bioRxiv Science⌕ Search

bioRxiv · 10.64898/2026.02.04.703920

Modelling Medial Degenerative Features by Enzymatic Digestion to Evaluate Disease-Relevant Structure-Function Relationships in the Thoracic Aorta

Abstract

BackgroundAortic microstructure-function relationships and the pathophysiology of how medial degeneration leads to aortic dissection remain poorly defined. We aimed to determine how degeneration of individual components of the extracellular matrix (ECM), namely elastin, collagen, and proteoglycans, influence biomechanical properties of aortic tissue through an improved, disease-motivated enzymatic digestion framework. MethodsPorcine aortic tissue was sectioned into 200 {micro}m thick samples in the media, and progressively digested with elastase or collagenase for selective degradation of these ECM components. Full thickness human aortic tissues were treated with chondroitinase, hyaluronidase, and heparinase to completely remove proteoglycans. Biomechanical characterization was performed using planar biaxial tensile testing, from which low- and high-strain modulus, transition-zone behaviour, strain-energy density, and energy loss were derived. Degree of elastin fiber degradation was analyzed using two photon excitation fluorescence imaging. Analysis of collagen degradation was performed using picrosirius red staining under brightfield and polarized light. Alcian blue staining was used to evaluate proteoglycan content. ResultsInduced fragmentation and disorganization of elastin fibers reduced low-strain load bearing capacity, evidenced by reduced low-strain modulus, strain-energy density, and transition zone stress, along with reduced energy loss. Targeted collagen disorganization similarly reduced strain-energy density and decreased strain at the onset of transition, consistent with premature collagen recruitment, and was accompanied by reductions in high strain modulus and energy loss with increasing collagen degradation. Proteoglycan removal decreased energy loss and was found to modulate low- and high-strain behaviour, including reduced strain-energy density and strain at onset of transition, and increased high strain modulus. ConclusionsThrough targeted modelling of ECM degenerative features on aortic tissue mechanics, we have identified distinct disease-associated biomechanical roles for major matrix constituents, with overlapping effects. These findings delineate mechanical consequences of component-specific matrix degeneration while underscoring the complex, multifactorial nature of structure-function relationships in aortic disease.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Eliathamby, D., Ung, L., Yap, H., Elbatarny, M., Ouzounian, M., Bendeck, M. P., Seidman, M. A., Simmons, C. A., Chung, J. C.-Y.. 2026-02-09. Modelling Medial Degenerative Features by Enzymatic Digestion to Evaluate Disease-Relevant Structure-Function Relationships in the Thoracic Aorta. https://doi.org/10.64898/2026.02.04.703920

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Synergy-informed bilevel optimization reveals joint-specific benefits for realistic exoskeleton torque prediction

Simulation-driven optimization can guide exoskeleton control design, but its utility is limited by the accuracy with which muscle coordination is predicted. Strict effort-minimization formulations predict non-physiological muscle shutdown under high exoskeleton assistance, leading to peak assistive torques that exceed values reported in human-in-the-loop experiments. We evaluated the accuracy of synergy-informed simulations at predicting assistance across four single-joint exoskeleton configurations: ankle plantarflexion, knee extension, hip flexion, and hip abduction. We implemented a bilevel optimization to predict a parameterized assistive torque that minimizes metabolic cost, with assisted muscle dynamics estimated via either effort-minimization simulations (minimizing muscle effort only) or synergy-informed simulations (minimizing muscle effort constrained to a synergy structure). We used experimental data from five unimpaired adults walking at their preferred speed and compared results descriptively between the two formulations within each subject. Assistance based on effort-minimization simulations shut down agonist muscle activations and overestimated peak assistive torque compared with experimental values. In contrast, constraining muscle controls to a synergy structure prevented non-physiological muscle shutdown and yielded assistive torques closer to those measured in human-in-the-loop experiments. This benefit was not observed equally across all assisted degrees of freedom or subjects, emerging only where no single synergy could be suppressed to unload the assisted muscles. Synergy weights can therefore be interpreted as joint-specific predictors of when simulations can reliably inform wearable robot design.

bioengineering↗

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗