bioRxiv Science⌕ Search

bioRxiv · 10.1101/407072

Frame Rate Up-Conversion in Echocardiography Images, Using Manifold-Learning and Image Registration

Abstract

In this paper, we propose a new temporal frame interpolation algorithm for frame rate up-conversion (FRUC) in echocardiography images. This algorithm employs a combination of dimension reduction techniques and image registration to increase frame rate.\n\nIf the distance between two successive frames of a video be great, motion jerkiness will appear between them and visual quality of the video will decrease. Some parts of heart have a very high speed motion, and echocardiography videos, obtained by available systems cant take enough number of frames to show them well. So, to achieve an echocardiography image set with a better visual quality, more frames are necessary between two frames at a great distance. Here, we use dimension reduction techniques to find out the number of suitable frames between two consecutive frames to show the fast motions better, but dont take much time. We project images to a 3-dimentional space by this way. Greater difference between the frames, results greater distance between corresponding embedded points. Thus, the distance between the embedded points is a scale for the suitable number of frames, needed between two successive frames. These frames are produced with the registration techniques.\n\nOn the other hand, heart doesnt have a constant speed during a cycle, but echocardiography images are recorded with constant speed. So, frames at a greater distance show fast motions of the heart, and frames at a lower distance show slow motions of the heart. While, we put unequal number of frames between successive frames, and in this way remove temporal coordination of the image set. To solve this problem, we put efficient number of linear average of available frames, in places that the number of inserted frames in between available frames is less than maximum to obtain an equal number of frames between all successive frames.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Daneshi, A., Behnam, H., Alizadeh Sani, Z.. 2018-09-03. Frame Rate Up-Conversion in Echocardiography Images, Using Manifold-Learning and Image Registration. https://doi.org/10.1101/407072

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

N-GLYcanyzer monitoring of a microperfusion process reveals critical parameters' impact on Trastuzumab biosimilar N-glycoform time evolution

Controlling monoclonal antibody (mAb) N-glycosylation as a critical quality attribute (CQA) remains challenging in continuous and intensified biomanufacturing, where conventional end-point analyses obscure dynamic pathway responses. Here, we deployed the N-GLYcanyzer process analytical technology (PAT) for automated monitoring of a microperfusion process that reveals critical parameters' impact on Trastuzumab biosimilar N-glycoform time evolution across a 20-day culture duration of Chinese Hamster Ovary (CHO) cells in a ~2 mL scale-down microbioreactor perfusion platform. Using offline PAT assays combined with our integrated at-line PAT workflow, we systematically screened six perfusion process parameters: carbon source, viable cell density (VCD), perfusion rate, temperature, and pH. While nutrient limitation and thermal/acidic stress significantly disrupted N-glycans maturation, notably triggering high-mannose (Man5) accumulation and severe productivity penalties under pH 6.7 and 39 {degrees}C operation, targeted feed supplementation with galactose and MnCl2 consistently shifted glycoform profiles away from G0F toward galactosylated species (G1F, G1F', G2F). Crucially, coupling this combined feed strategy with an intensified perfusion rate (1.2 VVD) achieved a sustained, desired galactosylation shift without a productivity cost. These findings demonstrate that nutrient feed composition and perfusion rate are primary levers for steering continuous intensified microperfusion processes for biologics production with desired N-glycoform states and highlight the utility of automated at-line PAT like N-GLYcanyzer for enabling real-time attribute-based control in continuous biomanufacturing.

bioengineering↗

Differential sensing with imprinted and non-imprinted organic electrochemical transistors reduces calibration drift in wearable sweat cortisol sensors

The output of a wearable cortisol sensor drifts over days for reasons unrelated to cortisol, so a calibration made on the first day soon stops being valid. In our differential organic electrochemical transistor, a PEDOT:PSS transistor coated with a molecularly imprinted polymer (MIP) for cortisol is paired with one coated with a non-imprinted polymer (NIP) of the same composition, and the NIP response is subtracted. Over four calibrations in artificial sweat across 14 days, the response of the MIP alone shifted by 15% to 22% of its range on day 1, whereas the differential output shifted by 1% to 10%, and the variation between days at 1 to 10nM fell by 65% to 70% on average for individual pairs. In sweat from one participant, read against the calibration from day 1, both outputs tracked the direction of visible changes in salivary cortisol, while the MIP alone diverged from the differential output, consistent with the laboratory drift.

bioengineering↗

A cytotoxicity dataset for data-driven design of ionizable lipid nanoparticles

Ionizable lipid nanoparticles (LNPs) are widely used to deliver nucleic acid therapeutics, but the design of safe LNPs remains challenging due to the complex activity relationships among structure, composition, and physicochemical properties. Here, we present a curated dataset, the Lipid Nanoparticle Cytotoxicity Database (LNPCD), which aggregates 1,413 LNP cytotoxicity measurements across 1,288 unique ionizable lipids drawn from 11 high-throughput combinatorial studies. Lipid structures were generated computationally from the published libraries and manually verified against the original publications. Each record pairs a machine-readable SMILES representation of the ionizable lipid with its measured viability endpoint and the associated experimental descriptors, including cell line, dose, and cargo type. The dataset provides a traceable resource for examining how ionizable lipid structure and experimental conditions relate to in vitro cell viability, and for developing and evaluating computational models of lipid nanoparticle cytotoxicity.

bioengineering↗