bioRxiv · 10.1101/260737
PSF correction in soft x-ray tomography
Abstract
In this manuscript, we introduce a linear approximation of the forward model of soft x-ray tomography (SXT), such that the reconstruction is solvable by standard iterative schemes. This linear model takes into account the three-dimensional point spread function (PSF) of the optical system, which consequently enhances the reconstruction data. The feasibility of the model is demonstrated on both simulated and experimental data, based on theoretically estimated and experimentally measured PSFs.
Source connections
Explore related subjects
Keep this discovery
Ekman, A., Weinhardt, V., Chen, J.-H., McDermott, G., Le Gros, M., Larabell, C.. 2018-02-05. PSF correction in soft x-ray tomography. https://doi.org/10.1101/260737