Accuracy of different modalities of reaction time testing: Implications for online cognitive assessment tools.

Abstract

Reaction time testing is widely used in computerized cognitive assessments, and clinical studies have repeatedly shown it to be a sensitive indicator of cognitive function. Typically, the reaction time test is administered by presenting a subject with a visual stimulus on a computer monitor and prompting the individual to respond (via keypad or computer mouse) as quickly as possible. The individuals reaction time is calculated as the interval between presentation of the stimulus and the time recorded from the mechanical response. However, there are many inherent latencies and variabilities that may be introduced to the measure by both hardware (computer monitor and mouse) and software (operating system). Because of these delays, we hypothesized that a comparison of hardware protocols (excluding human response) would demonstrate significant differences in the resulting reaction time measures. To simulate the delays of various components of the common systems used to obtain reaction time, we conducted a simple experiment in which either a visual or tactile stimulus evoked a movement from a mechanical transducer to respond to a computer peripheral or a dedicated response device. In the first condition, a simulated visual reaction time test was conducted by flashing a visual stimulus on a computer monitor. The stimulus was detected by a dedicated light sensor, and a linear actuator delivered the mechanical response via computer mouse. The second test condition employed a mobile device as the medium for the visual stimulus, and the mechanical response was delivered to the mobile devices touchscreen. The third and fourth test conditions simulated tactile reaction time tests in which the stimulus was generated by a dedicated hardware device. The third condition simulated a tactile stimulus, which was detected by a mechanical switch, and again a hardware device delivered the response via computer mouse. The fourth condition also simulated a tactile stimulus, but the response was delivered by a dedicated hardware device designed to store the interval between stimulus delivery and stimulus response. There were significant differences in the range of responses recorded from the four different conditions with the reaction time collected from a visual stimulus on a mobile device being the worst and the device with dedicated hardware designed for the task being the best. The results suggest that some of the commonly used visual tasks on consumer grade computers could be introducing significant errors for reaction time testing and that dedicated hardware designed for the reaction time task is needed to minimize testing errors.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Holden, J., Francisco, E., Lensch, R., Tommerdahl, A., Kirsch, B., Zai, L., Dennis, R., Tommerdahl, M.. 2019-08-06. Accuracy of different modalities of reaction time testing: Implications for online cognitive assessment tools.. https://doi.org/10.1101/726364

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering