bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.11.04.686540

Understanding the Mechanisms Behind the Annuloplasty Effect in Tricuspid Valve TEER: A Computational Study

Abstract

BackgroundAn annuloplasty effect has been observed following tricuspid transcatheter edge-to-edge repair (TEER) and has been shown to have a therapeutic benefit. However, the mechanisms underlying the annuloplasty effect remain unknown. ObjectivesWe investigate the impact of TEER-induced annular forces on the annuloplasty effect. Additionally, we explored the impact of clip size, clip orientation, leaflet pair, and leaflet site on TEER-induced annular forces. MethodsWe simulated 36 TEER repairs in finite element models of three human tricuspid valves. We used either a NTW or XTW TriClip. The clip was placed between either the anterior-septal or anterior-posterior leaflet pairs, in either the central or near-annulus site. For each scenario, we quantified the reduction in annular area, septal-lateral (SL) diameter, and anterior-posterior (AP) diameter. We also report the total annular force, orientation of maximum annular force, total papillary muscle force, leaflet stress, and coaptation area ratio following TEER. ResultsTEER induced annular forces, which strongly predicted the annuloplasty effect as measured by reduction in annular area and SL diameter. The maximum annular force aligned with the orientation of the clip. Furthermore, XTW clips induced more annular force and leaflet stress than NTW clips. A central anterior-posterior site induced more force than a near-annulus anterior-posterior site, but showed no difference from an anterior-septal pair. ConclusionsTEER procedural parameters, such as clip size and site, strongly influence the magnitude of induced annular forces, which, in turn, correlate with the degree of annuloplasty effect.

Source connections

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Haese, C. E., Dubey, V., Mathur, M., Kreidel, F., Fuhg, J. N., Moussa, I., Timek, T., Rausch, M. K.. 2025-11-05. Understanding the Mechanisms Behind the Annuloplasty Effect in Tricuspid Valve TEER: A Computational Study. https://doi.org/10.1101/2025.11.04.686540

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

Surfactant-Assisted Colorimetric Signal Enhancement in Paper-Based Glucose Sensing

Paper-based colorimetric sensors offer a low-cost and accessible platform for point-of-care (POC) analysis, but enzyme activity loss during coating and drying can weaken analytical signals and require high enzyme loadings or complex immobilization procedures. Although surfactants are widely used to improve wettability in paper-based assays, their potential contribution to colorimetric performance beyond these effects remains unclear. Here, we investigated surfactant-assisted colorimetric signal enhancement in a glucose assay implemented on a 96-puddle paper plate (96-PPP) and identified Tween 20 as the most effective surfactant. Its effect on detection performance became more pronounced as glucose oxidase (GOx) loading decreased; at 0.1 mg/mL GOx, Tween 20 lowered the limit of detection (LoD) from 0.113 to 0.034 mg/mL (approximately 3.3-fold) over a working range of 0-5 mg/mL, despite no statistically significant change in the measured contact angle at this loading. Tween 20 had no appreciable effect on the reaction in solution but preserved 95% of the apparent reaction rate constant after drying, compared with 11% without it, and atomic force microscopy (AFM) revealed a more dispersed dried enzyme morphology on mica. Tween 20-containing sensors also showed slower signal decay during repeated wetting-drying cycles and thermal stress, retained 77% (vs 26%) of the response at 400 mM NaCl, and exhibited within-PPP and between-batch coefficients of variation (CVs) below 10% (vs 12.3-19.5%), while maintaining glucose selectivity over potentially interfering molecules. These results indicate that Tween 20 enhances paper-based glucose sensing beyond wettability, in part by retaining enzyme cascade activity during drying, although the contributions of the individual enzymes and the underlying mechanism remain to be established.

bioengineering↗

Engineering CAR-T cells to remodel the mucin-rich cancer cell glycocalyx

The dense glycocalyx of cancer cells can restrict immune-cell access to surface antigens and limit CAR-T cell activity. Here, we show that mucin density and epitope position determine how glycocalyx remodeling affects CAR-T cell recognition and killing. We identify KLK5 as a human protease that cleaves tumor-associated mucins, increases access to membrane-proximal antigens, and enhances CAR-T cell function. We then engineer CAR-T cells to display or secrete KLK5, enabling remodeling of the tumor glycocalyx during antigen recognition. KLK5-engineered CAR-T cells improved tumor control across multiple xenograft models, and KLK5-secreting MUC17 CAR-T cells produced the strongest in vivo benefit, prolonging survival compared with conventional MUC17 CAR-T cells. These findings show that CAR-T cells can be engineered to breach the mucin-rich glycocalyx while preserving accessible target epitopes.

bioengineering↗

Wall stiffening is a primary contributor to motility loss in Crohn's disease: an electromechanical modeling study

Fibrotic strictures are among the most disabling complications of Crohn's disease, permanently narrowing the bowel and impairing motility, yet no approved therapy reverses them. Chronic inflammation alters pacemaker-network coupling, smooth-muscle excitability, and calcium-dependent contractility, while fibrosis thickens the bowel wall, narrows the lumen, and changes tissue mechanics. The relative contributions of these coupled electrical, contractile, and structural alterations to motility loss remain unclear. To address this gap, we develop an integrated electromechanical finite-element framework for fibrostenosing Crohn's disease that couples a fibrosis-driven growth model with a FitzHugh-Nagumo electromechanical model. A full-factorial 25 design of experiments is used to quantify the relative effects of electrical diffusivity, excitation threshold, peak active stress, wall stiffness, and hypertrophic remodeling on cyclic lumen-volume deformation. Motility is quantified by the standard deviation of lumen volume over one contraction cycle. Within the parameter ranges examined, increased wall stiffness emerged as the dominant contributor to motility loss, followed by impaired smooth-muscle contractility. Changes in excitation threshold, hypertrophic remodeling, and electrical diffusivity produced substantially smaller effects. Pairwise interactions were small relative to the dominant main effects, indicating that the mechanisms contributed largely through their individual effects. Our findings suggest that limiting wall stiffening while preserving smooth-muscle contractile function may provide a therapeutic strategy for maintaining intestinal motility in fibrostenosing Crohn's disease.

bioengineering↗