Reconstruction of Average Subtracted Tubular Regions (RASTR) Enables Structure Determination of Tubular Filaments by Cryo-EM
Abstract
As the field of electron microscopy moves forward, the increasing complexity of samples being produced demand more involved processing methods. In this study, we have developed a new processing method for generating 3D reconstructions of tubular structures. Tubular biomolecules are common throughout many cellular processes and are appealing targets for a variety of biophysical research. Processing of tubules with helical symmetry is relatively straightforward for electron microscopy if the helical parameters are known, but tubular structures that deviate from helical symmetry (asymmetrical components, local but no global order, etc) present myriad issues. Here we present a new processing technique called Reconstruction of Average Subtracted Tubular Regions (RASTR), which was developed to reconstruct tubular structures without applying symmetry. We explain the RASTR approach and quantify its performance using three examples: a simulated symmetrical tubular filament, a symmetrical tubular filament from cryo-EM data, and a membrane tubule coated with locally ordered but not globally ordered proteins.
Source connections
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Randolph, P. S., Stagg, S. M.. 2019-09-18. Reconstruction of Average Subtracted Tubular Regions (RASTR) Enables Structure Determination of Tubular Filaments by Cryo-EM. https://doi.org/10.1101/774802