bioRxiv · 10.1101/627869
The reliability of the isotropic fractionator method for counting total cells and neurons
Abstract
BackgroundThe Isotropic Fractionator (IF) is a method used to determine the cellular composition of nervous tissue. It has been mostly applied to assess variation across species, where differences are expected to be large enough not to be masked by methodological error. However, understanding the sources of variation in the method is important if the goal is to detect smaller differences, for example, in same-species comparisons. Comparisons between different mice strains suggest that the IF is consistent enough to detected these differences. Nevertheless, the internal validity of the method has not yet been examined directly.\n\nMethodIn this study, we evaluate the reliability of the IF method for the determination of cellular and neuronal numbers. We performed repeated cell counts of the same material by different experimenters to quantify different sources of variation.\n\nResultsIn total cell counts, we observed that for the cerebral cortex most of the variance was at the counter level. For the cerebellum, most of the variance is attributed to the sample itself. As for neurons, random error along with the immunological staining correspond to most of the variation, both in the cerebral cortex and in the cerebellum. Test-retest reliability coefficients were relatively high, especially for cell counts.\n\nConclusionsAlthough biases between counters and random variation in staining could be problematic when aggregating data from different sources, we offer practical suggestions to improve the reliability of the method. While small, this study is a most needed step towards more precise measurement of the brains cellular composition.\n\nHighlightsO_LIMost variance in cell counts was between counters ({eta} = 0.58) for cerebral cortices.\nC_LIO_LIFor cerebella, most of the variance was attributed to the samples ({eta} = 0.49).\nC_LIO_LIVariance in immunocytochemical counts was mostly residual/random ({eta} > 0.8).\nC_LIO_LITest-retest reliability was high (same counter, same sample).\nC_LIO_LIPractical suggestions are offered to improve the reliability of the method.\nC_LI
Source connections
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Neves, K., Menezes Guimaraes, D. M., Rayee, D., Valerio-Gomes, B., Meneses Iack, P., Lent, R., Mota, B.. 2019-05-05. The reliability of the isotropic fractionator method for counting total cells and neurons. https://doi.org/10.1101/627869
Cite the original work for its findings. Save a collection to share your selection of sources.