bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.11.06.682452

3D Hybrid Bioprinting for Complex Multi-Tissue Engineering

Abstract

3D bioprinting has revolutionized tissue engineering, enabling intricate, physiologically relevant constructs unattainable with conventional techniques, yet it remains limited in integrating soft and rigid multifunctional components for complex multi-tissue applications. In this study, we introduce a 3D hybrid bioprinting approach implementing the Hybprinter platform, which integrates multiple 3D printing modules under optimized conditions for a continuous bioprinting process with multiple soft and hard biomaterials. This approach demonstrates robust biocompatibility and broad tissue engineering potential for modeling and therapeutic applications. The capacity to fabricate multi-hydrogel hybrid constructs is illustrated by representative examples highlighting vascularization, multifunctionality, mechanical robustness, and implant suturability. Notably, compared with commonly fabricated hydrogel-only constructs, the resulting hybrid constructs achieve over a 1000-fold increase in mechanical strength, and demonstrated enhanced osteogenic differentiation, underscoring their suitability for load-bearing musculoskeletal and orthopedic tissue engineering. Additionally, cell-laden hydrogel constructs demonstrated robust chondrogenic differentiation, highlighting the capacity for lineage-specific tissue development in vitro. Beyond these outcomes, the presented hybrid bioprinting approach integrates essential tissue engineering attributes that unites mechanical robustness and suturable capacity with multi-material integration, gradient property design, incorporation of bioactive agents, and support for multi-cell loading. This versatile platform advances complex tissue engineering and holds promise for patient specific, organ-on-demand applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Alizadeh, H. V., Flores Perez, A. S., Uno, T., Muniz, R. S., Kwon, S. H., Balachandar, A., Riley, N., Le, C. A., Li, J., Zhao, P., Lui, E., Kim, C., Moeinzadeh, S., Pan, C.-C., Bhutani, N., Chu, C., Kim, S., Yang, Y. P.. 2025-11-07. 3D Hybrid Bioprinting for Complex Multi-Tissue Engineering. https://doi.org/10.1101/2025.11.06.682452

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Dynamic Compression Platform for Live Imaging of Scaffold-Transmitted Cellular Mechanoresponses

Mechanical characterization of biomaterial scaffolds is essential to evaluate their capacity to meet the functional demands of target tissues in tissue engineering and regenerative medicine applications. Scaffolds designed to interface with living tissues must support the transmission of mechanical cues to resident cells and stimulate mechanosignaling pathways that are essential to their function. In joints, bone and cartilage cells act as primary mechanosensors, converting mechanical stimuli into biochemical signals that regulate tissue homeostasis and remodelling. Therefore, evaluating cellular mechanoresponses to scaffold-transmitted compression in vitro can inform the development of functional tissue-engineered constructs. For example, poly({epsilon}-caprolactone) (PCL) scaffolds are highly relevant for bone and cartilage tissue engineering due to their biocompatibility, stable mechanical properties and slow degradation. Here, we applied a custom-built device to study compression-induced mechanosignaling in MC3T3-E1 pre-osteoblast cells. The device is composed of a polydimethylsiloxane (PDMS) pillar, a force-sensing load cell, and a piezoelectric linear track. A protocol is described in which MC3T3-E1 cells are repeatedly compressed, while in parallel live tracking of force measurements and live imaging of intracellular calcium dynamics in MC3T3-E1 cells are recorded. PCL scaffolds fabricated by melt electrowriting (MEW) were subsequently integrated into the platform. Scaffold-transmitted compression triggered dynamic increases in cytosolic calcium; in MC3T3-E1 cells located directly under the PCL microfibers, but also in cells located in the interfiber spaces. This device and workflow facilitate in vitro investigations of real-time cellular mechanoresponses to dynamic compression applied with biomaterial scaffolds, and provides a testing platform for evaluating the mechanotransductive properties of scaffolds intended for tissue engineering applications.

bioengineering↗

Ultrasound Tracking Reveals Progressive Regional Strain Differences in Human Achilles Tendons During Fatigue Loading

Ultrasound is commonly used to assess structural changes in symptomatic Achilles tendons, but quantitative biomechanical metrics for progressive tendon deterioration remain limited. The goal of this study was to develop and validate an automated ultrasound tracking algorithm for regional tendon deformation and evaluate strain progression in survived and ruptured tendons during fatigue loading. We hypothesized that maximum strain, average strain, and strain heterogeneity would exhibit different trajectories between groups. Ten cadaveric Achilles tendons underwent cyclic loading with stress tests every 500 cycles until rupture or 150,000 cycles. Ultrasound images acquired during stress tests were analyzed using an automated tracking algorithm to generate spatially resolved regional strain fields. Ultrasound-derived bulk strain was highly correlated with actuator-derived strain in survived (R^2 = 0.968 +/- 0.017) and ruptured tendons (R^2 = 0.972 +/- 0.014). Maximum and average longitudinal strains progressively diverged between groups across fatigue life (Group x FatigueLife: p = 0.003 and p < 0.0001, respectively). During the first 10,000 cycles, average strain decreased in survived tendons ({beta} = -0.0268%, p = 0.0215) but not ruptured tendons ({beta} = 0.0147%, p = 0.1197), with a significant Group x Cycle interaction (p = 0.0061). This study demonstrates that the algorithm quantified Achilles tendon deformation with high fidelity and enabled spatially resolved strain assessment throughout fatigue loading. Maximum and average strain followed different trajectories between groups, whereas strain heterogeneity did not. Early differences in tendon biomechanics suggest that regional strain behavior may change before pronounced differences in absolute magnitude develop.

bioengineering↗

Brain organoid computing for robotic decision-making

Biomimicry has inspired the evolution of robotics toward greater autonomy, adaptability, and symbiosis with humans and dynamic environments. However, current robotic systems still face major challenges in recapitulating the high-efficiency decision-making capabilities of the human brain under complex and dynamic conditions. Here, we present Brainobot, a biohybrid robotic system that establishes a brain organoid controller as a high-level robotic decision-making layer for closed-loop embodiment. By leveraging brain organoid reservoir computing, Brainobot interacts with dynamic environments by receiving and processing sensory inputs and generating motor actions. As a proof-of-concept demonstration, Brainobot is implemented in a humanoid robotic system to perform real-world tasks, including object grasping and laser chasing. Interestingly, Brainobot exhibits unique features, including cross-task adaptivity, high computing efficiency, and low energy consumption. Thus, our approach may provide insights for advancing robotic embodiment and understanding biological decision-making.

bioengineering↗