Standardized microgel beads as elastic cell mechanical probes

Abstract

Cell mechanical measurements are gaining increasing interest in biological and biomedical studies. However, there are no standardized calibration particles available that permit the cross-comparison of different measurement techniques operating at different stresses and time-scales. Here we present the rational design, production, and comprehensive characterization of poly-acylamide (PAAm) microgel beads mimicking biological cells. We produced mono-disperse beads at rates of 20 - 60 kHz by means of a microfluidic droplet generator, where the pre-gel composition was adjusted to tune the beads elasticity in the range of cell and tissue relevant mechanical properties. We verified bead homogeneity by optical diffraction tomography and Brillouin microscopy. Consistent elastic behavior of microgel beads at different shear rates was confirmed by AFM-enabled nanoindentation and real-time deformability cytometry (RT-DC). The remaining inherent variability in elastic modulus was rationalized using polymer theory and effectively reduced by sorting based on forward-scattering using conventional flow cytometry. Our results show that PAAm microgel beads can be standardized as mechanical probes, to serve not only for validation and calibration of cell mechanical measurements, but also as cell-scale stress sensors.\n\nSignificance StatementOften vastly different cell mechanical properties are reported even for the same cell type when employing different measurement techniques. This discrepancy shows the urgent need for standardized calibration particles to cross-compare and validate techniques. Microgel beads can serve this purpose, but they have to fulfil specific requirements such as homogeneity, sizes and elasticities in the range of the cells, and they have to provide comparable results independent of the method applied. Here we demonstrate the standardized production of polyacrylamide microgel beads with all the features an elastic cell-mimic should have. These can not only be used as method calibration particles, but can also serve as cell-scale sensors to quantify normal and shear stresses exerted by other cells and inside tissues, enabling many new applications.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Girardo, S., Traeber, N., Wagner, K., Cojoc, G., Herold, C., Goswami, R., Schluessler, R., Abuhattum, S., Taubenberger, A., Reichel, F., Mokbel, D., Herbig, M., Schuermann, M., Mueller, P., Heida, T., Jacobi, A., Thiele, J., Werner, C., Guck, J.. 2018-03-28. Standardized microgel beads as elastic cell mechanical probes. https://doi.org/10.1101/290569

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Kinetic gating by an iron sulfur chain modulates flavin radical-pair spin chemistry in mitochondrial Complex I

Mitochondrial Complex I generates reactive oxygen species at its flavin cofactor, where spin dependent reaction pathways have been proposed. Models of this chemistry treat the flavin oxygen radical pair in isolation, although the flavin is wired to a chain of eight iron sulfur clusters. Here we model the pair with this chain using the human Complex I structure and open quantum system models of spin coupling and electron transfer. In the simulated network, spin coherence decays rapidly along the chain, whereas proximal clusters alter the calculated radical-pair singlet yield. Their influence is kinetically gated: a downstream cluster affects the modelled yield when its electron-transfer rate competes with radical pair recombination, a threshold robust to driving force and to the transfer model. Modelling does set the sign: one directional spin hops predict suppression and inflate coherence transport, whereas charge resolved transfer drives the singlet yield towards its spin-randomized limit unless triplet recombination dominates. Detectable spin dependent effects in this framework require superoxide spin relaxation to be substantially slower than in free solution, a condition not yet established for Complex I.

biophysics↗

Semidilute Polymer Scaling Controls PEG-induced Protein Phase Separation

When does polyethylene glycol (PEG) mass concentration provide a common measure of crowding strength across polymer chain lengths? Here we use bovine serum albumin (BSA) and PEG as a controlled depletion system and measure both coexisting phases to determine binodals, tie lines, and critical points across PEG molecular weights of 4--100 kDa. Phase diagrams for PEG 20, 35, and 100 kDa approximately collapse in mass-concentration coordinates, consistent with semidilute polymer scaling. Generalized free volume theory (GFVT) describes the BSA binodals and tie lines. It also approximately describes binodals for three additional globular proteins in PEG 35K, extending the comparison across proteins spanning 7.2--66.4 kDa. For the binary PEG mixtures tested, GFVT approximates the binodals using an effective polymer size corresponding to the weight-average molecular weight. These results identify a regime in which PEG mass concentration (g/L) provides a transferable measure of depletion-induced crowding.

biophysics↗

Correlation-resolved sum-frequency generation microscopy of biological tissue with bright twin beams

Sum-frequency generation (SFG) driven by bright twin beams generated through high-gain parametric down-conversion comprises a coherent component arising from correlated mode pairs and an incoherent component arising from interactions between uncorrelated modes. Modal correlations can enhance coherent SFG in anisotropic nonlinear media, for example by extending the effective interaction length. Whether such correlations can likewise benefit image formation in heterogeneous biological tissue remains unknown. Here we address this question by performing SFG imaging of biological tissue using bright twin beams as the excitation source. Spectral decomposition of the SFG signal separates its coherent and incoherent components, allowing us to reconstruct co-registered images and examine how twin-beam correlations influence image formation. In mouse skeletal muscle, the coherent-component image revealed sarcomere periodicity with a Bragg-spot-to-background ratio of approximately 310, compared with 7.5 in the incoherent-component image. In fresh human dermis, the coherent-component image showed greater Fourier power than the incoherent-component image in the 0.30-0.50 \mu m^{-1} band and a greater fractional autocovariance decay at short spatial lags. These results demonstrate that twin-beam correlations can enhance contrast and detectability at selected spatial frequencies in heterogeneous tissue. Correlation-resolved SFG microscopy thus offers a route for exploiting bright quantum-light sources in nonlinear optical bioimaging.

biophysics↗