bioRxiv Science⌕ Search

bioRxiv · 10.1101/254557

EEG-based personal identification: comparison of different functional connectivity metrics

Abstract

Growing interest is devoted to understanding how brain signals recorded from scalp electroencephalography (EEG) may represent unique fingerprints of individual neural activity. In this context, the present paper aims to investigate the impact of some of the most commonly used techniques to estimate functional connectivity on the ability to unveil personal distinctive patterns of inter-regional interactions. Different metrics, commonly used to estimate functional connectivity and derived centrality measures, were compared in terms of equal error rate. It is widely accepted that each metric carries specific information in respect to the underlying interactions network. Nevertheless, the reason why these metrics convey different subject specific information has not been investigated yet. Experimental results on two publicly available datasets suggest that different functional connectivity metrics define a peculiar subjective profile of connectivity and have different mechanisms to detect subject-specific patterns of inter-channel interactions. It is important to consider the effects that frequency content and spurious connectivity values may play in determining subject-specific characteristics.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Fraschini, M., Marcialis, G. L., Didaci, L.. 2018-01-30. EEG-based personal identification: comparison of different functional connectivity metrics. https://doi.org/10.1101/254557

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Engineering and characterisation of AAVS1 FRT cell lines for inducible and dose-dependent gene expression

Investigating biological function with high reproducibility requires the generation of stable cell lines that offer precise and inducible transgene expression. However, traditional methods often suffer from the limitations of random genomic integration, including unpredictable expression levels, leaky basal activity, and disruption of endogenous loci. To address these challenges, we engineered a versatile RPE1 cell line by integrating a TetOn3G-FRT cassette into the AAVS1 safe-harbour locus using CRISPR/Cas9(D10A) nickase. This platform utilises the Flp-FRT recombination system to facilitate rapid, site-specific "plug-and-play" insertion of transgenes, combined with the Tet-On 3G system for tight, dose-dependent expression control. The resulting RPE1 AAVS1 FRT8 line enables highly consistent transgene induction across independent clones, behaving as a monoclonal population. We highlight the importance of rigorous cell line characterisation through a multi-omics approach. Whole genome sequencing identified precise heterozygous integration at the target locus and de novo genomic duplications on other chromosomes. By integrating WGS with high-resolution proteomics and cell cycle analysis, we confirmed that these alterations did not significantly perturb cellular homeostasis or phenotypic fitness. This work establishes a robust and reliable platform for the efficient generation of inducible AAVS1 FRT stable cell lines, facilitating reproducible research in modern molecular biology.

bioengineering↗

Raman-probe-derived biomarkers account for cartilage composition, structure, and viscoelastic properties

Raman spectroscopy is an inelastic light scattering technique that reflects the vibrational modes of the biochemical building blocks of the major constituents that comprise the cartilage extracellular matrix (ECM): glycosaminoglycans (GAG), type-II collagen (COL), and water. We investigated whether ECM-specific biomarkers measured with our recently developed arthroscopy-compatible Raman needle probe characterize the functional viscoelastic properties of articular cartilage explants. Equine osteochondral explants were harvested from high-load (femoral condyle) and low-load (intertrochlear groove) sites to evaluate Raman-derived biomarkers of cartilage structure and function. Viscoelastic material properties (equilibrium/dynamic modulus, phase shift) were determined by mechanical indentation. A computational fibril-reinforced biphasic material model was used to estimate the glycosaminoglycan-associated non-fibrillar-matrix modulus, the collagen-associated fibril-network modulus, and hydraulic permeability. Raman-derived biomarkers enabled evaluation of cartilage tissue composition and structure, accounting for 81% of the variation in GAG content, 53% of the variation in COL content, and 58% of the variation in COL anisotropy. Biomarkers also accounted for 81% of the variation in equilibrium modulus, 58% in dynamic modulus, and 51% in phase shift. For poroelastic properties, biomarkers accounted for 83% of the variation in non-fibrillar-matrix modulus, 25% of the variation in fibril-network modulus, and 34% of the variation in hydraulic permeability. Clinical Significance: Raman spectroscopy provides objective compositional biomarkers that account for viscoelastic material properties underlying articular cartilage function. These findings support its future use as an arthroscopic platform for objective assessment of cartilage injury, monitoring of disease progression, and evaluation of therapeutic interventions.

bioengineering↗

An adjuvant for in vivo CAR-T therapy potentiation against solid tumors

In vivo CAR-T therapy offers rapid and controllable T-cell engineering but has yet to achieve durable efficacy against solid tumors. Rather than focusing solely on CAR-T cells, we harness the intact immune system via an in vivo CAR-T adjuvant (iCTA). Composed of aluminum-manganese hydrogel, iCTA can form a spatially confined antigenic and immunostimulatory niche in-situ. By coupling controlled antigen exposure with STING-type I interferon signaling, iCTA not only recruited and reactivated CAR-T cells, but engage the CAR-negative immunocytes with enhanced dendritic-cell antigen presentation and mobilized endogenous antigen-specific T-cell responses. Combined with mRNA-LNP-mediated in vivo CAR-T generation, a single administration of iCTA increased CAR+ T-cell abundance in draining lymph nodes and blood by 2-fold. It also increased T and NK cell infiltration, established an IFNgamma-enriched tumor microenvironment, and reduced exhaustion-associated T-cell states. iCTA improved tumor regression and survival, establishing an adjuvant strategy to enhance in vivo CAR-T therapy.

bioengineering↗