bioRxiv Science⌕ Search

bioRxiv · 10.64898/2026.06.24.733738

Indium Tin Oxide (ITO) Substrates Enable Coating-Free SEM Imaging and Simplified Preparation of Purified Fibrinogen Clots

Abstract

BackgroundScanning electron microscopy (SEM) is widely used to determine fibrin fiber structural properties such as fiber diameter and fiber length. However, conventional SEM preparation protocols are time-consuming and typically require conductive sputter coating. The coating process introduces an additional layer onto the sample surface and may influence measurements of nanoscale fiber structure. Furthermore, preparation of purified fibrinogen clots often follows protocols originally developed for plasma clots, resulting in unnecessary processing steps. ObjectiveTo evaluate indium tin oxide (ITO) as a flat, conductive substrate for SEM imaging of fibrin fibers, investigate the effects of sputter coating on measured fiber diameter, and develop a simplified SEM preparation protocol for purified fibrinogen clots. MethodsPlatelet-poor plasma clots and purified fibrinogen clots were formed on ITO substrates and imaged by SEM following 0 s, 45 s, or 90 s sputter coating. Fibrin fiber diameters were quantified and compared across coating conditions. For purified fibrinogen clots, an ITO-based simplified preparation protocol, in which clots were formed and imaged directly on the conductive ITO surface, was compared with a previously developed, standardized SEM protocol, in which clots were formed in microtube lids and subsequently transferred onto carbon tape for imaging. ResultsFiber diameter measurements were affected by sputter coating duration, with increasing coating time resulting in larger apparent fiber diameters. Plasma and purified fibrinogen clots exhibited distinct fiber diameter distributions and coating responses. For purified fibrinogen clots, the simplified ITO-based protocol produced fiber diameter measurements that were not significantly different from those obtained using the standardized lid-to-carbon-tape workflow when identical coating times were applied. ConclusionsITO provides a practical conductive substrate for SEM imaging of fibrin fibers and enables substantial simplification of purified fibrinogen clot preparation. When coating conditions are matched, the simplified ITO-based protocol yields fiber diameter measurements comparable to those obtained using the previously standardized lid-to-carbon-tape workflow. These findings support the use of ITO as an alternative conductive imaging substrate and provide a simplified workflow for SEM analysis of purified fibrinogen clots. By reducing washing and transfer steps, this workflow may also provide a useful platform for future controlled studies of fibrin interactions with added proteins or other associated components.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Cai, C., Flake, C., Nameny, A., Hudson, N. E., Bannish, B. E., Guthold, M.. 2026-06-30. Indium Tin Oxide (ITO) Substrates Enable Coating-Free SEM Imaging and Simplified Preparation of Purified Fibrinogen Clots. https://doi.org/10.64898/2026.06.24.733738

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Mechanism of molecular recognition revealed through dynamic drug binding pathways to SARS-CoV-2 main protease

Characterization of drug-binding pathways remains experimentally limited by transient intermediates and computationally challenging due to long timescales intractable for conventional molecular dynamics. To address these challenges, we combined solution NMR titrations with weighted ensemble (WE) enhanced sampling simulations to resolve atomistic pathways of nirmatrelvir binding to the SARS-CoV-2 main protease. NMR titration revealed residue-dependent heterogeneity spanning fast, intermediate, and slow exchange regimes. WE simulations complement the NMR by providing insights into unassigned residues and adding time-resolved and three-dimensional structural context. We map key interactions along two distinct binding pathways, provide dynamic explanations for residues involved in resistance, and capture unique backbone conformations compared to those sampled in unbound or bound states. Our comprehensive binding model is consistent with a combined conformational selection and induced fit mechanism in which early transient contacts are made with residues E47 and L50 and allosteric motions are centered around residue V204 of the distal domain. This synergistic application of WE and titration NMR enables a more comprehensive characterization of drug binding than either method alone, providing an integrated framework that may have broader applicability to defining structure-kinetic relationships and guiding design of next-generation inhibitors.

biophysics↗

A Minimally Perturbative DARPin Probe for Quantitative Fluorescence Imaging of the Human TCR-CD3 Complex

Fluorescence microscopy is a powerful tool for dissecting the molecular mechanisms of T-cell antigen recognition in living cells, but its quantitative insight critically depends on non-perturbative, high-quality probes. Here, we repurpose a small (~15 kDa) CD3epsilon-binding DARPin (designed ankyrin repeat proteins) to a fluorescent label for T-cell receptor (TCR)/CD3 complexes on primary human CD8+ T-cells, with the aim of generating a powerful tool for quantitative analysis, single-molecule tracking, and advanced imaging of TCR dynamics. We show that the DARPin binds CD3{varepsilon} with high affinity and selectivity and using single molecule tracking and brightness analysis, we characterize the TCR-CD3 diffusion behavior and show that the DARPin binds to both CD3epsilon; subunits. Importantly, labeling preserves antigen sensitivity: on supported lipid bilayers presenting cognate pMHC, T-cells remain responsive, assemble synapses, form TCR microclusters, and initiate signaling similar to unlabeled controls. We further demonstrate compatibility with lattice light-sheet microscopy for volumetric imaging of T-cell - APC interactions in living cells. Together, these results establish DARPins as versatile, minimally perturbative probes for high resolution, quantitative studies of T cell synapse organization and signaling.

biophysics↗

Monitoring intramolecular dynamics across two regions of the mouse prion protein during misfolding and oligomerization using fluorescence correlation spectroscopy

It is important to determine whether native state dynamics drive the misfolding and oligomerization of the prion protein, which are important events in prion disease, and how they are modulated by conformational conversion. Native (N) mouse prion protein (moPrP) is known to form small (OS) and large (OL) oligomers rich in {beta}-sheet, and in this study, photoinduced electron transfer-fluorescence correlation spectroscopy (PET-FCS) has been used to characterize intramolecular dynamics within individual monomeric units in both isolated OS and OL, as well as the diffusion properties of the oligomers. It is estimated that OS and OL comprise of about 15 and 55 monomeric units, respectively. Microsecond dynamics at each of the two regions that are the 1-3 and 2-3 interfaces of native protein are distinct in N, OS and OL, although they occur on very similar timescales. Analysis of the evolution of the distribution of diffusion times, determined using the maximum entropy method, indicates heterogeneity in the oligomerization reaction. Analysis of the change in the fluctuations which occur in two different timescales in the native state ensemble shows that they are damped more at the erstwhile 1-3 interface than the erstwhile 2-3 interface. The difference in the extent of damping at the erstwhile 1-3 and 2-3 interfaces can be explained on the basis of the structural changes known to occur across each region. The changes in dynamics occur concurrently in both regions, indicating that the structural changes accompanying conformational conversion also occur simultaneously during the oligomerization of moPrP.

biophysics↗