bioRxiv Science⌕ Search

bioRxiv · 10.64898/2026.04.24.717780

Evaluation of Diffusion Tensor Imaging in the Corpus Callosum on a Portable 100 mT MRI System

Abstract

Low-cost portable MRI has the potential to improve the accessibility of MRI, but new acquisition methods and protocols must be developed and evaluated to accommodate the reduction in SNR and greater impact of system imperfections. Diffusion tensor imaging (DTI) is a candidate tool for monitoring population health, but the bias and variance of quantitative diffusion tensor-derived metrics must be evaluated prior to designing such studies. DTI of the corpus callosum was performed on an in-house, portable 100 mT MRI system using a slab diffusion weighted Fast Spin Echo with radiofrequency (RF) encoding. Slice coverage was restricted to the corpus callosum to shorten scan time and reduce sensitivity to large rigid motion. In vivo DTI images were obtained in two healthy volunteers with nominal voxel size 50 mm3, scan time 25 minutes, and two different volunteers using nominal voxel size 25 mm3, scan time 35 minutes. Mean diffusivity (MD) and fractional anisotropy (FA) coefficients of variation were estimated in the 50 mm3 acquisition using a bootstrap approach and compared to resolution-matched data obtained on a conventional 1.5T system. MD / FA maps were compared quantitatively and qualitatively. Mean MD values in the corpus callosum obtained on the 100 mT system were within 10% of the reference 1.5T acquisition, but FAs were underestimated by 20-30%. The corpus callosum median MD coefficient of variation was 3.7%, and the median FA coefficient of variation was 7.5%. FA maps obtained at 100 mT had an elevated FA noise floor and color FA maps had lower apparent resolution but some white matter tracts were still distinguishable. HighlightsO_LIDiffusion Tensor Imaging (DTI) of the corpus callosum was performed on a portable 100 mT MRI scanner with 50 mm3 voxels in 25 minutes scan time. C_LIO_LIMean Diffusivity estimates in the corpus callosum obtained at 100 mT and 1.5T differed by less than 0.1 x 10-3 mm2/s. C_LIO_LISome white matter tracts were visible in color Fractional Anisotropy maps obtained at 100 mT but FA maps were underestimated by 20- 30% when compared to a resolution-matched 1.5T acquisition, and had lower apparent resolution. C_LI

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Lee, P. K., Chen, S., Zhong, S., Wang, C., Zhang, Z.. 2026-04-28. Evaluation of Diffusion Tensor Imaging in the Corpus Callosum on a Portable 100 mT MRI System. https://doi.org/10.64898/2026.04.24.717780

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Wall stiffening is a primary contributor to motility loss in Crohn's disease: an electromechanical modeling study

Fibrotic strictures are among the most disabling complications of Crohn's disease, permanently narrowing the bowel and impairing motility, yet no approved therapy reverses them. Chronic inflammation alters pacemaker-network coupling, smooth-muscle excitability, and calcium-dependent contractility, while fibrosis thickens the bowel wall, narrows the lumen, and changes tissue mechanics. The relative contributions of these coupled electrical, contractile, and structural alterations to motility loss remain unclear. To address this gap, we develop an integrated electromechanical finite-element framework for fibrostenosing Crohn's disease that couples a fibrosis-driven growth model with a FitzHugh-Nagumo electromechanical model. A full-factorial 25 design of experiments is used to quantify the relative effects of electrical diffusivity, excitation threshold, peak active stress, wall stiffness, and hypertrophic remodeling on cyclic lumen-volume deformation. Motility is quantified by the standard deviation of lumen volume over one contraction cycle. Within the parameter ranges examined, increased wall stiffness emerged as the dominant contributor to motility loss, followed by impaired smooth-muscle contractility. Changes in excitation threshold, hypertrophic remodeling, and electrical diffusivity produced substantially smaller effects. Pairwise interactions were small relative to the dominant main effects, indicating that the mechanisms contributed largely through their individual effects. Our findings suggest that limiting wall stiffening while preserving smooth-muscle contractile function may provide a therapeutic strategy for maintaining intestinal motility in fibrostenosing Crohn's disease.

bioengineering↗

Lactate Receptor Activation Alleviates Senescence and Preserves Homeostasis of Aged Arteries

Arteries are among the first tissues to exhibit age-related dysfunction, yet the metabolic mechanisms driving vascular senescence remain poorly understood. Here, analysis of human aortic transcriptomic data identified HCAR1, encoding the lactate receptor GPR81, as one of the genes most significantly downregulated with age. We therefore investigated whether age-associated loss of GPR81 contributes to cellular senescence within the vessel wall. Senescent human endothelial cells and vascular smooth muscle cells accumulated neutral and oxidized lipids and exhibited increased labile iron and ferroptosis. Silencing GPR81 in early-passage cells recapitulated this metabolic phenotype together with multiple hallmarks of cellular senescence. Moreover, endothelial-specific deletion of GPR81 in young mice was sufficient to induce senescent cell accumulation, impaired lipid homeostasis, endothelial dysfunction, and elastin disorganization. Conversely, pharmacological activation of GPR81 with the agonist CHBA restored fatty acid metabolism, promoted glycolytic reprogramming, and attenuated ferroptotic stress and senescence-associated phenotypes. In lamin A knock-in (LAKI) progeroid mice, CHBA reduced arterial lipid accumulation and cellular senescence, shifted vascular cell composition toward a youthful state, improved endothelial integrity, and restored extracellular matrix homeostasis. Together, these findings identify age-associated loss of GPR81 as a driver of vascular metabolic dysfunction and cellular senescence and establish pharmacological GPR81 activation as a promising therapeutic strategy for preserving vascular homeostasis and mitigating age-associated cardiovascular disease.

bioengineering↗

Targeted and bilateral blood flow monitoring in middle cerebral artery using diffuse correlation spectroscopy

Objective: To develop and validate a dual-probe Diffuse Correlation Spectroscopy (DCS) system for non-invasive and simultaneous, monitoring of cerebral blood flow (CBF) in the bilateral Middle Cerebral Artery (MCA) territories, and expanding the utility of conventional DCS limited to cortical-volume-based CBF measurements to vessel-specific cerebral perfusion monitoring. Methods: A dual-probe DCS system was designed for non-invasive monitoring of MCA-specific perfusion. Probe placement and protocol optimization study has been performed using anatomical landmarks, motor and speech activation tasks in healthy volunteers. System stability and repeatability were further evaluated in a pilot cohort of 30 healthy (age, 25{+/-}7 years) participants using optimized probe position and protocol. A bilateral MCA ischemic Lacunar Infract stroke case report also validated the feasibility of the system in clinical settings. Results: Measurements demonstrated superior sensitivity towards MCA-territory perfusion at targeted probe locations compared to off-MCA positions. In pilot cohort, significant increase of 30.34 {+/-} 21.56% and 36.48 {+/-} 21.22% in rCBF corresponding to hand squeeze and speech task respectively showed reproducible physiological responsiveness of the system (p<0.001). Measurement done on a patient with bilateral MCA ischemic Lacunar Infract stroke showed a significant change of 30% during speech for both the MCAs but no significant change is observed for hand squeeze tasks. Conclusion: The custom built dual-probe DCS system enables non-invasive, operator-independent, targeted and continuous monitoring of rCBF within bilateral MCA territories. Significance: This approach enables the potential use of DCS system for bilateral and vessel-specific monitoring of cerebral perfusion in the MCA territories.

bioengineering↗