bioRxiv Science⌕ Search

bioRxiv · 10.64898/2026.10.09.757630

TRF2 mediates force-resistant bridging of distal telomeric DNA repeats

Abstract

Shelterin binds telomeres, regulates telomere length, and protects chromosome ends from mis-repair, which is essential for genome stability. Telomere end-protection uniquely depends on the TRF2 subunit, which assembles telomeric DNA into a protective T-loop structure in vivo, yet the biochemical mechanism underlying this process remains unresolved. Using single-molecule optical tweezers and atomic force microscopy, we show that the human shelterin complex tethers distal telomeric DNA repeats, looping the intervening DNA. These bridges withstand tens of piconewtons of applied load, rupture at a force that scales with telomeric repeat number and re-form on relaxation. Structure-function analysis demonstrates that this force-resistant tethering is TRF2-dependent under our conditions and depends on multiple interfaces, with the TRFH domain making a major but non-exclusive contribution: introducing the TRF2 TRFH domain into TRF1 is sufficient to confer tethering, whereas its deletion from TRF2 reduces but does not abolish activity. We propose telomeric dsDNA tethering by TRF2 as a candidate first step in T-loop formation, preceding invasion of the telomeric 3' ssDNA overhang.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Newton, M. D., Catley, T. E., Whittle, S., Galanti, L., Wiggins, L. L., Holmes, E. P., Daccache, D., Anand, R., Allwood, E. G., Greensill, M., Segura-Bayona, S., Belan, O., Gamill, M. C., Maslen, S., Skehel, M., Pyne, A. L. B., Boulton, S. J.. 2026-10-11. TRF2 mediates force-resistant bridging of distal telomeric DNA repeats. https://doi.org/10.64898/2026.10.09.757630

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Structural order emerges without mechanical order inside living cells

Intracellular organization is vital for cell function, and disruption of organelle positioning is connected to severe diseases, such as cancer. Given the small length scale of cells and the importance of Brownian motion, maintaining intracellular organization requires mechanical interactions to remain stable. Here, we test the common view that intracellular organization is reflected in intracellular mechanical properties. Using the recently introduced active mechanical fingerprint, we quantify intracellular mechanical properties and active forces to create mechanical maps of patterned RPE1 cells. The organization of actin, microtubules, the Golgi apparatus, the endoplasmic reticulum, and the nucleus reveals pronounced structural polarization across the cell population. To overcome limitations of simple averages, we use a Wasserstein barycenter to calculate an optimal intracellular organization that explains all measurements with minimal cellular distortion. To our surprise, and in contrast to previous reports, we find neither a statistically significant spatial mechanical pattern nor any relevant correlation between the tested structures and intracellular mechanical properties. While there is clear local mechanical anisotropy, the large heterogeneity of mechanical values outweighs any intracellular mechanical gradient. This is further supported by large cell-to-cell variability. Thus, despite having the same genome, cells function properly while their intracellular mechanical properties vary over two orders of magnitude.

biophysics↗

CALISTO: A Standardized and Open-Source Software for Magnetic Tweezer Force Calibration

Magnetic tweezers (MT) enable multiplexed single-molecule force spectroscopy while applying controlled forces and torques to biomolecules. They resolve forces below 1 pN and maintain constant forces over extended periods, but accurate calibration remains challenging due to drift, tracking artifacts, camera noise, and bead variability. Here, we present CALISTO (CALIbration Suite for magnetic Tweezer Operation), an open-source software for MT force calibration. CALISTO analyzes position traces of DNA-tethered magnetic beads and surface-bound reference beads for drift correction. It implements three thermal-motion-based calibration methods: power spectral density, Allan variance, and Hadamard variance, with the latter providing increased robustness against drift and correlated measurement noise. The graphical user interface combines automated analysis with user-guided quality control, including reference bead selection, z-offset determination, magnet-position classification, bead-wise force estimation, and tether extension analysis. Together, these steps generate a master force calibration curve. We systematically evaluated their effects on calibration performance. The largest improvement resulted from automated filtering of problematic force plateaus using time-series characterization to identify traces affected by drift, tracking artifacts, or irregular fluctuations. Filtering reduced scatter and improved force estimation while preserving the underlying force-magnet position relationship. CALISTO thus provides a standardized, reproducible framework for reliable magnetic-tweezers force calibration.

biophysics↗

A Planar Switching Neuron Shares Logarithmic First-Spike Latency with Its Three-Dimensional Parent But Not Its Onset Mechanism

Reducing an electronic neuron from three variables to two can preserve a familiar voltage trace while changing the underlying dynamics that create it. We examine this distinction in a piecewise-linear planar reformulation of the three-dimensional neurosimilator. The planar model produces repetitive spike-like excursions without an imposed reset and admits an exact linear solution inside each of six switching regions. Direct comparison reveals only partial agreement between the two models. Although both generate large voltage excursions and an event rate that rises with applied drive, their waveforms and frequency-current gains differ substantially. A reanalysis of the three-dimensional, near-threshold data also corrects an earlier interpretation: over the resolved interval, the first-spike latency depends logarithmically on the normalized distance from threshold, matching the behavior of the planar model. However, this common functional form does not imply a shared onset mechanism. The three-dimensional equilibrium branch reaches a saddle-node limit point, whereas the planar equilibrium remains a stable node until it exits its admissible region at a switching boundary. While a stagewise analytical reconstruction captures individual voltage excursions, crossing-time errors accumulate unless Newton corrections are applied. The reduced system is therefore a useful electronic neuron model with transparent switching dynamics, rather than a dynamically equivalent copy of its three-dimensional parent. \

biophysics↗