bioRxiv ScienceSearch

bioRxiv · 10.1101/555136

Spatial Correlation and Breast Cancer Risk

Abstract

We present a novel method for evaluating the spatial correlation structure in two-dimensional (2D) mammograms and evaluate its merits for risk prediction. Two matched case-control studies were analyzed. Study 1 included women (N = 588 pairs) with mammograms acquired with either Hologic Selenia full field digital mammography (FFDM) units or Hologic Dimensions digital breast tomosynthesis units. Study 2 included women (N =180 pairs) with mammograms acquired with a General Electric Senographe 2000D FFDM unit. Matching variables included age, HRT usage/duration, screening history, and mammography unit. The local autocorrelation function was determined with Fourier analysis and compared with template defined as 2D double-sided exponential function with one spatial extent parameter: n = 4, 12, 24, 50, 74, 100, and 124 defined in pixel widths. The difference between local correlation and template was gauged within a kernel with an adjustable parameter and summarized, producing two measures: the mean (mn+1), and standard (sn+1). Both adjustable parameters were varied in Study 1. Select measures that produced significant associations with breast cancer were translated to Study 2. Breast cancer associations were evaluated with conditional logistic regression, adjusted for body mass index and ethnicity. Odds ratios (ORs) were estimated as per standard increment with 95% confidence intervals (CIs). Two measures were selected for breast cancer association analysis in Study 1: m75 and s25. Both measures revealed significant associations with breast cancer: OR = 1.45 (1.23, 1.66) for m75 and OR = 1.30 (1.14, 1.49) for s25. When translating to Study 2, these measures also revealed significant associations: OR = 1.49 (1.12, 1.96) for m75 and OR = 1.34 (1.06, 1.69) for s25. Novel correlation metrics presented in this work revealed significant associations with breast cancer risk. This approach is general and may have applications beyond mammography.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fowler, E. E., Hathaway, C., Tillman, F., Weinfurtner, R., Sellers, T. A., Heine, J.. 2019-02-21. Spatial Correlation and Breast Cancer Risk. https://doi.org/10.1101/555136

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering