bioRxiv Science⌕ Search

bioRxiv · 10.1101/317602

The Effects of Different Vibration Frequencies, Amplitudes and Contraction Levels on Lower Limb Muscles during Graded Isometric Contractions Superimposed on Whole Body Vibration Stimulation

Abstract

BackgroundIndirect vibration stimulation i.e. whole body vibration or upper limb vibration, has been suggested increasingly as an effective exercise intervention for sports and rehabilitation applications. However, there is a lack of evidence regarding the effects of whole body vibration (WBV) stimulation superimposed to graded isometric contractions superimposed on. For this scope, we investigated the effects of WBV superimposed to graded isometric contractions in the lower limbs on muscle activation. We also assessed the agonist-antagonist co-activation during this type of exercise.\n\nTwelve healthy volunteers were exposed to WBV superimposed to graded isometric contractions, at 20, 40, 60, 80 and 100% of the maximum voluntary contractions (V) or just isometric contractions performed on a custom designed horizontal leg press Control (C). Tested stimulation consisted of 30Hzand 50Hz frequencies and 0.5mm and 1.5mm amplitudes. Surface electromyographic activity of Vastus Lateralis (VL), Vastus Medialis (VM) and Biceps Femoris (BF) were measured during V and C conditions. Co-contraction activity of agonist-antagonist muscles was also quantified. The trials were performed in random order.\n\nResultsBoth the prime mover, (VL) and the antagonist, (BF) displayed significantly higher (P < 0.05) EMG activity with the V than the C condition. For both the VL and BF, the increase in mean EMGrms values depended on the frequency, amplitude and muscle contraction level with 50Hz-0.5mm stimulation inducing the largest neuromuscular activity. 50Hz-0.5mm V condition also led to co-activation ratios significantly (P< 0.05) higher at 40, 80 and 100% of MVC than the C condition.\n\nConclusionsOur results show that the isometric contraction superimposed on vibration stimulation leads to higher neuromuscular activity compared to isometric contraction alone in the lower limbs. Compared to the control condition, the vibratory stimulation leads to higher agonist-antagonist co-activation of the muscles around the knee joint in all vibration conditions and effort levels. The combination of vibration magnitude (frequency and amplitude) and the level of muscle contraction affect neuromuscular activity rather than vibration frequency alone. Results of this study suggest that more parameters need to be taken into consideration when designing vibration exercise programs for sports and rehabilitation purposes.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Pujari, A. N., Neilson, R. D., Cardinale, M.. 2018-05-08. The Effects of Different Vibration Frequencies, Amplitudes and Contraction Levels on Lower Limb Muscles during Graded Isometric Contractions Superimposed on Whole Body Vibration Stimulation. https://doi.org/10.1101/317602

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Engineered microvessel networks -- Longitudinal transcriptomic profiling validates chip-grown tissues as a robust model for studying vasculature

Vascularised Organ-on-Chip (OoC) models are promising New Approach Methodologies (NAMs), but their translation requires validation for defined Contexts of Use (CoU). Here, we combine microfluidic microvessel networks (MVNs) with longitudinal bulk and single-cell RNA sequencing to determine how cell provenance influences engineered vascular phenotype. Stromal cell identity produced distinct network architectures and transcriptional trajectories, demonstrating that support cells, commonly treated as interchangeable, represent an important CoU variable. Primary human pancreatic microvascular endothelial cells failed to form stable perfusable networks, but supplementation with 10% Human Umbilical Vein Endothelial Cells (HUVECs) or Blood Outgrowth Endothelial Cells (BOECs) rescued self-assembly. Single-cell transcriptomics identified specialised endothelial populations associated with vascular morphogenesis, including tip, stalk, phalanx, endothelial to mesenchymal transition (EndMT) and pericyte-like endothelial cells. Failed networks lacked coherent endothelial specialisation, whereas rescued networks restored stabilising cell states and revealed FLRT2--UNC5B signalling within pericyte-like HUVECs, recapitulating a pathway implicated in angiogenic development in vivo. These findings establish cell provenance as a critical determinant of microvascular NAM performance and demonstrate how transcriptomic validation can define and strengthen the biological relevance of microvessel-on-chip models for specific CoUs.

bioengineering↗

Benchmarking foundation models for resting-state functional magnetic resonance imaging time series in cognitive aging research

Foundation models trained on large neuroimaging datasets could help smaller studies investigate cognition from brain recordings. However, whether the foundation model-derived representations improve assessment of current cognition, prediction of follow-up cognition, or characterization of cognitive change remains unclear. We evaluated nine configurations from five model families that process regional resting-state functional magnetic resonance imaging time series, using 3,103 scans from 1,653 participants across two observational and five intervention aging cohorts. Primary frozen representations showed no consistent superiority over conventional functional connectivity for concurrent cognitive associations or diagnostic classification. Changing the readout improved selected concurrent cognitive associations without updating model weights, indicating that performance depended partly on how representations were extracted. Additional post-training and embedding alignment yielded gains in selected settings but did not consistently improve performance across outcomes. In the primary longitudinal analyses, imaging representations did not establish added value beyond baseline clinical measures. These findings show that readout choice influences concurrent cognitive associations, while the added value of these representations for longitudinal outcomes remains unestablished.

bioengineering↗

PROST: An Open Toolbox, Harmonised Multi-Lab Dataset, and Meta-Analysis of Ankle-Foot Roll-Over Shape

The ankle-foot roll-over shape (ROS) is the sagittal-plane path of the centre of pressure (CoP) during the stance phase of walking, expressed in a shank-based coordinate system. It describes the effective rocker geometry that emerges from both the shape and the elastic deformation of the ankle-foot system during walking, and informs prosthetic and orthotic design. Previous studies characterised ROS in small samples with differing laboratory protocols, so they have not systematically assessed inter-individual variability or its relation to anthropometrics. We developed the open-source Public ROS Toolbox (PROST) for standardised ROS computation, and used it to harmonise marker trajectories, ground reaction forces and CoP data from four public gait datasets collected in independent laboratories. For each leg, we fitted a circular arc to the pooled ROS of all its stance phases. In a one-stage individual-participant data meta-analysis, linear mixed-effects models, with dataset as a fixed effect and participant as a random intercept, related the arc radius and the horizontal coordinate of the circle centre to anthropometrics, and, in the two self-selected-speed datasets, to walking speed. The harmonised dataset comprises 249 participants and 5,667 stance phases at walking speeds of 0.7-8.5 km/h. Circular arcs fitted the ROS closely (mean RMS radial residual 1.9 mm). The radius had a median of 410.3 mm (interquartile range, IQR, 237.6 mm), and the circle centre lay posterior to the ankle (median -20.6 mm, IQR 49.5 mm). Between-participant differences, quantified by the intraclass correlation coefficient (ICC), accounted for 42% of the variance in log radius (95% CI 25-57%) and 47% of the variance in the horizontal coordinate of the circle centre (95% CI 24-65%). Anthropometrics explained a negligible share of this variance (radius: pseudo-R2 -0.001, 95% CI -0.03 to 0.12), and height normalisation did not reduce radius variability (robust coefficient of variation 43% with and without normalisation). Faster self-selected walking was associated with a larger radius and a more posterior circle centre. To our knowledge, this study provides the first harmonised multi-lab ROS dataset. Together with the open-source toolbox, it is publicly available to support reproducible research in gait biomechanics, rehabilitation device design and clinical gait assessment. ROS geometry was participant-specific but was not predicted by age, sex, height or mass. A device ROS scaled from anthropometrics is therefore unlikely to match an individual's ROS, motivating studies of whether matching it, through device geometry and stiffness, improves gait mechanics.

bioengineering↗