bioRxiv Science⌕ Search

bioRxiv · 10.1101/2025.10.31.685783

Sensorimotor confidence during explicit motor adaptation

Abstract

Humans can adapt to large and sudden perturbations of sensory feedback. What multisensory and motor-execution cues are used to determine confidence in action success, and do the dynamics of confidence parallel those of ongoing sensorimotor adaptation? Participants made a slicing reach through a visual target with an unseen hand, followed by a continuous judgment of confidence in reach success. For the confidence judgment, participants adjusted the size of an arc centered on the target. Larger arcs reflected lower confidence. Points were awarded if the subsequent visual feedback was within the arc, and fewer points returned for larger arcs. This incentivized attentive reporting of confidence and minimizing feedback-target distance to maximize the score. After the confidence response, visual feedback of hand position was shown at the same distance along the reach as the target. A 20 deg rotation was applied to the feedback during the central 50 trials of a block (alternating between clockwise and counterclockwise across blocks). We used least-squares cross validation to compare four Bayesian-inference models of sensorimotor confidence using prospective cues (knowledge of motor noise and visual feedback from past performance), retrospective cues (proprioceptive measurements), or both sources of information integrated to maximize expected gain (an ideal observer) with additional parameters for learning and bias. All but one of the participants used proprioception to calculate sensorimotor confidence during motor adaptation in addition to prior information. Confidence recovered exponentially to pre-adaptation levels after the perturbation ended, but at a slower rate than motor learning. Author SummaryWe asked participants to reach to visible locations on a tablet, without being able to see their hands. We then showed them false feedback that had been rotated away from their actual hand position. This caused them to need to aim away from their intended reach direction on later trials. Confidence in their ability to have the feedback land close to the target was reduced for more trials than it took them to adapt to the rotation. To perform well, it was necessary for people to take into account their success on previous trials as well as where they sensed their hand to be positioned on the current reach.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Evans, M. H., Landy, M. S.. 2025-11-01. Sensorimotor confidence during explicit motor adaptation. https://doi.org/10.1101/2025.10.31.685783

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related preprints

A systems-level model of sleep-dependent memory-consolidation failure in neurodegeneration: the spindle-slow-oscillation decoupling cascade dissociates amyloid and tau

During non-rapid-eye-movement (NREM) sleep, the temporal coupling of cortical slow oscillations (SOs), thalamic spindles, and hippocampal sharp wave ripples drives the consolidation of declarative memories. This coupling degrades in ageing and Alzheimers disease (AD), and although A{beta} and tau leave dissociable signatures in human sleep, the mechanisms by which progressive pathology dismantles the consolidation machinery are difficult to isolate experimentally, and have not to our knowledge been reproduced in a model that can be perturbed directly. We built a systems-level model in which cortical SOs and thalamic spindles are generated by reduced oscillators, hippocampal ripples replay encoded spike sequences, and the measured per-event SO-spindle timing alignment causally gates spike-timing dependent plasticity on cortical sequence synapses. A post-sleep cued-recall test reads out consolidation. Five neurodegeneration parameters (amyloid, tau, synaptic density, GABAergic inhibition, cholinergic tone) map to dis tinct mechanisms grounded in the human and animal literature. The model reproduces graded healthy consolidation and a progressive collapse in which coupling, slow-wave power, spindle power and recall fall monotonically and the overnight memory effect flips from consolidation to net forgetting, with weak memories failing first. Scrambling SO-spindle timing while holding oscillation power fixed abolishes consolidation, establishing that coupling timing, rather than oscillation power, is what the plasticity gate depends on within the model. A{beta} and tau impair memory through orthogonal signatures (A{beta} collapses slow-wave power while sparing replay order, tau the reverse) and this orthogonality holds across the entire A{beta} x tau plane and survives simultaneous {+/-}50% resampling of every mapping coefficient (40/40 samples), so it is not an artefact of a single calibration point. The model yields a falsifiable clinical prediction: closed-loop slow-oscillation enhancement rescues memory only when the deficit is amplitude/coupling-dominated, not when it is replay(tau)-dominated, despite normalising slow-wave power in both cases. Because the therapy arms dissociate coupling from memory benefit, the model also cautions against adopting SO-spindle coupling as a standalone surrogate endpoint.

neuroscience↗

Toxicity of MAPT 4R RNA Contributes to Motor Neuron Degeneration in ALS

MAPT (Tau) dysregulation is implicated in several neurodegenerative diseases, but its contribution to amyotrophic lateral sclerosis (ALS) is poorly understood. Here we show that mRNA isoforms encoding 4-repeat (4R) Tau are upregulated and cytoplasmically enriched in iPSC-derived motor neurons (MNs) from VCP-mutant and sporadic ALS, without a corresponding change in Tau protein. Using splice-switching antisense oligonucleotides and isoform-specific siRNAs, we find that enhanced 4R expression reduces MN viability, whereas its selective knockdown improves survival, with kinetics more consistent with an RNA-intrinsic effect than altered protein synthesis. Exon 10-containing MAPT RNA shows increased predicted secondary structure, self-association and altered Tau biocondensation in vitro. In post-mortem ALS cervical spinal cord, increased relative exon 10 usage is associated with a higher-risk clinical phenotype and shorter disease duration These findings identify an isoform-specific contribution of MAPT to MN vulnerability in ALS and nominate 4R MAPT RNA as a therapeutic target.

neuroscience↗

30 Hz High-Definition Transcranial Alternating Current Stimulation at the Left Frontal Cortex Reduces the Spectral Slope of the EEG in the Contralateral Hemisphere

Background: High-definition transcranial alternating current stimulation (HD-tACS) is favored by the neurostimulation community for its precision and ability to influence neuronal dynamics. Yet, the exact mechanism by which the underlying brain structures are being affected remains unclear. We believe that the investigation of the aperiodic nature of the electroencephalograph (EEG) could shed light on the modulatory effects of HD-tACS. Methods: We analyzed the EEG of 9 participants during a compensatory tracking task (CTT) in two sessions, each with different HD-tACS protocols. Every session consisted of an initial period of no stimulation, followed by 30 Hz HD-tACS in the left motor (M30) or frontal (F30) cortex. We then isolated the aperiodic component of the EEG and calculated its spectral slope {beta}. Results and Discussion: {beta} decreased during F30 mainly in the right frontal cortex, indicating a shift towards higher frequencies and an increase of the excitatory/inhibitory balance. Additionally, we found that despite the long monotonus task the accuracy of the participants did not decrease, which might be attributed to the ability of both M30 and F30 to sustain attention for prolonged time. Finally, the change of CTT accuracy during the stimulation correlated with the {beta} of specific channels before the stimulation. This indicates the potential of {beta} to be used as a screening biomarker in future studies. In conclusion, we showed the ability of HD-tACS to alter EEG aperiodic dynamics and paved the way for future exploration of such dynamics in the field.

neuroscience↗