured power consumption permits a projected three days of continuous operation per cell pair; firmware v0.5 requires improved charge balancing before prolonged in vivo stimulation. The electrode load, rather than the programmable range, sets the usable stimulation amplitude in vivo. In vivo, stimulation at high amplitude settings was associated with increased immobility, consistent with effective stimulation through implanted electrodes; electrode impedance and delivered current were not measured in these mice.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Graham, R. D., Creed, M. C., Gaidica, M.. 2026-10-12. FLEX-DBS: a flexible wireless platform for bilateral constant-current deep brain stimulation in freely moving rodents. https://doi.org/10.64898/2026.10.09.757775

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Development of a Low-cost Extrusion Multi-nozzle 3D Bioprinter for Complex Constructs

Extrusion-based multi-material bioprinting is a promising approach for fabricating complex tissue constructs, but current systems often require expensive hardware or support only one or a few numbers of bioinks. In this study, a low-cost, compact, and versatile multi-nozzle bioprinter (MNB) system was developed for pneumatic extrusion of up to 10 different inks using a rotational head. The system was integrated with a commercial 3D printer platform and controlled using custom G-code commands. Backlash compensation and nozzle-specific calibrations were experimentally determined to minimize positioning errors and airflow misalignment. The developed system showed stable repeatability in both clockwise and counterclockwise movements. Lines and various structures were successfully printed with different nozzle-switching directions and printing sequences. Representative structures including a diamond pattern, a multilayer scaffold, a pyramid structure, and a kidney-like construct were successfully fabricated. These results demonstrate that the proposed MNB system can produce complex 2D and 3D multi-material structures with good positional accuracy and repeatability.

bioengineering↗

FluOpti: an open-source system for programmable whole-plate optogenetics and multi-fluorescence imaging

Bacteria are able to self-organize into complex spatial communities, such as colonies, biofilms and swarms. Probing cells and gene networks with dynamic stimuli while preserving their spatial organization is therefore essential for understanding how bacterial communities organize across spatial and temporal scales. Optogenetics offers a powerful approach for such a task given the precise control of stimulus delivery without the perturbations normally associated with the addition of liquid inducers. However, most optogenetics devices have been developed to work with liquid cell cultures or to deliver a spatial pattern without the concurrent recording of gene responses and colony growth. Here, we describe FluOpti, an open source, low-cost device for controlling gene expression, through programmable light inputs, and recording multi-fluorescence responses and colony growth across whole petri dishes. White light LEDs are used for brightfield imaging while green and red LEDs are used as optogenetic inputs to activate and inactivate target genes via the CcaS/R two component system in E. coli. Low cost blue and orange acrylic are used as excitation and emission filters for fluorescence imaging, respectively. We developed custom software to analyze colony growth and optogenetic responses from 72-hour time-lapse experiments. A mathematical model was developed to predict gene expression levels in response to green-to-red light ratio stimuli. We use FluOpti to reveal a spatially structured response to optogenetic stimuli, with gene activation rates differing in cells located at the center and edge of colonies. to validate its use at a whole petri dish scale, FluOpti was used to depict how Voronoi territories can act as predictors of colony size, in congruence with previous studies. Together, these results demonstrate the utility of the device for studying gene networks at multiple spatio-temporal scales, from individual colonies to the whole petri dish. Performing optogenetics studies in whole petri dishes while preserving spatial arrangements could offer valuable insights into the spatial biology of gene networks in microbial populations.

bioengineering↗

Denoising broadband CARS hyperspectral images on variance-stabilized data: a unified benchmark

Broadband coherent anti-Stokes Raman scattering (BCARS) enables label-free hyperspectral chemical imaging, but weak signal components are often obscured by heteroscedastic noise. Here, we develop a physics-based variance stabilization transform and benchmark six hyperspectral denoising methods to identify effective strategies for BCARS noise reduction. The transform yields nearly intensity-independent noise variance while preserving the dispersive Raman response. Within this framework, we compare singular value decomposition, BM4D, Noise2Noise, deep image prior, self-supervised diffusion, and a cross-covariance-based singular value decomposition method (CCV) introduced here, using a shared phase-retrieval pipeline. Evaluation includes five simulated hyperspectral cubes with exact ground truth and experimental measurements of glycerol, polystyrene beads, and Caenorhabditis elegans. In simulations, variance stabilization reduces the ratio of maximum to minimum channel noise variance from approximately 72 to 1.2. Deep image prior and self-supervised diffusion achieve the highest mean foreground peak signal-to-noise ratios. CCV matches the mean foreground structural similarity of deep image prior with substantially shorter runtime and no per-cube rank tuning. Experimental comparisons reveal sample-dependent performance. These results establish physics-based variance stabilization as a common framework for adapting and evaluating hyperspectral denoisers for BCARS, with CCV offering a practical balance of reconstruction fidelity, computational speed, and automated operation.

bioengineering↗