bioRxiv Science⌕ Search

bioRxiv · 10.64898/2026.08.06.743263

LATEER: Low-Cost Open-Source Platform for Electrical Stimulation and TEER Measurement in Human Cardiomyocytes

Abstract

Electrical stimulation (ES) and transepithelial/transendothelial electrical resistance (TEER) measurements are essential techniques in cell biology and tissue engineering, yet commercial devices for these applications cost between USD 2,500-9,000 and typically offer only one functionality. We present LATEER (Low-cost Arduino-based TEER and Electrical stimulation device), an open-source hardware platform that combines both ES and TEER measurement capabilities at a total cost below USD 100. The device features four independent channels, configurable pulsatile signals (amplitude up to 8.2 V, frequency 0.1-500 Hz, pulse width [&ge;]0.1 ms), and a resistance measurement range of 300 {Omega} to 1 M{Omega}, with <5% error for R {gtrsim} 4.7 k{Omega}. LATEER uses commercially available graphite pencil leads as electrodes ([~]USD 2 vs. USD 350 for commercial Ag/AgCl electrodes), which demonstrated excellent biocompatibility in cell culture. The system includes 3D-printed electrode holders compatible with standard 12-well and 24-well plates, allowing microscope visualization without electrode removal, and a Python-based graphical user interface for parameter configuration and real-time data acquisition. Because the electrodes remain fixed in the plate lid and only a single cable enters the incubator, both stimulation and resistance measurement can run continuously under standard culture conditions (37 {degrees}C, 5% CO2) without removing the plate or repositioning the electrodes, avoiding the temperature excursions and placement variability inherent to manual chopstick measurements. Validation with human pluripotent stem cell-derived cardiomyocytes demonstrated reliable frequency capture (electrical pacing) of the contracting monolayer, with a capture threshold between 250 and 400 mV/mm and controlled pacing across the 0.5-5 Hz range. TEER functionality was verified with mesenchymal stem cells, where the device resolved cell-density-dependent differences in electrical resistance in real time. All design files, firmware, and software are freely available under the CERN-OHL-S v2 license, enabling replication and customization by research laboratories worldwide. HighlightsO_LIAn open-source device combines electrical stimulation and TEER measurement under $100 C_LIO_LIGraphite electrodes offer biocompatibility at 0.6% cost of commercial alternatives C_LIO_LIFour independent channels with configurable parameters and real-time data logging. C_LIO_LIContinuous run setup in-incubator; no electrode repositioning needed C_LIO_LIValidated with stem cell-derived cardiomyocytes, achieving frequency capture (threshold 250-400 mV/mm) C_LIO_LI3D-printed holders enable microscope visualization without electrode removal C_LI Graphical abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=78 SRC="FIGDIR/small/743263v1_ufig1.gif" ALT="Figure 1"> View larger version (28K): org.highwire.dtl.DTLVardef@19e2eeorg.highwire.dtl.DTLVardef@181aeb4org.highwire.dtl.DTLVardef@f4b77aorg.highwire.dtl.DTLVardef@39cced_HPS_FORMAT_FIGEXP M_FIG C_FIG Specifications Table O_TBL View this table: org.highwire.dtl.DTLVardef@bd04c1org.highwire.dtl.DTLVardef@1831c4eorg.highwire.dtl.DTLVardef@b7698forg.highwire.dtl.DTLVardef@1736519org.highwire.dtl.DTLVardef@f2595c_HPS_FORMAT_FIGEXP M_TBL C_TBL

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

De Lillo, F., Smucler, J.. 2026-08-07. LATEER: Low-Cost Open-Source Platform for Electrical Stimulation and TEER Measurement in Human Cardiomyocytes. https://doi.org/10.64898/2026.08.06.743263

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

RNASeek: A Cross-Phyla Generative Foundation Model for Multipurpose RNA Modeling and Reinforcement Learning-Based Design

RNA plays central roles in regulating information flow and provides a versatile substrate for engineering biological functions. While large language models (LLMs) have transformed natural language processing and protein design, a general framework connecting RNA foundation models to functional sequence design remains limited. Here, we present RNASeek, a 1.6-billion-parameter generative foundation model built on a DeepSeek architecture and trained on a cross-phyla transcriptomic corpus for RNA sequence representation and generation. Natural-language tokens enable flexible conditional prediction and sequence design using a unified backbone. RNASeek captures species-specific transcript features and intron-exon boundaries in a zero-shot setting. We then fine-tune RNASeek to predict ribozyme self-cleavage activity and viral mRNA stability, revealing interpretable sequence features associated with function, including ribozyme loop flexibility and stem stability, as well as AU-rich motifs associated with mRNA stability. We use these functional predictors as reward models and apply Group Relative Policy Optimization (GRPO) to update the generation policy of RNASeek toward sequences with desired properties. GRPO-guided generation produces faster-cleaving ribozymes and stability-enhancing 3' UTRs while satisfying user-specified IUPAC constraints. Experimentally validated RNASeek-generated ribozymes achieve wild-type levels of activity, while RNASeek-generated 3' UTR sequences exceed the performance of the training data and benchmarked AI-generated 3' UTRs. Together, RNASeek establishes a unified pretrain-predict-optimize framework that connects learned RNA function to controllable de novo sequence design and provides a general strategy for engineering regulatory RNAs with desired properties.

bioengineering↗

Joint Vector Flow Mapping and Segmentation: Ill-Posedness,Differentiable Bayesian Inference, and Synthetic Vortex-FlowBenchmarks

Vector flow mapping (VFM) reconstructs left-ventricular (LV) blood velocity from color-Doppler echocardiography by combining the measured beamwise component with physical and regularizing constraints. Analysis of the discrete VFM formulation shows that the inverse problem is intrinsically ill posed: the occurrence of singular modes can be predicted from the geometry of the segmented blood-pool domain, the imposed boundary conditions, and the degree of smoothing. These modes can propagate uncertainty along entire transverse bands of the reconstructed velocity field, yet conventional VFM neither quantifies this uncertainty nor allows for correcting the blood-pool segmentation. We introduce Bayesian VFM (B--VFM), a hierarchical framework that jointly infers radial and transverse velocities, a probabilistic blood-pool mask, their spatially resolved uncertainties, and hyperparameters weighting Doppler and segmentation fidelity, mass conservation, boundary conditions, and smoothness. The discretized posterior admits a closed-form gradient and exact Hessian, enabling computationally efficient, gradient-based MAP estimation, sampling, and direct analysis of ill-posed modes. Posterior inference combines Gibbs sampling of conjugate Gamma-distributed hyperparameters with conditional maximum-a-posteriori estimation and a Laplace approximation for the high-dimensional velocity and mask fields. To accommodate systematic departures from planar mass conservation, B-VFM can learn the covariance of the planar divergence residual from an ensemble of flows and incorporate it as a structured model-discrepancy prior. Independent chains converged reproducibly, while covariance priors learned from flow ensembles illustrated how model discrepancies can be incorporated into the inference. B--VFM was evaluated using Lamb-Chaplygin dipoles under ideal conditions and with Doppler corruption, Doppler voids, and segmentation defects, and using the Hicks-Moffatt family of spherical vortices to assess violations of planar mass conservation. The method produced smooth reconstructions, localized uncertainty near unreliable measurements and regions of model inconsistency, and used flow information to correct segmentation errors. Within the tested vortex family, the data-informed planar divergence prior reduced velocity bias and mask distortion. B--VFM thus provides an uncertainty-aware reconstruction method and a flexible foundation for future VFM formulations incorporating additional priors, observations, and physical models. Future work will evaluate the method using clinical data and more complex three-dimensional benchmark flows.

bioengineering↗

Computational design of a versatile, zero-radius proximity labeling enzyme

The ability to map protein interactomes and organelle proteomes is foundational for achieving a molecular understanding of living cells. Proximity labeling (PL) provides a powerful strategy for this, but existing enzymes and photocatalysts are limited by their spatial resolution, reliance on biotin, and/or in vivo compatibility. Here we report FlexID, an engineered promiscuous ligase that catalyzes the rapid attachment of diverse small-molecule probes to proximal endogenous proteins. Critically, FlexID operates through a zero-radius, direct-contact mechanism, offering superior spatial precision compared to existing PL tools. We engineered FlexID by combining the strengths of sequence- and structure-trained computational models to enhance its catalytic activity and structural stability. Biophysical analysis revealed that specific conformational changes in FlexID improve its ability to recognize diverse target proteins while simultaneously preventing the premature release of the reactive intermediate. We demonstrate FlexID's versatility through in vivo proximity labeling, comprehensive organelle proteome mapping, and a high-throughput, fluorescence-based screen for molecular glues. Our work shows that computational methods can be harnessed to create mechanistically distinct PL enzymes and establishes FlexID as a flexible, high-resolution tool for mapping protein interactions and proteomes in living cells.

bioengineering↗