bioRxiv Science⌕ Search

bioRxiv · 10.64898/2026.06.04.730070

Comparing Machine Learning Approaches for Predicting CFD-Derived Stroke Risk Indicators in Atrial Fibrillation Patients

Abstract

Non-valvular atrial fibrillation (AF) is associated with a five-fold increased risk of stroke, mainly due to impaired contractility of the left atrium (LA) leading to blood stasis and subsequent thrombus formation within the left atrial appendage (LAA). Current AF stroke risk stratification schemes, such as the CHA2DS2-VASc/ CHA2DS2-VA score, use comorbidities and do not capture mechanistic factors like blood flow dynamics and hypercoagulability. To address this, we developed a multiphase computational fluid dynamics (CFD) model of the LA, incorporating patient-specific geometries; modelling of the coagulation cascade; and non-Newtonian blood behaviour within the LAA. Using 84 simulation cases generated via Latin Hypercube Sampling of physiological blood parameters and 21 patient-derived LA anatomies, we trained surrogate machine learning models, including Ridge regression, XGBoost, Gaussian Process Emulators (GPEs), and deep learning networks, to predict CFD outputs such as blood viscosity in and fibrin concentrations in the LAA. Deep learning achieved R{superscript 2} values up to 0.90, with the accuracy increasing when both physiological parameters and the raw CT image were included. Other models showed uneven performance with R2 values below 0.7, highlighting the role of nonlinearities between parameters. The study presents a novel CFD model that captures the transition from blood stasis to clot formation, representing the full thrombotic continuum underlying stroke risk in AF, and a deep learning approach to enable efficient prediction of mechanistic outputs of clinical value for stroke risk stratification in AF patients. Author SummaryAtrial fibrillation is a common heart rhythm disorder that greatly increases the risk of stroke. In many patients, blood can pool inside a small pouch of the heart called the left atrial appendage, where clots may form and later travel to the brain. Current clinical tools used to estimate stroke risk mainly rely on a patients medical history and do not directly assess the mechanistic processes that lead to clot formation. In this study, we developed a computer model that simulates how blood flows and clots inside the heart using patient-specific heart anatomies derived from medical imaging. Our model combines blood flow, blood biochemistry, and the changing physical properties of blood during clot formation. We then used machine learning methods to predict these complex simulation results more efficiently. Deep learning models performed best, particularly when both clinical parameters and heart imaging data were included. Our work provides a new way to study the full process linking abnormal blood flow to clot formation in atrial fibrillation. In the future, this approach could support more personalised and mechanistic assessment of stroke risk and help guide treatment decisions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Melidoro, P., Cavarra, R., Mostafa, S., Lip, G. Y. H., Klis, M., Williams, S. E., Aslanidi, O., De Vecchi, A.. 2026-06-08. Comparing Machine Learning Approaches for Predicting CFD-Derived Stroke Risk Indicators in Atrial Fibrillation Patients. https://doi.org/10.64898/2026.06.04.730070

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Wall stiffening is a primary contributor to motility loss in Crohn's disease: an electromechanical modeling study

Fibrotic strictures are among the most disabling complications of Crohn's disease, permanently narrowing the bowel and impairing motility, yet no approved therapy reverses them. Chronic inflammation alters pacemaker-network coupling, smooth-muscle excitability, and calcium-dependent contractility, while fibrosis thickens the bowel wall, narrows the lumen, and changes tissue mechanics. The relative contributions of these coupled electrical, contractile, and structural alterations to motility loss remain unclear. To address this gap, we develop an integrated electromechanical finite-element framework for fibrostenosing Crohn's disease that couples a fibrosis-driven growth model with a FitzHugh-Nagumo electromechanical model. A full-factorial 25 design of experiments is used to quantify the relative effects of electrical diffusivity, excitation threshold, peak active stress, wall stiffness, and hypertrophic remodeling on cyclic lumen-volume deformation. Motility is quantified by the standard deviation of lumen volume over one contraction cycle. Within the parameter ranges examined, increased wall stiffness emerged as the dominant contributor to motility loss, followed by impaired smooth-muscle contractility. Changes in excitation threshold, hypertrophic remodeling, and electrical diffusivity produced substantially smaller effects. Pairwise interactions were small relative to the dominant main effects, indicating that the mechanisms contributed largely through their individual effects. Our findings suggest that limiting wall stiffening while preserving smooth-muscle contractile function may provide a therapeutic strategy for maintaining intestinal motility in fibrostenosing Crohn's disease.

bioengineering↗

Lactate Receptor Activation Alleviates Senescence and Preserves Homeostasis of Aged Arteries

Arteries are among the first tissues to exhibit age-related dysfunction, yet the metabolic mechanisms driving vascular senescence remain poorly understood. Here, analysis of human aortic transcriptomic data identified HCAR1, encoding the lactate receptor GPR81, as one of the genes most significantly downregulated with age. We therefore investigated whether age-associated loss of GPR81 contributes to cellular senescence within the vessel wall. Senescent human endothelial cells and vascular smooth muscle cells accumulated neutral and oxidized lipids and exhibited increased labile iron and ferroptosis. Silencing GPR81 in early-passage cells recapitulated this metabolic phenotype together with multiple hallmarks of cellular senescence. Moreover, endothelial-specific deletion of GPR81 in young mice was sufficient to induce senescent cell accumulation, impaired lipid homeostasis, endothelial dysfunction, and elastin disorganization. Conversely, pharmacological activation of GPR81 with the agonist CHBA restored fatty acid metabolism, promoted glycolytic reprogramming, and attenuated ferroptotic stress and senescence-associated phenotypes. In lamin A knock-in (LAKI) progeroid mice, CHBA reduced arterial lipid accumulation and cellular senescence, shifted vascular cell composition toward a youthful state, improved endothelial integrity, and restored extracellular matrix homeostasis. Together, these findings identify age-associated loss of GPR81 as a driver of vascular metabolic dysfunction and cellular senescence and establish pharmacological GPR81 activation as a promising therapeutic strategy for preserving vascular homeostasis and mitigating age-associated cardiovascular disease.

bioengineering↗

Targeted and bilateral blood flow monitoring in middle cerebral artery using diffuse correlation spectroscopy

Objective: To develop and validate a dual-probe Diffuse Correlation Spectroscopy (DCS) system for non-invasive and simultaneous, monitoring of cerebral blood flow (CBF) in the bilateral Middle Cerebral Artery (MCA) territories, and expanding the utility of conventional DCS limited to cortical-volume-based CBF measurements to vessel-specific cerebral perfusion monitoring. Methods: A dual-probe DCS system was designed for non-invasive monitoring of MCA-specific perfusion. Probe placement and protocol optimization study has been performed using anatomical landmarks, motor and speech activation tasks in healthy volunteers. System stability and repeatability were further evaluated in a pilot cohort of 30 healthy (age, 25{+/-}7 years) participants using optimized probe position and protocol. A bilateral MCA ischemic Lacunar Infract stroke case report also validated the feasibility of the system in clinical settings. Results: Measurements demonstrated superior sensitivity towards MCA-territory perfusion at targeted probe locations compared to off-MCA positions. In pilot cohort, significant increase of 30.34 {+/-} 21.56% and 36.48 {+/-} 21.22% in rCBF corresponding to hand squeeze and speech task respectively showed reproducible physiological responsiveness of the system (p<0.001). Measurement done on a patient with bilateral MCA ischemic Lacunar Infract stroke showed a significant change of 30% during speech for both the MCAs but no significant change is observed for hand squeeze tasks. Conclusion: The custom built dual-probe DCS system enables non-invasive, operator-independent, targeted and continuous monitoring of rCBF within bilateral MCA territories. Significance: This approach enables the potential use of DCS system for bilateral and vessel-specific monitoring of cerebral perfusion in the MCA territories.

bioengineering↗