bioRxiv Science⌕ Search

bioRxiv · 10.1101/695833

Neck Musculoskeletal Model Generation through Anthropometric Scaling

Abstract

A new methodology was developed to quickly generate whole body models with detailed neck musculoskeletal architecture that are properly scaled in terms of anthropometry and muscle strength. This method was implemented in an anthropometry model generation software that allows users to interactively generate any new male or female musculoskeletal models with adjustment of anthropometric parameters (such as height, weight, neck circumference, and neck length) without the need of subject-specific motion capture or medical images. 50th percentile male and female models were developed based on the 2012 US Army Anthropometric Survey (ANSUR II) database and optimized with a novel bilevel optimization method to have strengths comparable to experimentally measured values in the literature. Other percentile models (ranging from the 1st to 99th percentile) were generated based on anthropometric scaling of the 50th percentile models and compared. The resultant models are reasonably accurate in terms of both musculoskeletal geometry and neck strength, demonstrating the effectiveness of the developed methodology for interactive neck model generation with anthropometric scaling.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Roos, P. E., Vasavada, A., Zheng, L., Zhou, X.. 2019-07-08. Neck Musculoskeletal Model Generation through Anthropometric Scaling. https://doi.org/10.1101/695833

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Material-driven fibronectin assembly enables low-dose BMP-2 to regenerate structurally mature bone in critical-sized load-bearing defects

Bone grafts for critical-sized load-bearing defects are usually judged by how much bone forms, and rarely by whether that bone is structurally and mechanically competent. Here, degradable ceramic monetites coated with poly(ethyl acrylate) (PEA) and functionalised with fibronectin (FN) and rhBMP-2 at 10-25 g/mL, 60-150-fold below the approved clinical concentration, are assessed across length scales. MicroCT showed that only monetites functionalised with rhBMP-2 bridged the defect, with a significant increase in new bone volume in both the monetite vicinity and the whole defect volume. In contrast, platelet-rich plasma (PRP) functionalisation significantly reduced bone formation relative to FN, showing that the identity of the adhesion cue, and not merely its presence, determines the outcome. Monetite degradation and increased interconnected porosity favoured bone ingrowth and produced a continuous interface between monetite and new bone. The multiscale analyses of quantitative polarised light microscopy, SAXS and nanoindentation show that PEA-coated monetites functionalised with FN and 25 g/mL rhBMP-2 promoted structurally and mechanically more mature bone, with a hierarchical organisation and local mechanical properties approaching those of native cortical tissue. In the bridged region this group recapitulated the preferential collagen fibre orientation of native cortical bone and reached an elastic modulus and hardness that were not statistically distinguishable from it, although mineral particles throughout the regenerated tissue remained thicker and less aligned than in cortical bone. Synchrotron microCT in an ovine model extended these findings to a clinically relevant scale, supporting the translational potential of the system. Taken together, these findings position PEA-coated monetites functionalised with FN and low-dose rhBMP-2 as a strategy for the structural and functional regeneration of large bone defects.

bioengineering↗

N-GLYcanyzer monitoring of a microperfusion process reveals critical parameters' impact on Trastuzumab biosimilar N-glycoform time evolution

Controlling monoclonal antibody (mAb) N-glycosylation as a critical quality attribute (CQA) remains challenging in continuous and intensified biomanufacturing, where conventional end-point analyses obscure dynamic pathway responses. Here, we deployed the N-GLYcanyzer process analytical technology (PAT) for automated monitoring of a microperfusion process that reveals critical parameters' impact on Trastuzumab biosimilar N-glycoform time evolution across a 20-day culture duration of Chinese Hamster Ovary (CHO) cells in a ~2 mL scale-down microbioreactor perfusion platform. Using offline PAT assays combined with our integrated at-line PAT workflow, we systematically screened six perfusion process parameters: carbon source, viable cell density (VCD), perfusion rate, temperature, and pH. While nutrient limitation and thermal/acidic stress significantly disrupted N-glycans maturation, notably triggering high-mannose (Man5) accumulation and severe productivity penalties under pH 6.7 and 39 {degrees}C operation, targeted feed supplementation with galactose and MnCl2 consistently shifted glycoform profiles away from G0F toward galactosylated species (G1F, G1F', G2F). Crucially, coupling this combined feed strategy with an intensified perfusion rate (1.2 VVD) achieved a sustained, desired galactosylation shift without a productivity cost. These findings demonstrate that nutrient feed composition and perfusion rate are primary levers for steering continuous intensified microperfusion processes for biologics production with desired N-glycoform states and highlight the utility of automated at-line PAT like N-GLYcanyzer for enabling real-time attribute-based control in continuous biomanufacturing.

bioengineering↗

Differential sensing with imprinted and non-imprinted organic electrochemical transistors reduces calibration drift in wearable sweat cortisol sensors

The output of a wearable cortisol sensor drifts over days for reasons unrelated to cortisol, so a calibration made on the first day soon stops being valid. In our differential organic electrochemical transistor, a PEDOT:PSS transistor coated with a molecularly imprinted polymer (MIP) for cortisol is paired with one coated with a non-imprinted polymer (NIP) of the same composition, and the NIP response is subtracted. Over four calibrations in artificial sweat across 14 days, the response of the MIP alone shifted by 15% to 22% of its range on day 1, whereas the differential output shifted by 1% to 10%, and the variation between days at 1 to 10nM fell by 65% to 70% on average for individual pairs. In sweat from one participant, read against the calibration from day 1, both outputs tracked the direction of visible changes in salivary cortisol, while the MIP alone diverged from the differential output, consistent with the laboratory drift.

bioengineering↗