bioRxiv ScienceSearch

bioRxiv · 10.1101/245258

Muscle stem cell intramuscular delivery within hyaluronan methylcellulose improves engraftment efficiency and dispersion

Abstract

Adult skeletal muscle tissue harbors the capacity for self-repair due to the presence of tissue resident muscle stem cells (MuSCs). Advances in the area of prospective MuSC isolation demonstrated the potential of cell transplantation therapy as a regenerative medicine strategy to restore strength and long-term regenerative capacity to aged, injured, or diseased skeletal muscle tissue. However, cell loss during ejection, limits to post-injection proliferation, and poor donor cell dispersion distal to the injection site are amongst hurdles to overcome to maximize MuSC transplant impact. Here, we assess a physical blend of hyaluronan and methylcellulose (HAMC) as a bioactive, shear thinning hydrogel cell delivery system to improve MuSC transplantation efficiency. Using in vivo transplantation studies, we found that the HAMC delivery system results in a >45% increase in the number of donor-derived fibers as compared to saline delivery. Furthermore, we observed a significant improvement in donor fiber dispersion when transplanted MuSCs were delivered in the HAMC hydrogel. Studies to assess primary myoblast and MuSC viability in HAMC culture revealed no differences compared to the media control even when the cells were first ejected through a syringe and needle or exposed to regenerating skeletal muscle extract to mimic the transplantation procedure. However, when we quantified absolute numbers, we found that more cells pass through the syringe and needle when delivered in HAMC. Culture in HAMC also increased the proportion of MuSCs in cell cycle, via a CD44-independent mechanism. An effect on myoblast proliferation was not observed, suggesting a hierarchical effect. Finally, a series of transplant studies indicated that HAMC delivery does not influence passive cell clearance or alter the host immune response, but instead may serve to support in vivo expansion by delaying differentiation following transplant. Therefore, we conclude that MuSC engraftment efficacy is improved by delivering the therapeutic cell population within HAMC.

Source connections

Explore related subjects

Keep this discovery

BibTeXRIS

Davoudi, S., Chin, C.-Y., Cooke, M. C., Tam, R. Y., Shoichet, M. S., Gilbert, P. M.. 2018-01-09. Muscle stem cell intramuscular delivery within hyaluronan methylcellulose improves engraftment efficiency and dispersion. https://doi.org/10.1101/245258

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Comparative study of chlorophyll measurement in Physcomitrium patens moss using a conventional microscope adapted for combined 2D+1D imaging and spectral analysis

Imaging spectroscopy often requires expensive and complex equipment. Here we show a simple procedure for attaching a standard miniature fiber spectrometer to a conventional microscope, allowing easy integration of 2D imaging with 1D high-resolution spectral measurements. This combination provides much of the benefit of a full imaging spectrometer without the large equipment investment, and we provide instructions for modifying microscopes to this setup and the present measurements of living cells that demonstrate their performance. Using this setup, we compare the quantitative measurement of chlorophyll concentration in Physcomitrium patens moss using color imaging and spectral sampling.

bioengineering

De novo designed single-domain antibodies protect against lethal cobra venom neurotoxicity in vivo

Generative protein design can now rapidly produce de novo binders with high affinity and functional activity against a wide range of targets, including lethal snake venom toxins. However, so far most reported successes rely on new-to-nature scaffolds with limited therapeutic precedent. Single-domain antibodies (VHHs) offer a clinically validated alternative scaffold that can bind and neutralize long-chain -neurotoxins, which are some of the most lethal components in snake venoms. Here we compare three recently established de novo design models with VHH-design capabilities (Germinal, RFantibody, and BoltzGen) for their ability to generate VHHs against the neurotoxin -cobratoxin from the monocled cobra (Naja kaouthia). Using standardized model inputs and evaluation criteria based on AlphaFold3 interface confidence (ipTM) and RMSD self-consistency, we find that Germinal was the only method to generate designs passing stringent in silico criteria for experimental testing. We therefore performed a larger Germinal design campaign employing three different VHH frameworks and experimentally validated 46 designs in vitro. Of these, 42 expressed as soluble proteins and we identified four binding hits derived from two of the three tested frameworks. Of the four binders, two lead candidates were further characterized and demonstrated high affinity (KDs of 4.1 nM and 10.8 nM), monomeric behavior and low polyreactivity, indicating favorable biophysical and developability properties, as well as functional toxin neutralization in vitro. To assess their therapeutic potential we investigated their ability to protect against -cobratoxin toxicity in vivo. Both candidates fully protected mice after -cobratoxin challenge, with 100% survival compared to a lethal control. One candidate also retained notable neutralization capacity against whole venom of Naja kaouthia with a survival of 56%, while the other protected 22% when tested in a rescue setting. Together, we demonstrate that de novo VHH design can generate high affinity single-domain antibodies with in vivo protection against lethal cobra venom neurotoxicity, and provide practical insights into method- and framework-dependent performance.

bioengineering

Simple Feedback for Complex Movement: Capturing Whole-Limb Reorganization during Single-IMU Gait Retraining

Clinical gait retraining typically relies on multi-sensor arrays and high-dimensional feedback displays, imposing setup and interpretation burdens that limit routine clinical deployment. We developed a single-IMU visual biofeedback system that delivers real-time feedback of Lower Limb Trajectory Error (LLTE), a composite kinematic error metric integrating knee position and shank angle across the stance phase. Twenty able-bodied adults walked on a treadmill under two visual biofeedback targets (flexed-knee, extended-knee) while receiving either corrected (n=10) or uncorrected (n=8) feedback, where the correction accounted for limb orientation at initial contact. LLTE and stance-phase knee kinematics adapted consistently under the flexed-knee target for both feedback groups, with feedback formulation moderating the temporal trajectory of change. Adaptation toward the extended-knee target was limited, likely because participants were already operating near terminal knee extension and because the scalar error metric provided limited directional information for correction. Ankle range of motion (ROM) changed significantly across the stance phase under both target conditions, while hip ROM did not. Multiscale multivariate sample entropy (MSMVSE) increased monotonically with time scale across all conditions, with no statistically distinguishable difference between corrected and uncorrected feedback. These results suggest that single-IMU LLTE biofeedback can modify gait mechanics and that adaptation was expressed across multiple lower-limb segments rather than through changes at a single joint.

bioengineering