bioRxiv Science⌕ Search

bioRxiv · 10.1101/204099

Automated Reactive Accelerated Aging for Rapid In Vitro Evaluation of Neural Implants Performance

Abstract

ObjectiveNovel therapeutic applications for neural implants require miniaturized devices. Pilot clinical studies suggest that rapid failure of the miniaturized neural implants in the body presents a major challenge for this type of technology. Miniaturization imposes stricter requirements for reliability of materials and designs. Evaluation of neural implant performance over clinically relevant timescales presents time-and cost-prohibitive challenges for animal models.\n\nApproachIn vitro reactive accelerated aging (RAA) was developed to expedite durability testing of these devices. RAA simulates an aggressive physiological environment associated with an immune response and implicated in device failure. It uses hydrogen peroxide, which mimics reactive oxygen species (ROS), and high temperature to accelerate chemical reactions that lead to device degradation. RAA accurately simulates the degradation pattern of neural implants observed in vivo, but requires daily maintenance and is prone to variability in performance.\n\nMain resultsThis work introduces automated reactive accelerated aging (aRAA) that is compatible with multiplexing. The core of aRAA is electrochemical detection for feedback control of hydrogen peroxide concentration, implemented with simple off-the shelf components.\n\nSignificanceaRAA allows multiple parallel experiments for a high-throughput optimization of reactive aging conditions to more quickly and more rigorously simulate the in vivo environment. aRAA is a cost-effective tool for rapid in vitro evaluation of durability of neural implants, ultimately expediting the development of a new generation of miniaturized devices with long functional lifespans.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Street, M. G., Welle, C. G., Takmakov, P. A.. 2017-10-17. Automated Reactive Accelerated Aging for Rapid In Vitro Evaluation of Neural Implants Performance. https://doi.org/10.1101/204099

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

N-GLYcanyzer monitoring of a microperfusion process reveals critical parameters' impact on Trastuzumab biosimilar N-glycoform time evolution

Controlling monoclonal antibody (mAb) N-glycosylation as a critical quality attribute (CQA) remains challenging in continuous and intensified biomanufacturing, where conventional end-point analyses obscure dynamic pathway responses. Here, we deployed the N-GLYcanyzer process analytical technology (PAT) for automated monitoring of a microperfusion process that reveals critical parameters' impact on Trastuzumab biosimilar N-glycoform time evolution across a 20-day culture duration of Chinese Hamster Ovary (CHO) cells in a ~2 mL scale-down microbioreactor perfusion platform. Using offline PAT assays combined with our integrated at-line PAT workflow, we systematically screened six perfusion process parameters: carbon source, viable cell density (VCD), perfusion rate, temperature, and pH. While nutrient limitation and thermal/acidic stress significantly disrupted N-glycans maturation, notably triggering high-mannose (Man5) accumulation and severe productivity penalties under pH 6.7 and 39 {degrees}C operation, targeted feed supplementation with galactose and MnCl2 consistently shifted glycoform profiles away from G0F toward galactosylated species (G1F, G1F', G2F). Crucially, coupling this combined feed strategy with an intensified perfusion rate (1.2 VVD) achieved a sustained, desired galactosylation shift without a productivity cost. These findings demonstrate that nutrient feed composition and perfusion rate are primary levers for steering continuous intensified microperfusion processes for biologics production with desired N-glycoform states and highlight the utility of automated at-line PAT like N-GLYcanyzer for enabling real-time attribute-based control in continuous biomanufacturing.

bioengineering↗

Differential sensing with imprinted and non-imprinted organic electrochemical transistors reduces calibration drift in wearable sweat cortisol sensors

The output of a wearable cortisol sensor drifts over days for reasons unrelated to cortisol, so a calibration made on the first day soon stops being valid. In our differential organic electrochemical transistor, a PEDOT:PSS transistor coated with a molecularly imprinted polymer (MIP) for cortisol is paired with one coated with a non-imprinted polymer (NIP) of the same composition, and the NIP response is subtracted. Over four calibrations in artificial sweat across 14 days, the response of the MIP alone shifted by 15% to 22% of its range on day 1, whereas the differential output shifted by 1% to 10%, and the variation between days at 1 to 10nM fell by 65% to 70% on average for individual pairs. In sweat from one participant, read against the calibration from day 1, both outputs tracked the direction of visible changes in salivary cortisol, while the MIP alone diverged from the differential output, consistent with the laboratory drift.

bioengineering↗

A cytotoxicity dataset for data-driven design of ionizable lipid nanoparticles

Ionizable lipid nanoparticles (LNPs) are widely used to deliver nucleic acid therapeutics, but the design of safe LNPs remains challenging due to the complex activity relationships among structure, composition, and physicochemical properties. Here, we present a curated dataset, the Lipid Nanoparticle Cytotoxicity Database (LNPCD), which aggregates 1,413 LNP cytotoxicity measurements across 1,288 unique ionizable lipids drawn from 11 high-throughput combinatorial studies. Lipid structures were generated computationally from the published libraries and manually verified against the original publications. Each record pairs a machine-readable SMILES representation of the ionizable lipid with its measured viability endpoint and the associated experimental descriptors, including cell line, dose, and cargo type. The dataset provides a traceable resource for examining how ionizable lipid structure and experimental conditions relate to in vitro cell viability, and for developing and evaluating computational models of lipid nanoparticle cytotoxicity.

bioengineering↗