bioRxiv Science⌕ Search

bioRxiv · 10.64898/2026.01.09.698654

Task-Specific Computational Fluid Dynamics Evaluation of Multi-Outlet Extrusion Nozzles for Bioprinting

Abstract

Extrusion bioprinting is moving from proof-of-concept demonstrations toward repeatable, manufacturing-style workflows, but the nozzle remains a persistent bottleneck. Inside compact, opaque channels, bioinks experience strong geometric forcing that sets the local shear environment for cells, the pressure demand on the printer, and the uniformity of deposition. Multi-outlet nozzles are attractive because they promise higher throughput by splitting one feed into parallel filaments, yet in practice they often suffer from uneven outlet delivery and junction-driven shear hotspots. As a result, nozzle selection and scaling are still largely guided by trial-and-error rather than quantitative design evidence. In this work we provide a controlled, task-oriented comparison of two novel multi-outlet splitter archetypes-- a compact radial 90{degrees} manifold and a branched Y-split--implemented with two and four outlets. Using three-dimensional computational fluid dynamics with representative rheology for three common hydrogel bioinks (GelMA, MeHA, and alginate) under typical pneumatic actuation, we resolve internal pressure, velocity, and wall shear stress fields and translate them into practical decision metrics for outlet balance and pressure-normalised throughput. The results show that the two-outlet 90{degrees} manifold is the most robust "default" geometry, consistently delivering the most uniform outlet splitting for shear-thinning inks while maintaining the most conservative shear footprint, making it the safest option for cell-laden and precision printing. The two-outlet Y-split achieves higher outlet speeds and is therefore better suited to fast deposition of acellular or support materials, but it concentrates elevated shear at the primary junction and is more sensitive to operating regime for weakly shear-dependent inks. Scaling from two to four outlets markedly increases the risk of maldistribution across all materials and pressures, and does not eliminate junction-anchored shear hotspots in the Y-split, indicating that passive geometric symmetry is insufficient at higher outlet counts. Overall, this study converts an informal design choice into evidence-based nozzle selection rules, enabling practitioners to match nozzle architecture to printing task (cell safety, precision, or throughput) and to anticipate when multi-outlet scaling will require active balancing or flow control. The proposed framework accelerates nozzle development, improves print reproducibility, and helps define safer operating windows for bioprinting with living cells.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Vargas Urdaneta, C. D., Barros, M. T.. 2026-01-10. Task-Specific Computational Fluid Dynamics Evaluation of Multi-Outlet Extrusion Nozzles for Bioprinting. https://doi.org/10.64898/2026.01.09.698654

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Wall stiffening is a primary contributor to motility loss in Crohn's disease: an electromechanical modeling study

Fibrotic strictures are among the most disabling complications of Crohn's disease, permanently narrowing the bowel and impairing motility, yet no approved therapy reverses them. Chronic inflammation alters pacemaker-network coupling, smooth-muscle excitability, and calcium-dependent contractility, while fibrosis thickens the bowel wall, narrows the lumen, and changes tissue mechanics. The relative contributions of these coupled electrical, contractile, and structural alterations to motility loss remain unclear. To address this gap, we develop an integrated electromechanical finite-element framework for fibrostenosing Crohn's disease that couples a fibrosis-driven growth model with a FitzHugh-Nagumo electromechanical model. A full-factorial 25 design of experiments is used to quantify the relative effects of electrical diffusivity, excitation threshold, peak active stress, wall stiffness, and hypertrophic remodeling on cyclic lumen-volume deformation. Motility is quantified by the standard deviation of lumen volume over one contraction cycle. Within the parameter ranges examined, increased wall stiffness emerged as the dominant contributor to motility loss, followed by impaired smooth-muscle contractility. Changes in excitation threshold, hypertrophic remodeling, and electrical diffusivity produced substantially smaller effects. Pairwise interactions were small relative to the dominant main effects, indicating that the mechanisms contributed largely through their individual effects. Our findings suggest that limiting wall stiffening while preserving smooth-muscle contractile function may provide a therapeutic strategy for maintaining intestinal motility in fibrostenosing Crohn's disease.

bioengineering↗

Lactate Receptor Activation Alleviates Senescence and Preserves Homeostasis of Aged Arteries

Arteries are among the first tissues to exhibit age-related dysfunction, yet the metabolic mechanisms driving vascular senescence remain poorly understood. Here, analysis of human aortic transcriptomic data identified HCAR1, encoding the lactate receptor GPR81, as one of the genes most significantly downregulated with age. We therefore investigated whether age-associated loss of GPR81 contributes to cellular senescence within the vessel wall. Senescent human endothelial cells and vascular smooth muscle cells accumulated neutral and oxidized lipids and exhibited increased labile iron and ferroptosis. Silencing GPR81 in early-passage cells recapitulated this metabolic phenotype together with multiple hallmarks of cellular senescence. Moreover, endothelial-specific deletion of GPR81 in young mice was sufficient to induce senescent cell accumulation, impaired lipid homeostasis, endothelial dysfunction, and elastin disorganization. Conversely, pharmacological activation of GPR81 with the agonist CHBA restored fatty acid metabolism, promoted glycolytic reprogramming, and attenuated ferroptotic stress and senescence-associated phenotypes. In lamin A knock-in (LAKI) progeroid mice, CHBA reduced arterial lipid accumulation and cellular senescence, shifted vascular cell composition toward a youthful state, improved endothelial integrity, and restored extracellular matrix homeostasis. Together, these findings identify age-associated loss of GPR81 as a driver of vascular metabolic dysfunction and cellular senescence and establish pharmacological GPR81 activation as a promising therapeutic strategy for preserving vascular homeostasis and mitigating age-associated cardiovascular disease.

bioengineering↗

Targeted and bilateral blood flow monitoring in middle cerebral artery using diffuse correlation spectroscopy

Objective: To develop and validate a dual-probe Diffuse Correlation Spectroscopy (DCS) system for non-invasive and simultaneous, monitoring of cerebral blood flow (CBF) in the bilateral Middle Cerebral Artery (MCA) territories, and expanding the utility of conventional DCS limited to cortical-volume-based CBF measurements to vessel-specific cerebral perfusion monitoring. Methods: A dual-probe DCS system was designed for non-invasive monitoring of MCA-specific perfusion. Probe placement and protocol optimization study has been performed using anatomical landmarks, motor and speech activation tasks in healthy volunteers. System stability and repeatability were further evaluated in a pilot cohort of 30 healthy (age, 25{+/-}7 years) participants using optimized probe position and protocol. A bilateral MCA ischemic Lacunar Infract stroke case report also validated the feasibility of the system in clinical settings. Results: Measurements demonstrated superior sensitivity towards MCA-territory perfusion at targeted probe locations compared to off-MCA positions. In pilot cohort, significant increase of 30.34 {+/-} 21.56% and 36.48 {+/-} 21.22% in rCBF corresponding to hand squeeze and speech task respectively showed reproducible physiological responsiveness of the system (p<0.001). Measurement done on a patient with bilateral MCA ischemic Lacunar Infract stroke showed a significant change of 30% during speech for both the MCAs but no significant change is observed for hand squeeze tasks. Conclusion: The custom built dual-probe DCS system enables non-invasive, operator-independent, targeted and continuous monitoring of rCBF within bilateral MCA territories. Significance: This approach enables the potential use of DCS system for bilateral and vessel-specific monitoring of cerebral perfusion in the MCA territories.

bioengineering↗