bioRxiv Science⌕ Search

bioRxiv · 10.1101/762716

A modular microreservoir for active implantable drug delivery

Abstract

Active implantable microscale reservoir-based drug delivery systems enabled novel and effective drug delivery concepts for both systemic and localized drug delivery applications. These systems typically consist of a drug reservoir and an active pumping mechanism for precise delivery of drugs. Here we present a stand-alone, refillable, scalable, and fully implantable microreservoir platform to be integrated with micropumps as a storing component of active implantable drug delivery microsystems. The microreservoir was fabricated with 3D-printing technology, enabling miniature, scalable, and planar structure, optimized for subcutaneous implantation especially in small animals (e.g., mouse), while being readily scalable for larger animals and human translation. Three different capacities of the microreservoir (1 L, 10 L, and 100 L) were fabricated and characterized all with 3 mm thickness. The microreservoir consists of two main parts: a cavity for long-term drug storage with an outlet microtubing (250 m OD, 125 m ID), and a refill port for transcutaneous refills through a septum. The cavity membrane is fabricated with thin Parylene-C layers using a polyethylene glycol sacrificial layer, minimizing restoring force and hence backflow, as fluid is discharged. This feature enables integration to normally-open mechanisms and improves pumping efficiency when integrated to normally-closed pumps. The results of in vitro optimization and characterization of the cavity membrane show 95% extraction percentage of the cavity with insignificant (2%) backflow due to restoring force of the membrane. The refill port septum thickness is minimized down to 1 mm by a novel pre-compression concept, while capable of ~65000 injections with 30 Ga non-coring needles without leakage under 100 kPa (4x greater than physiological backpressure). To demonstrate integrability of the microreservoir to an active micropump, the 10 L microreservoir was integrated to a micropump recently developed in our laboratory, making an implantable drug delivery microsystem. Two different microsystems were subcutaneously implanted in two mice, and the outlet microtubing was implanted into the round window membrane niche for infusion of a known ototoxic compound (sodium salicylate) at 50 nL/min for 20 min. Real-time shifts in distortion product otoacoustic emission thresholds and amplitudes were measured during the infusion. The in vivo results show a mean shift of 22.1 dB after 20 min for the most basal region, matching with syringe pump results. A biocompatibility experiment was performed on the microsystem for six months to assess design and fabrication suitability for chronic subcutaneous implantation and clinical translational development. The results demonstrate very favorable signs of biocompatibility for long-term implantation. Although tested here on mice for a specific inner ear application, this low-cost design and fabrication methodology is scalable for use in larger animals and human for different applications/delivery sites.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Forouzandeh, F., Zhu, X., Ahamed, N. N., Walton, J. P., Frisina, R. D., Borkholder, D. A.. 2019-09-12. A modular microreservoir for active implantable drug delivery. https://doi.org/10.1101/762716

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗

PROST: An Open Toolbox, Harmonised Multi-Lab Dataset, and Meta-Analysis of Ankle-Foot Roll-Over Shape

The ankle-foot roll-over shape (ROS) is the sagittal-plane path of the centre of pressure (CoP) during the stance phase of walking, expressed in a shank-based coordinate system. It describes the effective rocker geometry that emerges from both the shape and the elastic deformation of the ankle-foot system during walking, and informs prosthetic and orthotic design. Previous studies characterised ROS in small samples with differing laboratory protocols, so they have not systematically assessed inter-individual variability or its relation to anthropometrics. We developed the open-source Public ROS Toolbox (PROST) for standardised ROS computation, and used it to harmonise marker trajectories, ground reaction forces and CoP data from four public gait datasets collected in independent laboratories. For each leg, we fitted a circular arc to the pooled ROS of all its stance phases. In a one-stage individual-participant data meta-analysis, linear mixed-effects models, with dataset as a fixed effect and participant as a random intercept, related the arc radius and the horizontal coordinate of the circle centre to anthropometrics, and, in the two self-selected-speed datasets, to walking speed. The harmonised dataset comprises 249 participants and 5,667 stance phases at walking speeds of 0.7-8.5 km/h. Circular arcs fitted the ROS closely (mean RMS radial residual 1.9 mm). The radius had a median of 410.3 mm (interquartile range, IQR, 237.6 mm), and the circle centre lay posterior to the ankle (median -20.6 mm, IQR 49.5 mm). Between-participant differences, quantified by the intraclass correlation coefficient (ICC), accounted for 42% of the variance in log radius (95% CI 25-57%) and 47% of the variance in the horizontal coordinate of the circle centre (95% CI 24-65%). Anthropometrics explained a negligible share of this variance (radius: pseudo-R2 -0.001, 95% CI -0.03 to 0.12), and height normalisation did not reduce radius variability (robust coefficient of variation 43% with and without normalisation). Faster self-selected walking was associated with a larger radius and a more posterior circle centre. To our knowledge, this study provides the first harmonised multi-lab ROS dataset. Together with the open-source toolbox, it is publicly available to support reproducible research in gait biomechanics, rehabilitation device design and clinical gait assessment. ROS geometry was participant-specific but was not predicted by age, sex, height or mass. A device ROS scaled from anthropometrics is therefore unlikely to match an individual's ROS, motivating studies of whether matching it, through device geometry and stiffness, improves gait mechanics.

bioengineering↗